1. The outlet side of the Siemens inverter can not be connected in parallel to compensate the capacitor, nor can the capacitor be paralleled in order to reduce the high-order harmonics of the output voltage of the inverter, otherwise it may damage the Siemens inverter in order to reduce the harmonics. Able to connect reactors in series.
2. The start and stop of the motor with Siemens inverter (Variable-frequency Drive) speed regulation cannot be directly operated by circuit breaker and contactor, but by using the control terminal of Siemens inverter to operate, otherwise the inverter will be out of control, and may form a severe result
3. Regarding the occasion of progressive load and frequent start and stop, there will be torque, and it is necessary to select the appropriate braking resistor, otherwise the Siemens inverter will often trip due to overcurrent or overvoltage. Siemens agent innovation has become the cornerstone of Siemens' success. R&D is the basic driving force of Siemens' development strategy. As holders of key patents, we are a strong partner to our customers, whether it is an experienced process or a developing know-how. Our goal is to be the leader of skills in many of the things we are involved in.
4. It is generally not advisable to install a communication contactor between the Siemens frequency conversion device and the motor to prevent overvoltage and damage to the inverter between the current interruptions. If additional installation is required, the output contactor should be closed before the operation of the Siemens frequency converter.
5. The obstruction of the external braking resistor of the Siemens frequency conversion device cannot be less than the requirements of the braking resistor agreed by the inverter. Siemens AgentsSiemens tries to meet all legal and ethical requirements, and, as long as possible, we try to exceed them. It is our responsibility to conduct our business in accordance with the highest standards and practices of work and morality: the company will not tolerate any non-compliance. On the premise of satisfying the braking requirements, the braking resistance should be larger. Do not short the terminal that should be connected to the brake resistor directly, otherwise, a short circuit accident will occur through the switch during braking.
6. When the speed of the motor is controlled by Siemens inverter (Variable-frequency Drive), the temperature rise and noise of the motor will be higher than that when the power frequency is used; When running at low speed, due to the low speed of the motor blades, attention should be paid to ventilation and cooling and appropriate load reduction to prevent the temperature rise of the motor from exceeding the promised value. Siemens AgentsSiemens tries to meet all legal and ethical requirements, and, as long as possible, we try to exceed them. It is our responsibility to conduct our business in accordance with the highest standards and practices of work and morality: the company will not tolerate any non-compliance.
7. Do not install too large capacitors on the incoming side due to the progress of power factor, nor can you install capacitors between the motor and Siemens frequency conversion, otherwise the line impedance will decrease, produce overcurrent and damage the inverter
8. For the occasion of constant torque operation of ordinary motors driven by Siemens inverter (Driver), long-term low-speed operation should be prevented as much as possible, otherwise the heat dissipation effect of the motor will become worse and the heating will be severe. If you need to run for a long time at low speed constant torque, you must choose a variable frequency motor.
9. When the motor has another brake, the Siemens inverter should work in the free shutdown method, and the braking action signal is announced after the inverter announces the parking instruction.
10. When the three-phase voltage unbalance rate of the power grid is greater than 3%, the peak value of the input current of the Siemens inverter (Variable-frequency Drive) is very large, which will form the Siemens inverter and connect the overheating or damage to the electronic components, at this time, it is also necessary to install a communication reactor. In particular, when the transformer (air pressure variable) device is V-shaped, it is more severe, and in addition to installing a reactor on the communication side, it is also necessary to install a DC reactor on the DC side.
11. The impedance of the power supply line should not be too small. When the capacity of the distribution transformer (air pressure variable) is greater than 500KVA or the capacity of the distribution transformer is greater than 10 times of the capacity of the Siemens inverter, or when the Siemens inverter is connected to the distribution transformer very closely, due to the small impedance of the circuit, the input will produce a large surge on the Siemens inverter instantly, which will damage the rectifier element of the Siemens inverter. When the line impedance is too small, a communication reactor should be installed between the grid and the Siemens inverter.
|
More on that
|
Siemens supports the transition to sustainable infrastructure with new digital solutions
Siemens unveiled its face at the 2022 Lighting and Construction Electrical Exhibition in Frankfurt, Germany under the theme of "Smart Infrastructure Can Continue Infrastructure". During the exhibition, Siemens Essentials underlined its digital vision as the infrastructure needed to address climate change and global sustainability challenges.
|
|
Siemens released its third-quarter financial results
Siemens, as a dedicated technology company, delivered significant results in the third quarter of fiscal 2022 (ended June 30, 2022). The macroeconomic environment remains chaotic due to factors such as economic sanctions against Russia, high inflation and the coronavirus pandemic, but Siemens is still in many key malls.
|
|
Siemens presents innovative solutions at the China Refrigeration Exhibition
With the theme of "Zero-carbon Forward, Smart Space", Siemens brought its building digitalization and low-carbon products and solutions to the 33rd International Exhibition on Refrigeration, Air Conditioning, Heating, Ventilation and Food Freezing Processing (2022 China Refrigeration Exhibition), which comprehensively demonstrated Siemens' commitment to commercial buildings, ...
|
|
How to use the data block of the Siemens S7-200 SMART
How to use the data block of Siemens S7-200 SMART. Before explaining the use of data blocks, let's take a look at what data blocks are: data blocks are used to assign initial values to the V store, also called the variable store; Ability to assign data values to bytes, words, or two words.
Divide the data in a chunk ...
|
|
How to use a Siemens memory card to wipe the password or do a factory reset
If the customer forgets the password that was previously set to the S7-1200, the program and password inside the S7-1200 cannot be erased by "Factory Reset", so the only way to clear it is to use the memory card. The detailed steps are as follows:
1. Use a memory card, insert it in a computer card reader, ...
|
|
The Siemens 3RM11/3RM13 motor starters have two different protection functions
The 3RM11/3RM13 motor starters include two different protection functions.
One protection function is a safety application, and the other is an explosion protection application (ATEX).
1. Functional Safety:
Here, the purpose of protection is to identify and control dangerous conditions. In the safe ...
|
|
Siemens S7-200 SMART Analog FAQ
1. Can the S7-200 SMART Normal Analog Module connect 4-20mA signals?
Yes, the S7-200 SMART CPU analog module can detect standard current signals from 0 to 20 mA and 4 to 20 mA. Wiring of two current signals, in the STEP 7-Micro/WIN SMART ...
|
|
Siemens joins hands with Hisense to explore the home appliance industry
Siemens recently signed a strategic cooperation agreement with Hisense Group Holding Co., Ltd. (Hisense). The two sides will be based on Siemens' preemptive digital business portfolio, as well as the successful practice of digital transformation, to promote Hisense's digital construction together, and explore the development of intelligent production in the home appliance industry.
|
|
Siemens released a white paper on zero-carbon smart parks
Siemens today officially released the "Siemens China Zero Carbon Smart Park White Paper" (hereinafter referred to as the white paper), which analyzes and proposes the definition and architecture of zero carbon smart parks, the core pain points and entry points of various parks, and shares the current situation and trend of carbon peak and carbon neutrality in China and China.
|
|
Industries for which Siemens PM250 power supplies are applicable
The PM250 power modules are suitable for a wide range of applications in the field of general mechanical engineering. This module is able to feed braking energy directly back into the power supply system (four-quadrant applications, no brake chopper required).
The PM250 power module is equipped with the world's most advanced Efficient Infeed Tech...
|
|
Siemens acquires Supplyframe
Siemens recently signed a buy-in agreement to acquire Supplyframe, a leading platform for planning-to-acquisition information in the global electronics value chain, for $700 million. The sale will bring tremendous value to Supplyframe and Siemens' customers, helping them to achieve a seamless, fast and seamless process.
|
|
Siemens introduces a new generation of industrial Ethernet switches
At SPS 2022 in Nuremberg, Siemens introduced the new generation of Scalance XC-/XR-300 series Industrial Ethernet switches. With the increasing number of machines, controls and IT systems connected to the network in industrial production, the network at the production level is also ...
|
|
Siemens' CIIE kicks off the acceleration of digitalization and decarbonization
At the 5th CIIE to be held on November 5-10, Siemens will once again bring a luxury formation to the first release and display of a variety of innovative channels and services.
In the past five years, from the innovative display of product skills, the landing of career plans, to the stimulation of channels and services, the exhibition of product skills, the unveiling of career plans, and the promotion of channels and services.
|
|
Siemens will acquire FORAN entirely
Siemens will fully acquire POLLAN in October 2021 to enhance its marine planning and engineering capabilities. The FORAN business will then be integrated into the Xcelerator channel, which Siemens has been promoting in recent years. With the acquisition of FORAN, Siemens will provide the shipbuilding industry with a comprehensive software and ...
|
|
Siemens publishes a white paper on leadership
Siemens today released the Siemens Leadership China White Paper (hereinafter referred to as the "White Paper"), which combines the evolution of leadership theory and its performance in the business environment, comprehensively sorts out the development and upgrading of its own leadership methodology and its application in the course of more than 100 years, and deeply analyzes the development and upgrading of its leadership methodology and its application over the past century.
|
|
Siemens has released version 4.0 of the web-based SIMATIC PCS neo control system
Process industrial companies are faced with multiple challenges: how to accelerate digitalization, achieve sustainable development, and how to deal with the shortage of skilled personnel. At Siemens, we believe that plant managers can only cope with these challenges and prepare for the future with a highly sensitive process control system. In this cloth ...
|
|
Can two different FB blocks in OB1 run at the same time in the S7-300PLC?
1. It is impossible to be simple at the same time, and at the same time it is relative. The CPU can only run one program at a given time.
2. Understand that S7-300PLC is a cycle scan: ie
a. At the beginning of a regular cycle, the CPU performs signals such as input jobs (fill in the input image area data...)
|
|
Does the power supply cable between the Siemens soft starter and the motor need to be shielded?
For 3RW soft starters, it is sufficient to use an unshielded main loop cable between the motor and the 3RW soft starter.
The main reasons are as follows:
The frequency of the power supply on the motor terminals is stabilized at 50 or 60 Hz throughout the operation of the soft starter
After the soft start is completed, the main ...
|
|
Siemens joins hands with Chery to stimulate new momentum for the development of the automotive industry
Chery is China's leading self-owned brand car manufacturer and one of the largest passenger car exporters in China. In recent years, Chery has actively implemented the core strategy of "Digital Chery", and built an intelligent and connected "factory of the future" in Wuhu, Anhui Province, accelerating the transformation from "traditional cars" to "intelligent cars".
|
|
Siemens' Chengdu digital factory and high-performance permanent magnet synchronous motors have been certified as "carbon neutral".
During the CIIE, Siemens Industry Automation Products (Chengdu) Co., Ltd. (hereinafter referred to as Siemens Chengdu Digital Factory) obtained the "Carbon Neutrality Achievement Verification Statement" issued by TÜV SÜD (hereinafter referred to as TÜV SÜD), which means that it has successfully passed the "Carbon Neutrality Achievement Statement".
|
|