How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings

Create Date: 2024-8-30 12:03:23|Source: Siemens/Siemens

You can reset your S7-1200 to factory settings using an empty SIMATIC MC memory card.
How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings

illustrate

Even if you don't have SIMATIC STEP 7 Basic software and don't know the IP address, you can use the SIMATIC MC memory card to remove the IP address and reset the S7-1200 to factory settings (including firmware V2.1.2).

Disable Write Protection Make sure that the memory card is not write-protected. To do this, you move the protection switch out of the locked position.

Use an empty memory card There are two ways to get an empty memory card.

Use a new, empty SIMATIC MC memory card from Siemens.

If your SIMATIC MC memory card is not empty, delete the SIMATIC. S7S" folder and "S7_JOB. S7S" file, e.g. using Windows Explorer.

How to delete an IP address

Follow the steps below to remove the IP address and reset your S7-1200 to factory settings, including firmware V2.1.2.

1. Insert an empty memory card in your S7-1200.

2. Turn the S7-1200 off and back on.

This will reboot the S7-1200. After rebooting and re-evaluating the SIMATIC MC memory card and load memory, this means that the device configuration, including IP addresses, user programs, and all force values, is copied to the memory card. The memory card becomes a program card that contains the data and IP address that were previously stored in the internal load memory. Once the replication process is complete, the S7-1200's internal loading memory will be removed. The S7-1200 now switches to the configured operating mode to start (run or stop).

Once the process is complete, the S7-1200's service light will flash indicating that you can remove the memory card.

3. Remove the memory card from the S7-1200.

4. Turn the S7-1200 off and back on.

The internal load memory including the IP address has now been removed and the S7-1200 to firmware V2.1.2 have been reset to factory settings.

More on that
SIMATIC S7-1200 compact CPU SIMATIC S7-1200 compact CPU

Installation 1. Remove the backplane bus cover 2. Insert the SM onto the standard mounting rail 3. Push the SM to the adjacent module 4. Lock the standard rail mounting clip 5. Push the latch used to connect the bus connector to the left so that the bus pin is connected to the adjacent module ...

Siemens and LONGi Green Energy have carried out in-depth cooperation Siemens and LONGi Green Energy have carried out in-depth cooperation

Founded in 2000, LONGi Green Energy has built five business segments: monocrystalline silicon wafers, cell modules, industrial and commercial distributed solutions, green power solutions, and hydrogen energy equipment, constituting "green electricity" + "green hydrogen" products and solutions that support global zero-carbon development. In November 2022, the ...

Siemens s7-200 SMART interrupt command Siemens s7-200 SMART interrupt command

The S7-200 SMART series of programmable controllers has up to 38 interrupt sources (9 reserved), which are divided into three categories: communication interrupts, input/output (I/O) interrupts, and time-based interrupts.

How do I set up the IP forwarding function in order to configure IO-Link master using S7-PCT via the interface of the S7 CPU? How do I set up the IP forwarding function in order to configure IO-Link master using S7-PCT via the interface of the S7 CPU?

IP forwarding refers to the ability for a device to forward IP packets between two connected IP subnets. You can enable or disable IP forwarding in STEP 7. If IP forwarding is enabled, the S7-1500 CPU forwards received IP packets from non-CPU addresses to the local IP subnet.

Siemens S7-1200 series frequently asked questions about formulation functions Siemens S7-1200 series frequently asked questions about formulation functions

1.Do all CPUs in the S7-1200 series support recipe functions? The CPU version of the S7-1200 is V4.0 or later, and recipe function instructions are supported. HOWEVER, THE FUNCTION OF THE FORMULA IN A BROAD SENSE, FROM THE TIA PORTAL V11 SP2, S7-1200 V2.0 FIRMWARE VERSION ...

Common problems with the S7-200 SMART high-speed counter Common problems with the S7-200 SMART high-speed counter

Why does assigning initial and preset values to a high-speed counter not work, or the effect is unexpected? The high-speed counter can be initialized or changed during operation, such as initial values and preset values. The procedure should be: Set update options for control bytes. Need...

Siemens Electrical Products China and East Asia headquarters were inaugurated in Suzhou Siemens Electrical Products China and East Asia headquarters were inaugurated in Suzhou

Foreign investment continued to increase and deeply cultivated the layout of Gusu. On July 5, Siemens Electric Products officially unveiled its headquarters in China and East Asia, and signed a deepening strategic cooperation agreement with Gusu High-tech Zone. Wu Qingwen, deputy secretary of the municipal party committee and mayor, attended the event and unveiled the plaque; Executive Vice President of Siemens, Siemens China ...

Siemens joins hands with Jingyuntong to promote the high-quality development of the photovoltaic industry Siemens joins hands with Jingyuntong to promote the high-quality development of the photovoltaic industry

Siemens and Beijing Jingyuntong Technology Co., Ltd. ("Jingyuntong") recently signed a strategic cooperation agreement. Based on Siemens' advanced automation and digital solutions, the two sides will open up cooperation in the development and production of high-end photovoltaic equipment, and jointly promote the high-tech development of the new energy photovoltaic industry.

A few points of Siemens 1500, 1200 motion control summary 1500T and ordinary 1500CPU A few points of Siemens 1500, 1200 motion control summary 1500T and ordinary 1500CPU

With the update of Siemens 1500 CPU firmware version, the function of motion is getting stronger and stronger, this article takes the firmware version of V2.5 and above as the foundation, and briefly summarizes a few questions. First of all, the 1500T is fully compatible with all the functions of the 1500CPU. T CPU is the base of the general CPU to enhance the movement ...

The S7-300/400 communicates with SINAMICS S120 via the DP bus The S7-300/400 communicates with SINAMICS S120 via the DP bus

1. Overview of DP bus communication function S7-300/400 and SINAMICS S120 can carry out periodic and non-periodic data communication through DP bus. Using the standard S7 function block SFC14/SFC15, the S7-300/400PLC can change the control word 1 (CTW1) ...

Siemens' Industrial IoT Convergence Application Competence Center was established in Baoding Siemens' Industrial IoT Convergence Application Competence Center was established in Baoding

Siemens today signed a strategic cooperation agreement with the Management Committee of Hebei Baoding Industrial Park and Hebei Shenbao Investment Development Co., Ltd. Based on the digital skills innovation effect developed by Siemens' local team in China, the three parties will jointly build a Siemens Industrial Internet of Things integration in Baoding Industrial Park.

Daimler Trucks and Siemens have partnered to build a digital integrated engineering platform Daimler Trucks and Siemens have partnered to build a digital integrated engineering platform

Siemens Digital Industries and Daimler Trucks have announced a new collaboration to leverage Siemens Xcelerator industrial software and services portfolio to build an advanced digital engineering pipeline. The channel will enable Daimler Trucks to explore the innovations of commercial vehicles.

Siemens SIMATIC S7-1200 PLC hardware composition and its characteristics Siemens SIMATIC S7-1200 PLC hardware composition and its characteristics

SIMATIC S7-1200 PLC The S7-1200 series is a Programmable Logic Controller (PLC) that can control a wide range of automation applications. The S7-1200 has a compact design, low cost, and a powerful instruction set.

Update the firmware version of your S7-1200 CPU with a 24M memory card Update the firmware version of your S7-1200 CPU with a 24M memory card

1. Use your computer to erase the contents of the memory card through a card reader. Note: Do not format the memory card! 2. Download the latest version of the firmware file from the official website of Siemens. After downloading and unzipping, you can get a "S7_JOB.SYS" file and a "FWUOPDATE. S7S ...

Siemens loads the item to a memory card in transfer mode Siemens loads the item to a memory card in transfer mode

Mount items to a memory card in transfer mode Step 1: Follow the above method to set the memory card to "Transfer Card" mode. Customers are advised to clear all files from the memory card before doing this. Step 2: Set the boot state of the CPU: In the "Project ...

Industries for which Siemens PM250 power supplies are applicable Industries for which Siemens PM250 power supplies are applicable

The PM250 power modules are suitable for a wide range of applications in the field of general mechanical engineering. This module is able to feed braking energy directly back into the power supply system (four-quadrant applications, no brake chopper required). The PM250 power module is equipped with the world's most advanced Efficient Infeed Tech...

Siemens joins hands with Hisense to explore the home appliance industry Siemens joins hands with Hisense to explore the home appliance industry

Siemens recently signed a strategic cooperation agreement with Hisense Group Holding Co., Ltd. (Hisense). The two sides will be based on Siemens' preemptive digital business portfolio, as well as the successful practice of digital transformation, to promote Hisense's digital construction together, and explore the development of intelligent production in the home appliance industry.

Siemens is investing 600 million euros in an industrial and technological center in Berlin Siemens is investing 600 million euros in an industrial and technological center in Berlin

Sept. 16 (Reuters) -- Siemens returned to its headquarters in Berlin on Wednesday to announce plans to invest 600 million euros ($681 million) in an industrial and technological center in Germany's capital. This investment will contribute to the creation of a new Siemensstadt in the Berlin area, the predecessor of Siemens ...

Siemens S7-200 SMART Digital I/O Wiring FAQ Siemens S7-200 SMART Digital I/O Wiring FAQ

1. Can the digital input of the same module be connected to NPN and PNP signals at the same time? No, because the two types of signals NPN and PNP are in the opposite direction of the current at the DI point in the loop formed by the DI terminal, and similarly the current direction at the M point is also opposite, as shown in Figure 7 and Fig.

Some reasons why Siemens motor motors heat up Some reasons why Siemens motor motors heat up

The motor is an energy conversion mechanism, and some losses will inevitably occur in the process of energy conversion, and most of these losses will be turned into heat dissipation, which will increase the temperature of the motor. Excessive temperatures can lead to a shortened life of certain motor components, which can eventually lead to failures. Motor...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top