One. Omron switch in daily use, basically need to be used every day, when using Omron switch, you need to pay attention to do not wet hand operation, to avoid electric shock accidents, and secondly, if the water vapor invades the inside of the switch line, it will cause internal damage to the switch, such as the fault phenomenon of short circuit, so pay attention to safety in daily operation, remember not to touch the micro switch with wet hands.
Two. Regularly maintain the Omron switch, because once the switch has been used for a long time, over time it will invade some dust or abnormality, if it is not cleaned for a long time, it will reduce the performance of the Omron switch. Moreover, through the process of maintenance, the potential hidden dangers of the switch can be found, and corresponding measures can be taken to deal with it in time to ensure the normal use of the Omron switch, so it is necessary to do a good job in the daily maintenance and cleaning of the Omron switch.
Three. In the use of Omron switches, we can find that the switch key is convex and cannot be pressed, which is mainly caused by the internal switch and the shrapnel is damaged due to too much external force, resulting in the key convexity. Therefore, when using, do not press the key switch too hard, so as not to affect the life of the Omron switch.
Four. Omron switch keys do not respond and do not act, generally because the Omron switch used is exposed to the air for a long time, resulting in the phenomenon of oxidation of the shrapnel inside the Omron switch, which affects the use effect of the switch and brings inconvenience to the operation. Especially when the switch is used in humid weather, it makes the ohm switch react, so it is necessary to pay special attention to the daily drying treatment of the Omron switch, and pay attention to the dryness and ventilation of the installation environment.
|
More on that
|
Application of Omron automatic gluing robot
Process introduction
Since the implementation of the [plastic restriction order] in 2007, plastic packaging has been greatly restricted. Subsequently, all kinds of metal cans represented by beer cans, tea cans, and oil cans are increasing, and metal packaging has begun to usher in a period of rapid development.
Metal cans are divided into ...
|
|
The main features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
How to choose Omron relays?
1. Select the rated working current of the electromagnetic relay coil: For the DC electromagnetic relay driven by transistors or integrated circuits, the rated working current of the coil (generally 2 times the suction current) should be within the output current range of the driving circuit.
2. Select electromagnetic relay contact ...
|
|
Omron PLC troubleshooting
1. Power check:
The first thing to analyze is the reliability of the power supply and ground of the Omron PLC. Visually inspect power and ground cables for damaged, corroded, or other suspicious links.
Power supplies can also be electrically tested. If there is AC power in the PLC processor, test ...
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
Omron PLC--C200HE/C200HG/C200HX series product model
1. C200HE-CPU11-E CPU unit memory 3.2K maximum I/O points: 640 points
2. C200HE-CPU32-E CPU unit memory 7.2K maximum I/O points: 880 points
3. C200HE-CPU42-E CPU unit RAM 7.2K Max I/O points: 880 points with RS232C ...
|
|
Introduction to the function of Omron PLC DIP switch
1. Address setting: The DIP switch can set the local address of the PLC for communication with other devices.
2. Communication parameter setting: The DIP switch can set the communication parameters of the PLC, including communication rate, data bit, check bit and stop bit, etc.
3. Input/Output ...
|
|
What's the deal with Omron PLC without output voltage?
1. The indicator light at the output of the PLC is on, indicating that the DO point of the PLC has been closed; 、
2. The DO point of PLC is equivalent to a dry contact switch, imagine that an on/off switch on a line is closed, if you measure the voltage on both sides of this switch, there will be no voltage, thinking that the switch itself ...
|
|
How to add SMC module to Omron plc
After adding the I/O module, you need to set it in the CX-PROGRAMMER program.
Find the IO table and unit settings, double-click to find the mainframe [0000], dot + sign, and then double-click 00 (if not set), 00 represents the module number closest to the CPU.
|
|
What's going on if Omron PLC can't be installed?
1. Open the CX-programmer software;
2. Use rs232 and other communication lines to connect to PLC;
3. Open "PLC" -> "Auto Online"; - >> "Direct Online";
4. Select "Connection Type" and click "Connection".
5. In the pop-up window, click ...
|
|
Omron's non-contact temperature sensors bring convenience to work and life
In recent years, Omron has launched MEMS non-contact temperature sensors, and the technology incorporated into them has gradually presented the future of smart life in front of our eyes. Next, let's learn more about Omron's MEMS contactless sensor, and deeply feel the future of work and life.
|
|
Omron applications in semiconductor wire bonding equipment
Process introduction
High-purity gold wire (Au), copper wire (Cu) or aluminum wire (Al) is used to connect the Pad and Lead by soldering.
■ PAD is the external contact point of the circuit on the chip
■ Lead is the connection point on the Lead Frame.
W/B is the encapsulation process ...
|
|
Omron's new [Programmable Controller CP2E-ECT] was officially released
In December 2022, Omron Automation (China) Co., Ltd.'s new product [Programmable Controller CP2E-ECT] was officially released. The product is based on Omron's full research on the equipment needs of OEM customers in China, and is independently developed and produced by Omron China.
|
|
FAQs on Omron PLC
1.How to install the USB driver of CP1H?
The computer is connected to CP1H (powered on) through a USB cable, and the PC will automatically prompt to find the new hardware and prompt to install the driver.
2.The built-in USB port of CP1H can be used ...
|
|
What are some common troubleshooting methods for Omron?
(1) Failure of peripheral circuit components
This kind of failure is more common in PLC maintenance, and it is generally a frequent occurrence in failures after a certain period of work. In the PLC control loop, if there is a component damage fault, the PLC control system will immediately and automatically stop working. The input circuit is P...
|
|
Omron micro switch and model introduction
The micro switch is a contact mechanism with a small contact spacing and a quick action mechanism, with the specified stroke and the specified force for the switch action, covered with a shell, and a switch with a driving rod outside, because the contact spacing of the switch is relatively small, so it is called a micro switch, also known as a sensitive switch.
...
|
|
Instructions for the incorrect operation of Omron micro switches
Operation point one
During the installation and operation of Omron micro switches, please remember that the direction of action of the operating mechanism of the switch cannot be reversed, otherwise it is easy to cause the fault of the line. Moreover, the position of the switch should meet the requirements of the control circuit and ensure reliable operation. For micro ...
|
|
How to classify Omron signal relays?
1. Classified according to the principle of action
The electromagnetic relay drives the armature and the movable part to act through the suction generated by the current in the relay coil in the electromagnet and changes the working state of the contact system. Such as DC stepless relays, DC polarized relays, AC relays, binary differential relays...
|
|
Omron Releases G7L-X PCB Power Relays with Higher Performance and Reliability
With the acceleration of global decarbonization, sustainable energy is increasingly becoming the focus of attention. At the same time, the sharp rise in global energy prices has further promoted the rapid growth of the residential photovoltaic market, and the market has begun to pay attention to the huge potential of photovoltaic power supply systems.
|
|
Omron and Inner Mongolia National University Pharmacy jointly built MMC Health Convenience Store
Recently, Omron and Inner Mongolia Guoda Pharmacy jointly built the first MMC health convenience store in Hohhot. The strong alliance in the field of health care aims to actively respond to the policy requirements of the national "new medical infrastructure", help the standardization of chronic disease services in offline stores, and make ...
|
|