Typical Cases | Leakage problem and treatment of lined magnetic flap level gauge in liquid chlorine tank level monitoring

Create Date: 2024-8-30 12:03:23|Source: Fuji Electric/Fujielectric

1. Application and development of magnetic flap level gauge in liquid chlorine tank level detection

Liquid chlorine is a high-risk and highly toxic substance, which is highly corrosive, and once it causes leakage, it will cause great harm to the environment and the human body, so it is particularly important to ensure the safe operation of the liquid chlorine tank. Accurate and reliable control of the liquid chlorine tank level is the key to ensuring the safety of the tank and preventing accidents.

As a practical liquid level instrument, the magnetic flap level gauge has the advantages of eye-catching indication, easy installation, good sealing, explosion-proof, corrosion-resistant, safe and reliable work, low failure rate, etc., and is widely used in chemical production, especially for the monitoring of liquid chlorine tank level.

In the early days, due to cost considerations, 304 stainless steel magnetic flap level gauge was mostly used for liquid chlorine tank level measurement, but due to the poor anti-corrosion performance of this magnetic flap level gauge, short service life, and easy to be corroded and cause leakage, there is a certain degree of safety hazard, and now it has almost been eliminated.

Then, for safety reasons, although the price is slightly higher than that of 304 stainless steel magnetic flap level gauge, many manufacturers began to choose 316L magnetic flap level gauge for liquid chlorine tank level measurement. Because 316L stainless steel contains molybdenum element, it improves the corrosion resistance to liquid chlorine, and its service life is longer than that of 304 stainless steel, but after a long period of use, it will still be slowly corroded, and eventually it is easy to cause failure and leakage, and it has gradually withdrawn from the relevant market.

In recent years, with the emergence of emerging materials and new processes, governments at all levels attach importance to environmental protection, manufacturers generally choose the inner lining type magnetic flap level gauge with better anti-corrosion effect, the main part of the magnetic flap level gauge is lined with a layer of corrosion-resistant plastic pipe in the stainless steel pipe, it isolates the liquid chlorine medium from the steel pipe, and the liquid chlorine medium is always contacted by the lining layer during the measurement process to achieve a better anti-corrosion effect.
Typical Cases | Leakage problem and treatment of lined magnetic flap level gauge in liquid chlorine tank level monitoring
2. Analysis and treatment of the causes of leakage of lined magnetic flap level gauge in liquid chlorine tank level detection

Although the anti-corrosion effect of the lined magnetic flap level gauge is good, in practical application, there are still many users similar to a chemical plant in Shandong who report that the lined anti-corrosion magnetic flap level gauge will also have leakage problems when running on the liquid chlorine tank, which has potential safety hazards and affects normal production.

So, what exactly causes the magnetic flap level gauge to leak?

Cause analysis

After dismantling, testing and analyzing the on-site magnetic flap level gauge, the automation technician confirmed that the lining material of the anti-corrosion magnetic flap level gauge was PTFE polytetrafluoroethylene plastic pipe. After the liner pipe was pulled out of the steel pipe, it was found that there were traces of liquid chlorine on the outer wall of the PTFE tube, but the tensile flanging and cone sealing parts of the PTFE pipe at both ends were intact.

The automation engineer preliminarily judged that the leakage of the magnetic flap level gauge was caused by the penetration of liquid chlorine liquid from the PTFE tube to the outer wall of the tube, and the direct cause was the improper selection of lining materials.

For the sake of rigor, the automation technicians consulted a lot of information for this purpose. The data further supports the correctness of the above judgment of automation.

According to the data, liquid chlorine liquid has a very strong permeability and cannot be used as a lining material for PTFE plastic pipes.

This is because PTFE fluorine material, that is, polytetrafluoroethylene, commonly known as "plastic king", although it is one of the best corrosion-resistant materials in the world today, suitable for strong acid, strong alkali, strong oxidant and other corrosive liquid media, but PTFE due to the large melt viscosity, does not have fluidity, can not use the production process of thermoplastic plastics in the molding process, generally use powdered PTFE resin by cold pressing to form a dense tube, after sintering and cooling to make a tubular product with a certain length.

Because it is cold-pressed forming, it is easy to form small gap defects between the internal molecules of the product, and some permeable media such as liquid chlorine can easily penetrate into the outer wall of the pipe under high pressure, resulting in leakage.

Problem handling

After research, in order to reasonably select the lined magnetic flap level gauge, solve the leakage problem when the lined magnetic flap level gauge measures liquid chlorine, improve the reliability of the lined magnetic flap level gauge, and ensure the safety of the operation of the liquid chlorine tank and the normal production of the liquid chlorine tank, the selection of the lined anti-corrosion magnetic flap level gauge must meet the following requirements:

1. Because liquid chlorine is a highly toxic substance and has strong corrosiveness to metal materials, the main material of the level gauge should be able to resist the corrosion of liquid chlorine for a long time, so it is necessary to choose materials with strong corrosion resistance as the inner lining, such as fluoroplastic materials.

2. Liquid chlorine is usually stored in a special liquid chlorine tank at a low temperature of -20 °C or a high pressure of 1.2MPa, so the level gauge must have a certain structural strength to meet the requirements of low temperature and high pressure.

3. The selected lining material should be able to prevent the leakage of liquid chlorine. This requirement is often ignored by the manufacturer of the magnetic flap level gauge, resulting in liquid chlorine leakage and production safety accidents.

After comparing the characteristics of different lining materials and production processes, combined with the experience of automation in the lining of magnetic level gauges, the R&D engineers finally confirmed that the selection of FEP polyperfluoroethylene propylene fluoroplastic pipes can completely solve the problem of liquid chlorine leakage.

This is because FEP polyperfluoroethylene propylene, also known as fluoroplastic, is a modified variety of polytetrafluoroethylene, and its corrosion resistance is comparable to PTFE, but its melt viscosity at 380 °C is lower than that of PTFE, which is 103-104Pa.S, and has good processing properties of thermoplastics. The pipe is formed by melting, extrusion and cooling of FEP granules, which is fundamentally different from the powder cold pressing of PTFE, which effectively overcomes the defect of easy leakage in the production and molding process of PTFE pipe.

Not only that, the R&D engineers found that the FEP type magnetic level gauge with the new fluorine material FEP instead of PTFE material for the lining pipe has a wider adaptability, and the FEP is lined with PTFE liner does not have some advantages:

First of all, the main float lined FEP anti-corrosion type magnetic flap level gauge is more suitable for a wider range of media than the PTFE-lined anti-corrosion type magnetic flap level gauge. The anti-corrosion characteristics of FEP and PTFE are comparable, but FEP has better fluidity than PTFE and can be formed by melt extrusion, which avoids the defect of poor permeability resistance of PTFE, so that it can resist the corrosion and penetration of highly permeable media such as liquid chlorine and bromine water, and is suitable for the measurement of more corrosive media.

Secondly, because the creep resistance and resilience of FEP are better than those of PTFE, the conical sealing surface of the FEP anti-corrosion magnetic flap level gauge lined with the bell mouth of the pontoon is also made of FEP material, which improves the reliability of the seal, reduces the probability of leakage, and prolongs the service life of the instrument.

According to the needs of liquid chlorine, bromine water and other molecules with strong permeability of the medium level measurement, a Flap-11Pb lined FEP magnetic flap level gauge was successfully developed, its anti-corrosion characteristics are equivalent to that of PTFE-lined magnetic flap level gauge, which can adapt to the measurement of most corrosive liquids, and can be used in the pressure range of 0-1.6MPa and the temperature in a wide range of -85-120 °C, which can be used for long-term monitoring of liquid chlorine tank level without leakage.

More on that
Production of 350 million units: An astonishing 4 figures for Fujifilm electromagnetic contactors Production of 350 million units: An astonishing 4 figures for Fujifilm electromagnetic contactors

In July 2022, Fuji Electric produced 350 million units of electromagnetic contactors. In fact, many years ago, the output of electromagnetic contactors has been maintained at about 50 million units in 8 years. 351 million electromagnetic contactors! What is this concept? If you import 350 million Fuji Electric ...

Fuji Electric and PetroChina jointly established Kunlun Fuji Instrument Company Fuji Electric and PetroChina jointly established Kunlun Fuji Instrument Company

On the morning of June 1, the opening ceremony of Wuxi Kunlun Fuji Instrument Co., Ltd. was held. Gong Peixing, chairman of the Wuxi CPPCC, was invited to attend the ceremony, and some responsible comrades of the new district participated in the event. In his speech, Chairman Gong said that the Wuxi Municipal Government and the New District Management Committee will continue to support...

The normal selection and capacity matching of the inverter is actually very important! The normal selection and capacity matching of the inverter is actually very important!

In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate. This will be covered in the following article 1. According to ...

Fuji Electric's Power Semiconductor Symposium officially kicked off Fuji Electric's Power Semiconductor Symposium officially kicked off

On March 16, 19, Fuji Electric Power Semiconductor Symposium was held in Guangzhou. More than 90 customers and agents from all over the country were invited. Fuji Electric looks forward to carrying out in-depth communication with you according to the publicity and education content of this seminar, so that everyone can have a good understanding of Fuji Electric.

23 projects signed at the China-Japan Energy Conservation and Environmental Protection Forum, Fuji Electric contributes "green energy" 23 projects signed at the China-Japan Energy Conservation and Environmental Protection Forum, Fuji Electric contributes "green energy"

From December 23 to 24, 2017, the 11th China-Japan Energy Conservation and Environmental Protection Comprehensive Forum, jointly organized by the National Development and Reform Commission and the Ministry of Commerce, the Ministry of Economy, Trade and Industry of Japan and the Japan-China Economic Association, was held in Tokyo. More than 800 government officials, experts, scholars, and entrepreneurs from China and Japan attended the event.

Fuji Electric - How to deal with inverter interference Fuji Electric - How to deal with inverter interference

In the field, the interference of the frequency converter is more frequent and more serious, and even causes the control system to be unable to be put into use. The operating principle of the inverter is destined to produce strong electromagnetic interference. The inverter includes a rectifier circuit and an inverter circuit, and the input alternating current passes through the rectifier circuit and the flat wave.

Launched the X-Series IGBT-IPM, which contributes to energy saving in production equipment with low-loss performance Launched the X-Series IGBT-IPM, which contributes to energy saving in production equipment with low-loss performance

Fuji Electric Corporation (Representative Director: Tsuhiro Kitazawa; Headquarters: Shinagawa-ku, Tokyo) is pleased to announce the launch of the X-Series IGBT-IPM*1, a power semiconductor product equipped with the latest seventh-generation X-Series chips that significantly reduce losses. 1. Background ...

How to use a hand-held ultrasonic flow meter How to use a hand-held ultrasonic flow meter

Handheld ultrasonic flowmeter is an essential tool instrument for flow detection. It is designed to improve the convenience of measuring the flow rate, with high measurement accuracy, large range ratio, no pressure loss, no moving parts, and small size, light weight, only need to install the sensor on the outer wall of the pipe.

5 types of inverter control - Fuji Electric 5 types of inverter control - Fuji Electric

The inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor, in which the control circuit completes the control of the main circuit, the rectifier circuit converts the AC power into direct current, and the DC intermediate circuit carries out the output of the rectifier circuit.

Fujifilm Inverter - How to Eliminate Inverter Electromagnetic Interference? Fujifilm Inverter - How to Eliminate Inverter Electromagnetic Interference?

The source of AC converter interference comes from interference from the external power grid. Harmonic interference in the power grid mainly interferes with the frequency converter through the power supply of the frequency converter. There are a large number of harmonic sources in the power grid, such as various rectifier equipment, AC and DC interchange equipment, electronic voltage adjustment equipment, nonlinear loads and lighting equipment.

"Epidemic prevention artifact" - non-contact infrared thermometer "Epidemic prevention artifact" - non-contact infrared thermometer

The pneumonia epidemic caused by the new coronavirus has affected the hearts of people across the country. In this "epidemic prevention war" of national mobilization, infrared thermometers (or infrared thermal imaging rapid screening equipment) are important tools in the hands of epidemic prevention personnel. In the A-share market, infrared thermometers ...

Can ultrasonic flowmeters be used in the production and processing of edible oil? Can ultrasonic flowmeters be used in the production and processing of edible oil?

Can a small flow ultrasonic flow meter be used for flow measurement of soybean oil? There are several steps in the processing of edible oil that require the use of flow meters to measure the volume and weight of how much oil flows out of the pipeline. Enterprises that produce and process edible oil need to be aware of the crude oil and ...

Fujifilm inverter – the 7th generation "X Series" industrial 1200V/2400A RC-IGBT module Fujifilm inverter – the 7th generation "X Series" industrial 1200V/2400A RC-IGBT module

In order to meet the market demand for miniaturization and high reliability of IGBT modules, Fuji Electric has developed RC-IGBTs (Reverse-Conducting IGBTs), which combine IGBTs and FWDs as single chips. The combination of the 7th generation "X series" chip technology and packaging technology with RC-IGBT technology makes the 7th generation ...

Inverter control cabinet application – Fuji Electric Inverter control cabinet application – Fuji Electric

Introduction to the main products and functions 1.1 Water supply frequency conversion cabinet (1) Ordinary water supply frequency conversion cabinet: this product can control a water pump motor frequency conversion water supply and a water pump motor power frequency water supply at the same time, and the power of the water pump motor is between 0.75KW and 5.5KW. The water supply capacity of the product can meet the needs of ...

9 nuclear energy innovation and excellence industry projects have been implemented in a centralized manner, and Fujifilm ultrasonic flowmeters with large-diameter applications have been selected 9 nuclear energy innovation and excellence industry projects have been implemented in a centralized manner, and Fujifilm ultrasonic flowmeters with large-diameter applications have been selected

On October 15, the "China Shandong Nuclear Energy (Equipment) Industry Development Promotion Conference" hosted by the Weihai Municipal Government, Shandong Provincial Power Bureau and the State Power Investment Group was held in Rongcheng City, Weihai, Shandong.

Inverter to DCS Interference Handling Solution - Fuji Electric Inverter to DCS Interference Handling Solution - Fuji Electric

The signal of the catalyst feed control valve of a company's DCS system (distributed control system) intermittently appears OOP (output signal line break) alarm, and the control valve is fully opened instantly, resulting in abnormal fluctuations in catalyst flow, which seriously affects the safe and stable operation of the device. Fault cause analysis and treatment ...

Introduction to the advantages and disadvantages of ultrasonic level gauges Introduction to the advantages and disadvantages of ultrasonic level gauges

Ultrasonic level gauge is a non-contact instrument that uses the principle of echo ranging. The echo ranging principle is also known as the travel time or travel time measurement principle. It emits energy waves through a device that can emit energy waves (generally pulse signals), and the energy waves are reflected when they encounter obstacles, and are reflected by a ...

What should I do if the body temperature measured by the forehead thermometer fluctuates? Listen to metrology experts answer top 10 questions about forehead thermometers What should I do if the body temperature measured by the forehead thermometer fluctuates? Listen to metrology experts answer top 10 questions about forehead thermometers

During the epidemic, citizens need to have their body temperature measured when they enter communities, companies, and shopping malls, and there are many questions about infrared forehead thermometers, ear thermometers and other appliances. The reporter interviewed experts from the Metrology Department of the Shanghai Municipal Market Supervision Bureau on the issues that the public was concerned about, and answered some questions about the forehead thermometer ...

Fuji Electric - How exactly does a frequency converter work? Fuji Electric - How exactly does a frequency converter work?

Since the advent of automatic induction motors, variable frequency operation has existed in the form of alternators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the generator speed ...

The industry and demand are integrated to accelerate the expansion of new areas The industry and demand are integrated to accelerate the expansion of new areas

With the proposal of "Made in China 2025" and the increasing role of science and technology in promoting new industries, the automation industry has begun to pick up, and the inverter market has regained its vitality and vitality after the downturn in the first two years. As a world-renowned provider of electrical automation products and systems, Fujifilm ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top