1. The optical power meter is not accurate, the domestic optical power meter can only test the equipment with small optical power output, and cannot test the EDFA with high power output, and the optical power meter of the optical amplifier must be imported originally, and the inaccurate instrument can not be used as a standard.
2. The flange of the output port is damaged, which is less likely.
3. The user improperly uses the pigtail, plugs and unplugs the pigtail when the machine is working, burns the pigtail head output by the optical amplifier, and forms a decrease in the output power of the optical amplifier.
4. The quality of the pigtail used by the user is too poor, the fiber core is too long, and the output connector of the optical amplifier is scratched after inserting the pigtail, this phenomenon is good for the first test, and the optical power decreases when the second time is inserted and tested again, and the output connector of the optical amplifier is only needed to be welded from scratch to deal with this problem.
5. The wavelength of the light source is wrong, if the wavelength of the 1550nm optical transmitter is incorrect, the output optical power of the optical amplifier will be insufficient, and the panel will be small.
6. The optical power of the input optical amplifier is small, and if it is lower than the standard value, the optical power may become smaller, and the panel display will also become smaller.
|
More on that
|
What are the main application areas of Omron relays?
In terms of application fields, Omron relays can be used in the following fields:
1) Home appliance market
Representative models: G5Q, G2RL, G5NB, G4A and other power relays
2) Medical market
Representative models: G6J-Y, G6S, G6K and other signal relays
...
|
|
The technical cooperation exchange between Omron and Sanhua was held in Hangzhou
Recently, Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") and Sanhua Holding Group Co., Ltd. (hereinafter referred to as "Sanhua") held a technical cooperation exchange meeting in Hangzhou. Nearly 100 senior leaders and technical experts from Omron, Sanhua and its subsidiaries attended the meeting.
...
|
|
Omron PLC--C200HE/C200HG/C200HX series product model
1. C200HE-CPU11-E CPU unit memory 3.2K maximum I/O points: 640 points
2. C200HE-CPU32-E CPU unit memory 7.2K maximum I/O points: 880 points
3. C200HE-CPU42-E CPU unit RAM 7.2K Max I/O points: 880 points with RS232C ...
|
|
Omron's non-contact temperature sensors bring convenience to work and life
In recent years, Omron has launched MEMS non-contact temperature sensors, and the technology incorporated into them has gradually presented the future of smart life in front of our eyes. Next, let's learn more about Omron's MEMS contactless sensor, and deeply feel the future of work and life.
|
|
The reason why the ER light is always on after the Omron PLC is powered on
1. Fault phenomenon: The ERR light is always on when the PLC is powered on, and the PLC is not working.
2. Cause of failure:
(1) Poor use environment leads to oxidation and corrosion of internal MPU, memory, and even substrates.
(2) Due to electromagnetic interference, noise interference, static electricity, etc., the internal MPU ...
|
|
Omron switch - 9 tests and methods for switching power supplies
1. Repeated short-circuit test
◆ Test instructions
The output of the module is short-circuited in various input and output states, the module should be able to achieve protection or retraction, repeated short-circuits, and after troubleshooting, the module should be able to automatically resume normal operation.
◆ Test Method
a ...
|
|
Analysis of the causes of Omron S8 series switching power supply failures
1. Fault phenomenon: After powering on, the power supply does not respond.
2. Cause of failure:
(1) The input power supply voltage is insufficient and does not reach the specified range.
(2) The input power supply voltage is instantaneously impulsed, resulting in damage to the input components (such as fuses, rectifications, etc.) as shown in the figure: ...
|
|
Omron's new product [Miniature Connector Terminal Block XW2K Series] was officially released
In May 2022, Omron Automation (China) Co., Ltd.'s new product [Miniature Connector Terminal Block XW2K Series] was officially released. The more compact size saves space in the control cabinet, reduces the number of man-hours, and gives the control cabinet a new value!
When it comes to the space footprint of the control cabinet, do you ...
|
|
Omron achieves its goal of increasing its share of the local healthcare market
Omron Asia Pacific Ltd. Philippines signed an agreement with Metro Drug Inc., a pharmaceutical sales and distribution company, to expand its distribution network for OMRON Healthcare Philippines' blood pressure monitors, nebulizers, thermometers, body composition monitors, and TENS massagers ...
|
|
What is the main role of Omron micro switches in household appliances?
There are 3 types of micro switches, which perfectly match the precise control needs of household appliances
Micro switch refers to a contact mechanism with a small contact spacing and a snap-action mechanism, a contact mechanism that carries out the switch action with a specified stroke and a specified force, covered with a shell, and a drive rod on its outside, ...
|
|
Causes and solutions for E2 fault codes on Omron electronic sphygmomanometers
The E2 fault code usually appears on the display of the blood pressure monitor and indicates that the inflation pressure is too high or too low. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check whether the cuff is worn correctly and whether it is properly tightened.
...
|
|
Omron PLC formatting method
1. Click [Controller] - [Mode] - [Programming Mode].
2. Click [Yes] in the pop-up window, and at this time, the PLC is in programming mode.
3. Click [Controller] - [Clear All Memory].
4. Click [OK], and the PLC memory is successfully ...
|
|
Omron alarm code analysis
Warning display
Over Torque Detection (OL2)
FUNCTION code error (CE01)
Registers NO. Error (CE02)
Data Error (CE03)
Slave Execution Error (CE04)
Slave Execution (CE06)
Communication Timeout (CE10)
Display...
|
|
The working principle and purpose of Omron relays
How it works
Add a certain voltage at both ends of the coil, a certain current will flow through the coil, thus producing an electromagnetic effect, and the armature will overcome the tensile force of the return spring under the action of electromagnetic force attraction and attract to the core, thereby driving the dynamic contact and static contact (normally open contact) of the armature ...
|
|
Fault repair of Omron blood pressure monitor
1. Mercury leakage
1. The cause of mercury leakage failure
Under normal circumstances, the sphygmomanometer will often leak mercury, which may eventually cause a certain error in the measurement value of the sphygmomanometer device. Then the cause of this malfunction is generally manifested as the blood ...
|
|
Omron brought a variety of new blood pressure monitors to the Expo
Hypertension is the main risk factor for cardiovascular and cerebrovascular diseases, and is known as the "invisible killer of human health". The Lancet study shows that the number of hypertensive adults aged 30-79 has increased from 650 million to 1.28 billion in the past 30 years. In China, hypertension is also a cardiovascular disease.
|
|
Wiring method of Omron PLC
The connection method is as follows: the brown wire is connected to the PLC input point, the PLC com point is connected to the positive pole of the power supply, and the negative pole of the power supply is connected to the blue wire.
NPN type: brown is connected to the positive power supply, blue is connected to the negative power supply, the black wire is connected to the PLC input point, and the PLC com point is connected to the positive power supply. NPN is a leak type, and the detected object ...
|
|
Omron set off a digital low-carbon boom at the expo
From November 5th to 10th, the 5th China International Import Expo was held in Shanghai, where multinational companies from all over the world gathered to participate in the annual international economic and trade event.
As a global expert in digital transformation in the field of automation, Omron has entered the ...
|
|
Omron PLC serial port communication protocol
There are two simpler ways to communicate:
1. Through serial port communication, CP1W-CIF01, that is, RS232 serial port option board is installed on the two CPUs respectively, and simple communication is achieved through PCLink protocol without programming;
2. Through network port communication, CP1H installs CP1W-CIF41 network port option board ...
|
|
Powerful use of Omron color sensor-B5WC in industrial automation
With the rapid development of modern industrial production, automation has become an inevitable development trend, in the past production process, the human eye recognition color is not only too slow, but also requires high time cost and labor cost, has been unable to meet the needs of automated industrial production, so more and more ...
|
|