First, the inverter is not repaired and the power test is tested
(1) Inverter repair test rectifier circuit
At the two ends of the inverter to detect the internal DC power supply, P and N ends, adjust the multimeter to the resistance RX10 gear, the red watch pen is connected to the P end, and the black watch pen is connected to R, S, T in turn, there are tens of ohms of resistance in normal times, and the basic balance, on the contrary, the black watch pen is connected to the P end, and the red watch pen is connected to R, S, T in turn, there is a resistance value close to infinity, the red watch pen is connected to the N end, and the above process is repeated, and the results are consistent.
If there are the following three results, it can be determined that the inverter repair circuit has been abnormal. (1) The resistance value of the three-phase is unbalanced, which indicates that there is something wrong with the rectifier bridge. (2) When the red watch pen is connected to the P terminal or the black watch pen is connected to the N terminal, the resistance is infinite, and the rectifier bridge or dynamic resistance can be determined. (3) When the red watch pen is connected to the P terminal or the black watch pen is connected to the N terminal, the resistance is close to zero, and the rectifier bridge short circuit fault can be determined.
(2) Inverter repair test inverter circuit
Connect the red watch pen to the P end, the black watch pen is separated from the U, V, W, there should be tens of ohm resistance, and the resistance value of each phase is similar, the reverse phase should be infinity, the black watch pen is connected to the N end, repeat the above process should get consistent results, otherwise it can be admitted that there is a problem with the road change module.
Second, the inverter repair and power-on test status
After the uncharged test, the rectifier circuit and the inverter circuit have no problems, and then the inverter repair is powered on the test, and the following points must be paid attention to before and after power-on:
(1) Before powering on, you must admit whether the input voltage is wrong, and the 380V power supply will be fried (fried capacitors, varistors, modules, etc.) when the input voltage is mistakenly connected to the 220V transformer.
(2) Check whether the plug-in interface of the inverter repair has been correctly connected, whether the connection is loose, abnormal connection may sometimes lead to the inverter to show problems, and when it is severe, it will appear to blow up the machine.
(3) After powering on, detect the content of the fault, and start to determine the fault and the cause.
(4) If there is no problem, first check whether the parameters are abnormal, and after the parameters are restored, start the inverter under the condition of no load (not connected to the motor), and test the output voltage value of U, V and W If the three-phase output voltage value is missing and unbalanced, there is something wrong with the module or drive board.
(5) Under the condition that the output voltage is normal (no phase loss, three-phase balance), the negative test should be a full load test as much as possible.
|
More on that
|
The method of heat dissipation of small-capacity inverter - Sunland inverter
Natural heat dissipation methods are generally used for heat dissipation of small-capacity inverters, because their operating environment should be well ventilated and free of dust and floating objects. The drag targets of such inverters are mostly household air conditioners, CNC machine tools, etc., and the power is small.
Still...
|
|
Inverter line control mode - Senlan inverter
Each inverter (Variable-frequency Drive, VFD) is subject to different line control, and the methods of voltage control and current control can be divided into two categories, one is voltage type and the other is current type. The control mode can also be divided into voltage control and current type. The main circuit method and ...
|
|
Sunland - inverter operation process and factory value restoration
The general operation process is as follows:
Enter the program through the operation panel and set the parameters, and set the relevant parameter groups such as the start-stop method, operation and control form according to the requirements of the industrial control. After confirming that the wiring is correct, the no-load power on test run and ...
|
|
What should I do if I forget the password?
With the passing of time, the inverter has now fully penetrated into the work of major industries. In our daily use, we will inevitably encounter all kinds of problems. For example, I forgot the cipher code of the inverter.
See here ...
|
|
Application of Sunland inverter on gantry milling machine
The gantry milling machine is a machining equipment for processing larger workpieces, and its electrical control system includes two parts: the main transmission of the workbench and the logical control of the feed organization. Henan Jiaozuo Maike Company has a gantry milling machine, which has been used for many years since the 70s. The main drive of the operating table of the gantry milling machine is selected ...
|
|
The connection method of three-phase isolation transformer - Senland
The three-phase barrier transformer adopts a three-phase double-winding structure, which has the characteristics of lightning protection and anti-disturbance. Each winding on the primary and secondary sides is divided into two coils, which are wound from two layers of metal foil insulated from each other. So there is capacitance C (capacitance barrier transformer) between the two coils. Then, being able to ...
|
|
Solve the inverter fault method - Sunland inverter
Motherboard faults are often manifested as faults that are difficult to visually identify, such as system startup failure and screen invisibility.
You can use a brush to gently brush off the dust on the motherboard, in addition, some plug-in cards and chips on the motherboard are in the form of plugs.
|
|
Inverter remote control wiring method - Senlan
1. Connect X (switching input) drive terminal to control the inverter start-stop/forward and reverse rotation;
2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control active conditioning frequency)
3. Other DO (switching output) is used for transmission ...
|
|
Sunland SB200 37KW inverter does not show analysis
After inspection, the circuit board of the machine is composed of a fan switching power supply board, a control board with a switching power supply and a driving board, etc., the fan power supply and the control board working power supply are independent of each other, the fan power supply output is normal, and the control board working power supply has no output due to failure.
...
|
|
The difference between Sunland inverter and soft starter
What is a frequency converter?
The inverter is a converter that converts the communication electricity with fixed voltage and frequency into the communication electricity with variable voltage and frequency, which is called the inverter. It is mainly used in the local demand for speed regulation, and its output not only changes the voltage but also changes the frequency together; The soft engine is really ...
|
|
Senlan low-voltage inverter has four series of applications
1.SB200 fan pump special inverter, widely used in textile, printing and dyeing, washing, cable, packaging, machinery, ceramics, constant pressure water supply, constant temperature control or various OEM.
2.HG1000 high-performance light-load intelligent inverter ...
|
|
Sunland inverter soft start advantages
Sunland inverter and soft start is a first-class, reliable and reliable motor control system, which is able to meet the needs of various applications. The advantages of expected Sunland inverters and soft start are:
1. Performance: Expect Sunland inverter and soft start...
|
|
Quickly determine whether the inverter used is suitable - Sunland inverter
First of all, we need to understand a truth, that is, many times the good and bad of things are relative. The variable frequency drive (VFD) is used as a power source to drive the operation of the motor, and its fundamental role is to regulate the speed. If the wiring is normal, the parameters are reasonable, and the load is not ...
|
|
Energy-saving operation method of air compressor inverter - Senland
At present, the domestic air compressor market takes the goal of energy saving, environmental protection and cost reduction as the primary demand, and the new products developed are very popular. However, economically speaking, it cannot completely replace the conventional screw air compressor with large area and large capacity in use. Therefore, the use of inverter technology to ...
|
|
The inverter has an overvoltage phenomenon - Sunland inverter
Inverters often encounter a variety of problems during commissioning and use, during which overvoltage is the most common. After the overvoltage occurs, in order to avoid damage to the internal circuit, the overvoltage protection function of the inverter will work, so that the inverter will operate intermittently, resulting in the equipment can not be ...
|
|
Sunland inverter is used in Baotou steel water supply
In recent years, with the development of power electronics skills, the frequency conversion speed regulation skills have been very mature, practice has proved that the use of frequency conversion speed regulation in fans, pumps and loads can save 20%-50% of the electric energy, and the use of frequency conversion speed regulation can bring the following advantages in the future, its biggest advantage is that it has ...
|
|
Application of Sunland inverter in sugar separator
First, the operation of the machine before the technical transformation
The sugar separation process of a sugar factory in Yunnan uses centrifugal dehydration method. The separation machine is mainly composed of a cone drum and a drive motor, and the motor shaft is directly connected to the bowl. Solid sugar crystallized from a high concentration of sugar water, in a cone bowl ...
|
|
Inverter protection and braking force issues – Sunland
1. What is regenerative braking?
If the motor decreases the command frequency during operation, the motor becomes an asynchronous generator and works as a brake, which is called regenerative (electrical) braking.
2. Can you get more braking power?
Regenerated from the motor ...
|
|
Ensure the normal operation of the inverter in a humid environment
Due to the heavy rain and humidity in some areas recently, in order to avoid long-term power failure and the impact of wetting on the inverter, the following points can be used as various precautions before customers resume production:
1. Look inside the electrical cabinet, e.g. ...
|
|
The remote control of the inverter meets the function - Sunland inverter
In general, the long-distance operation of the frequency converter requires the following functions:
1) Long-distance setting, if the parameters only need to be set for the first time, and do not need to be adjusted during operation, then long-distance setting is not required.
2) Long-distance start-stop, long-distance start or stop inverter, and ...
|
|