During the epidemic, citizens need to have their body temperature measured when they enter communities, companies, and shopping malls, and there are many questions about infrared forehead thermometers, ear thermometers and other appliances. The reporter interviewed experts from the Metrology Department of the Shanghai Municipal Market Supervision Bureau on issues of concern to the public, and answered some questions about the forehead thermometer.
Question 1: What kind of environment is required for forehead thermometer measurement?
A: The working environment of infrared forehead thermometer is generally between 16-35°C. If you work outdoors in a low temperature environment for a long time, the obtained values are prone to deviations. It is recommended to use it indoors in a windless environment. In addition, some infrared forehead thermometers have a physical temperature mode and a body temperature mode, and you should make sure that the infrared forehead thermometer is placed in body temperature mode.
Question 2: How can I get an accurate body temperature?
Answer: The infrared forehead thermometer measures the midpoint of the object from the center of the eyebrows to the hairline (also known as the center of the forehead). The measurement distance should meet the requirements of the manual, generally ranging from about 1-5 cm, to ensure that there is no cover from hair, sweat, hats, etc. When repeating the measurement, remove the infrared thermometer probe first and wait 5 seconds before taking the next measurement.
Question 3: Why does the body temperature sometimes go up and down?
A: The environment in which the person is tested can affect the reading. For example, turning on the heater in the car for a long time, being outdoors in a low temperature environment for a long time, and after strenuous exercise, it may cause the surface temperature of the forehead to be temporarily high or low.
Question 4: What should I do if my body temperature fluctuates?
A: It is recommended that the subject should wait for the body temperature to balance before taking the measurement. For example, turn off the heating in the car when you are almost at the temperature measurement point, or get out of the car to measure at the temperature measurement point. After strenuous exercise, you should rest and adjust for a few minutes before taking the measurement.
Question 5: Is there any other way to measure the forehead temperature?
Answer: When using a handheld infrared thermometer, in principle, it should be operated in strict accordance with the instructions to ensure the accuracy of the value; It is normal to take measurements on different parts of the body and have a slight deviation in the results; In winter and spring, due to the low temperatures, it is advisable to measure the parts wrapped in clothing or scarves, such as the wrists or neck, when measuring people entering the room from outside or when using a thermometer outdoors, so that the measurement can be closer to reality.
Question 6: Many places do not have indoor temperature measurement conditions, what should I do if I measure outdoors at low temperatures?
A: There are two ways to do this. Method 1: First measure a reference temperature from a non-febrile person (such as yourself or a colleague), use it as a benchmark, and immediately take a second measurement once it is significantly higher than the benchmark temperature. Method 2: Stick the warm baby on the outside of the thermometer to help maintain the normal working temperature.
Question 7: At present, it is difficult to buy forehead thermometers, can industrial infrared thermometers be used to measure human body temperature?
Answer: Generally, the measurement range of industrial infrared thermometer is 30°C-1000°C, and the measurement accuracy in the human body temperature range is generally greater than ±1.0°C, which is not suitable for human body temperature measurement.
Question 8: How long does the forehead thermometer need to be calibrated?
Answer: The use environment and use of each forehead thermometer are different, and there is no unified regulation for such measuring instruments that are currently not compulsory verification, and users can decide independently according to the frequency of use and usage. If the frequency of use is high, the calibration interval can be shortened accordingly.
Question 9: Do I need to calibrate my newly purchased forehead thermometer?
Answer: Generally speaking, although the new forehead thermometer has been inspected and tested by the factory, considering that some companies are batch by batch inspection, as well as product transportation factors, it is recommended to calibrate before use to ensure that the value of the forehead thermometer is accurate and reliable.
Question 10: If there is a real demand, how to send it for inspection?
Answer: At present, metrology departments across the country are fully engaged in the front line of epidemic prevention and control to ensure that the infrared body temperature measurement value is accurate and reliable. Local metrology departments have opened a green channel for epidemic prevention and control temperature measurement equipment services, and local metrology institutes can be contacted if there is a testing need. Shanghai Institute of Metrology and Testing Technology is carrying out free testing of forehead thermometers, ear thermometers, and medical electronic thermometers used in public places, but due to the current demand for testing, it is recommended that communities, shopping malls, office buildings, and parks be collectively sent for testing.
|
More on that
|
Fuji Electric serves the public to create a safe, energy-saving and operable medium frequency induction furnace
As we all know, the foundry industry is the foundation of the development trend of China's processing and manufacturing industry, and the technical development trend of the foundry industry and its level have limited the development trend of the processing and manufacturing industry. Fuji Electric uses the skills it has cultivated over many years to make use of its excellent IGBT technology and electrical ...
|
|
China's instrumentation industry has entered a new period of development.
Despite the global economic downturn, the development of the instrumentation industry has maintained a steady upward trend, and the growth rate has not slowed down. In fact, whether it is a foreign-funded instrumentation enterprise that has begun to use mergers and acquisitions, commissioned production and other investment max3232EUE+T ...
|
|
5 types of inverter control - Fuji Electric
The inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor, in which the control circuit completes the control of the main circuit, the rectifier circuit converts the AC power into direct current, and the DC intermediate circuit carries out the output of the rectifier circuit.
|
|
How is data protection carried out? - Fuji Electric inverter
Set F00 to 1 for data protection, which requires the STOP button + RISE button to operate.
|
|
The debugging method for putting the inverter into operation - Fuji Electric
It is usually completed in accordance with the three steps of no-load trial operation of the inverter, no-load operation of the inverter with motor and commissioning operation with load, and the following three steps are introduced in detail.
1**No-load test operation of line inverter
**No-load test run of the inverter First check that all wiring of the inverter is ...
|
|
Fuji Electric and PetroChina jointly established Kunlun Fuji Instrument Company
On the morning of June 1, the opening ceremony of Wuxi Kunlun Fuji Instrument Co., Ltd. was held. Gong Peixing, chairman of the Wuxi CPPCC, was invited to attend the ceremony, and some responsible comrades of the new district participated in the event.
In his speech, Chairman Gong said that the Wuxi Municipal Government and the New District Management Committee will continue to support...
|
|
What are the self-protection functions of Fuji Electric - inverter?
After years of development, the inverter (VFD) has begun to transition from a purely industrial product to a civilian field. The use of VFD can be said to have gone to the countryside, (constant pressure water supply) penetrated into thousands of households (inverter air conditioning). But after using it for a while, you will find that the failure rate of VFD is much higher than that of the average household ...
|
|
Fuji Electric ships ship exhaust gas cleaning system in the first shipment
2018-10-22
Fuji Electric Pillar Co., Ltd., headquartered in Tokyo, Japan, President Michihiro Kitazawa announced today that it is shipping its first ship exhaust gas cleaning system (EGCS) through its Chiba plant.
1. Background
In order to reduce the air pollutant sulfur oxides (SOx) ...
|
|
Fuji Electric – How do you determine the breaking capacity of a circuit breaker?
(1) Is there a difference between ICU and ICS in the sample?
(2) What is breaking capacity? How do I choose a breaking capacity?
(3) Why must the circuit breaker use 0.8-0.9 times the rated current value?
(4) How to determine the sensitivity current value?
(5) The insulation space of the circuit breaker must exist ...
|
|
Fuji Electric Corporation has set sustainability goals with the aim of contributing to the realization of a sustainable society and the 2050 Environmental Vision
Fuji Electric Corporation (hereinafter referred to as "FE"), headquartered in Tokyo, Japan, under the leadership of President Mitsuhiro Kitazawa, is pleased to announce that it has established development goals*1 aimed at achieving a sustainable society, as well as a new policy called Environmental Vision 2050.
*1: Sustainability Goals...
|
|
Fuji Electric plans to increase its production capacity of next-generation power semiconductors by 10 times by 2024
Fuji Electric will increase its production capacity of next-generation power semiconductors by approximately 10 times in FY2024 compared to FY2020. By 2025, it will increase the sales of silicon carbide power semiconductors to about 10% of its semiconductor business, and the goal is to achieve half of the global silicon carbide power supply by 2026.
|
|
Fuji Electric exhibited at PCIM Asia
On June 28, 2016, the three-day Shanghai International Power Components and Renewable Energy Management Exhibition (PCIM Asia) was grandly opened at the Shanghai World Expo Exhibition & Convention Center. Focusing on renewable energy technology, Fuji Electric (China) Co., Ltd. brought new products "Four Beauties" to the exhibition, which were Fuji ...
|
|
Accumulation of experience in testing skills in inverter maintenance
1. Detection of fixed resistors.
A. Connect the two pen pens (regardless of positive and negative) with the pins at both ends of the resistor to measure the actual resistance value. In order to improve the measurement accuracy, the range should be selected according to the magnitude of the nominal value of the resistance to be measured. Due to the nonlinear relationship of the ohmic scale, its ...
|
|
Fuji Electric - How to choose a high-power inverter model
In order to achieve a more efficient and controllable operation of the motor, and avoid the waste of power of the motor drive system, the inverter came into being. However, due to the variety of motor load types, the functional requirements for the equipped inverter are also different, so how to choose the right transformer for the motor...
|
|
Did you really choose the right circuit breaker?
How to choose a circuit breaker?
In fact, there are not a few people who do not know the steps of circuit breaker selection, Fuji Electric's suggestion is that you can roughly choose the model of circuit breaker by following the following 7 steps.
When the load is a motor, why must it be protected with a circuit breaker + solenoid switch?
That...
|
|
Fujifilm inverter - the application of inverter energy-saving technology in coal mines
As we all know, coal enterprises are large consumers of electricity, and their electricity consumption costs account for a considerable proportion of their production costs. In coal mining enterprises, due to the fact that the production equipment generally meets the characteristics of long service life, the phenomenon of large horse-drawn trolleys caused by large model selection, serious waste of electric energy, and the operation efficiency of equipment is often ...
|
|
How to choose between ultrasonic flowmeter and electromagnetic flowmeter?
As the two most important forms of flow meter in the current flow measurement field, how to choose? Xiaobian elaborates on the characteristics of the following two from the following aspects, hoping to provide some suggestions on selection.
1. Ultrasonic flowmeter
Measuring principle of ultrasonic flow meter:
...
|
|
Fuji Electric – How to improve the operating temperature of the inverter
After the inverter runs uninterrupted for a long time, the high temperature generated inside has serious hidden dangers to the operation of the inverter, especially in summer. The ultimate operating temperature of the inverter inside the inverter is generally 125 °C, and the temperature of the inverter inverter module and IGBT can sometimes reach 110 °C.
|
|
Fujifilm Inverter - How to Eliminate Inverter Electromagnetic Interference?
The source of AC converter interference comes from interference from the external power grid.
Harmonic interference in the power grid mainly interferes with the frequency converter through the power supply of the frequency converter. There are a large number of harmonic sources in the power grid, such as various rectifier equipment, AC and DC interchange equipment, electronic voltage adjustment equipment, nonlinear loads and lighting equipment.
|
|
Fuji Electric - How exactly does a frequency converter work?
Since the advent of automatic induction motors, variable frequency operation has existed in the form of alternators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the generator speed ...
|
|