Delixi contactor common faults

Create Date: 2024-8-30 12:03:23|Source: Delixi

After long-term use or too frequent movements, or improper daily maintenance, problems may occur during operation and affect the normal operation. Frequently asked questions are as follows:

                            Delixi contactor common faults

1. Coil problem

The first problem with the coil is that the current passing through it is too large to overheat and burn out. The reason for excessive current is usually that the coil insulation is damaged, or the inter-turn short circuit or collision is caused by mechanical damage, or because the power supply voltage is too low, and the dynamic and static iron cores are not tightly touched, which will make the coil current too large, the coil is overheated and burned.

2. Contact phase breakage

Because the contact of a certain phase is not well touched or the connecting screw is loose, the motor runs out of phase. At this moment, although the motor can rotate, it announces a "buzzing" sound, and if this situation occurs, it should be parked immediately for maintenance.

3. Contact fusion welding

Press the "stop" button, the motor can not stop, and some also announce a "buzzing" sound. This kind of problem is due to the high operating frequency of the toucher, overload use, short circuit on the load side, etc., which makes the two-phase or three-phase contact cause fusion welding due to the large overload current.

4. Phase-to-phase short circuit

The forward and reverse interlocking of the toucher fails, or the two touchers are put into operation at the same time due to malfunction, resulting in a phase short circuit; Or because the toucher moves too fast, the arc short circuit is announced during the conversion process.

5. Maintenance

Check the working status of each part of the toucher regularly; The movable part of the toucher should not be stuck, the activity should be sensitive, and the sturdy parts should not be loose; The surface part of the contact and the iron core should be kept clean, and if there is grease, it should be cleaned in time. When the contact is seriously worn, it should be replaced in time.

More on that
Installation steps of motor protector - Delixi Installation steps of motor protector - Delixi

1. According to the requirements of the device part and the needs of the maintenance function, reasonably select the motor maintainer model and its various maintenance action parameter settings; 2. According to the requirements of the product operation manual, the correct device should be connected correctly according to the use of each terminal, and the operating power supply should be connected to the control ...

Instrumentation overhaul method - Delixi Instrumentation overhaul method - Delixi

Contrasting method The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.

What are the advantages of Delixi inverter What are the advantages of Delixi inverter

(1) Optimize electrical equipment: when the motor is started, there is no large current impact, and the load of the transformer is reduced. (2) The energy-saving effect is obvious: it can reach 20%-45%. (3) Extend the life of the whole machine: it has the function of soft start, reducing the load ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

Delixi linear and switching regulators introduced Delixi linear and switching regulators introduced

01. What is a linear voltage regulator? A linear regulator uses a transistor or FET operating in its linear region to subtract the excess voltage from the input voltage of the application to produce a conditioned output voltage. The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...

Delixi 2P circuit breaker selection introduction Delixi 2P circuit breaker selection introduction

When selecting Delixi 2P circuit breaker, the need is selected according to the additional voltage, additional current and operating environment of the practice circuit. The following are the main series of Delixi 2P circuit breaker and its application scenarios: DZ47s-63 2p Small ...

Delixi inverter load type Delixi inverter load type

The correct choice of Delixi inverter is very critical to the normal operation of the control system. When selecting a frequency converter, it is necessary to fully understand the load characteristics driven by the frequency converter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan, water pump ...

Delixi inverter analog output fault analysis Delixi inverter analog output fault analysis

The analog output of Delixi inverter is abnormal, and the operating frequency of the inverter does not match the output of the controller? Solution(s): First, you should determine what hardware is going wrong. Make the controller enter the manual debugging situation, respectively...

The advantages of the practical application of the inverter - Delixi The advantages of the practical application of the inverter - Delixi

With the continuous progress of industrial automation, inverters have also been widely used, energy conservation and environmental protection as the center of China's industrial economic development, in the direction of the sustainable development of China's industry, but also in the effective promotion of the sustainable development of China's inverter profession, so that I ...

Delixi bearing rust causes Delixi bearing rust causes

1. The instantaneous high temperature in the grinding process will make the surface of the workpiece reach a molten state, and the steel surface will react with the oxygen in the air chemically, which will form a very thin (20-30nm) iron oxide film.

Delixi molded case circuit breaker external two tripping wire connection Delixi molded case circuit breaker external two tripping wire connection

The molded case circuit breaker tripper is divided into undervoltage tripper and shunt tripper. This article explains the wiring method of the circuit breaker with sub-excitation tripper. The shunt tripper is often used as an additional accessory for the user, it is a remotely operated circuit breaker disconnection device, installed in the molded case circuit breaker, when the shunt ...

Delixi DZ47sGQF self-resettable over/undervoltage protector Delixi DZ47sGQF self-resettable over/undervoltage protector

In order to meet the needs of business development, Delixi Electric newly upgraded to create DZ47sGQF Navigator series of self-resettable over- and under-voltage protectors, the new products have a leading technology platform, better performance and quality, can completely replace the old product DZ47GQF. ...

Introduction of inverter energy feedback - Delixi Introduction of inverter energy feedback - Delixi

The essence of energy feedback is active inverter, and the energy feedback of the general inverter is completed by the reverse parallel three-phase inverter at the uncontrolled rectification of the pre-stage of the general inverter, and the regenerative energy is fed to the power grid. The main circuit of the energy feedback equipment is mainly composed of thyristors, IGBTs and IPM modules.

Delixi inverter selection points Delixi inverter selection points

Variable-frequency Drive (VFD) is an electric power control equipment that uses frequency conversion skills and microelectronics skills to control and communicate motors by changing the frequency of the working power supply of the motor. The inverter is mainly composed of rectifier (communication to DC), filtering, inverter (DC to ditch) ...

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

Delixi CDI-EM60 series inverter application Delixi CDI-EM60 series inverter application

Delixi CDI-EM60 series inverter is a high-performance communication motor drive, suitable for a variety of industrial use. This kind of inverter has a variety of advantages, such as ** rate, low harmonic distortion, low noise, low oscillation, etc. Delixi CDI-EM60 series inverter can be used in a variety of ...

Analysis of various models of Delixi circuit breaker Analysis of various models of Delixi circuit breaker

CDB1 miniature circuit breaker is a current-limiting high-breaking miniature circuit breaker with overload and short-circuit two-layer maintenance, which is suitable for communicating 50Hz, additional voltage 400V and below, and additional current 63A and below circuits.

Voltage regulator failure and solution - Delixi Voltage regulator failure and solution - Delixi

1. There is no output, no voltage indication or no start when the machine is turned on. Overvoltage or undervoltage maintenance 1. Adjust the internal output voltage adjustable potentiometer 2. The wrong phase and the lack of phase are maintained, and the two phases are arbitrarily replaced by three phases 3. The main control circuit board is broken 3. Replace 4. The output AC has been ...

Delixi inverter E102 series model Delixi inverter E102 series model

The S2 (single-phase 220V, 50/60HZ) comes standard with a built-in braking unit CDI-E102G0R4S2B 0.4KW CDI-E102G0R75S2B 0.75KW CDI-E102G1R5S2B 1.5KW CDI-E102G2R2S2B 2.2KW ...

The meaning of type B, type C, type D in circuit breaker - Delixi The meaning of type B, type C, type D in circuit breaker - Delixi

In the circuit breaker model, the requirement clearly indicates the type of tripper trip characteristic curve, which is a very important parameter in the circuit breaker model expression. The type of trip is generally indicated before the circuit breaker has additional housing current. For example...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top