The low-voltage air circuit breaker is the primary equipment for low-voltage power distribution, and it should be able to operate reliably when the electrical equipment is no-load, load-loaded or short-circuited. Its primary function is to maintain the circuit and equipment, can turn on, carry and break the current under normal circuit conditions, and can also turn on and carry the current at a certain time and break the current under the specified abnormal conditions (such as short circuit conditions).

Low-voltage air circuit breaker, also known as structural circuit breaker, has a structural current range of 630-6300A, and is mainly used for incoming wires, bus connections and other high-current circuits of low-voltage power distribution. In practical applications, the circuit breaker trips by mistake, which refers to the active tripping of the circuit breaker when there is no short circuit and no abnormality of the line.

                                  Analysis of the reasons why the maintenance of Delixi frame air switch can not be closed

1) The power supply disappears, such as the closing fuse, the control fuse is blown or defective.

2) The small switch of the closing power supply in the local control box is not closed

3) The circuit breaker is closed and locked, and it is not restored

4) The circuit breaker operates the "remote-local" selection switch in the control box in the local position

5) The control circuit is disconnected

6) The synchronization loop is disconnected

7) The closing coil and the closing circuit relay are burned out

8) Operation relay failure

9) The control handle is out of order

10) Poor contact of the control switch

11) Poor auxiliary contact of circuit breaker

12) Operational organization failure

13) The DC voltage is too low

14) Poor DC contact

Taking the zero-crossing arc extinguishing of SN10-10 I type I oil-less circuit breaker as an example, in a type experiment. When the 10% and 30% combined experiments are performed, the phenomenon of zero-crossing arc extinguishing is presented. Judging from the waveform. There is no abnormal situation, only after the zero point is crossed, the arc is cut off, and after disintegration. It is found that the arc extinguisher of the circuit breaker is loose and not compressed, forming an arc extinguishing chamber to relieve pressure and make the arc extinguishing pressure small, and blow the arc continuously. After analysis, the reason is that the organization and transmission part are accurate and reliable. It is to rely on mechanical force to break the arc when the conductive rod is going down.
More on that
Delixi built-in bypass soft starter CDRA-K3 series features Delixi built-in bypass soft starter CDRA-K3 series features

1. A variety of starting methods Current limiting soft start, voltage ramp soft start, ramp plus current limiting soft start. 2. High reliability Signals in the control system are digitized by high-performance microprocessors. ...

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

The impact of inverter cable design on the life of the motor and cable - Delixi The impact of inverter cable design on the life of the motor and cable - Delixi

Reflected waves caused by a cable-motor impedance mismatch are prevalent in all AC VFD uses. The severity of the problem depends on the length of the cable, the rise time of the PWM (Pulse Width Modulation) carrier, the voltage of the VFD, and the magnitude of the impedance difference between the motor and the cable. ...

Delixi three-phase transformer introduction Delixi three-phase transformer introduction

All large AC power blocks are transmitted and distributed at high voltage levels via a three-phase transformer. Single-phase transformers can be electrically connected to form a three-phase transformer bank in a distribution system. But the standard is to combine a single phase coil into a three-phase transformer unit on a common core ...

The difference between the poles of Delixi circuit breaker The difference between the poles of Delixi circuit breaker

Circuit breakers account for a very large proportion of electrical sales and have a wide range of applications, but there are different standards for circuit breakers. For example, 1P, 1P+N, 2P, etc., there are also differences between them. 1. 1P circuit breaker, it is a single-stage ...

Delixi rangefinder analysis Delixi rangefinder analysis

Delixi Group focuses on low-voltage power distribution and industrial automation in the field of comprehensive solutions suppliers, founded in 1984, is a collection of industrial operations, brand operations, capital operations as one of the large enterprise groups, for 18 consecutive years ranked among the top 500 Chinese enterprises. Delixi rangefinder is designed for ...

Delixi CDI-EM60 inverter technical characteristics Delixi CDI-EM60 inverter technical characteristics

Delixi CDI-EM60 inverter has optimized open-loop vector control, V/F control, stable function, optimized function, standard configuration of common users, but also expand multi-channel I/O interface and communication function, is a delicate type of small power type. ...

Delixi voltage regulator safety installation method Delixi voltage regulator safety installation method

In people's lives, voltage regulators are not short, but some people do not install voltage regulators correctly, which leads to great safety hazards in the use of voltage regulators. Here's how to properly install the regulator: ...

Daily maintenance of reducer - Delixi Daily maintenance of reducer - Delixi

The reducer is a kind of transmission equipment used for low speed and high torque, which uses the speed converter of the gear to reduce the number of revolutions of the motor (motor) to the required number of revolutions, and obtains a large torque organization. Its main function is to reduce the speed and improve the output torque at the same time, and the torque output share is according to the motor ...

Analysis of various models of Delixi circuit breaker Analysis of various models of Delixi circuit breaker

CDB1 miniature circuit breaker is a current-limiting high-breaking miniature circuit breaker with overload and short-circuit two-layer maintenance, which is suitable for communicating 50Hz, additional voltage 400V and below, and additional current 63A and below circuits.

Delixi switching regulator basics Delixi switching regulator basics

1. What is a switching regulator? Switching voltage regulators, some people call it regulators, voltage regulator sources. Complete voltage regulation, is the demand control system (negative feedback), from the automatic control theory we know that when the voltage rises, it will be lowered through negative feedback, and when the voltage drops, it will be ...

Precautions for the use of Delixi three-phase AC voltage regulator Precautions for the use of Delixi three-phase AC voltage regulator

There are many types of three-phase communication regulators in Delixi, the most commonly used ones are SJW and SBW, etc., so we need to pay attention to the process of application: First of all, it must be operated correctly according to the instructions of the voltage regulator.

The difference between air switch and leakage protection switch - Delixi The difference between air switch and leakage protection switch - Delixi

(1) The function is different. An air switch is a kind of circuit breaker that maintains "something", which can maintain the safety of the entire household wiring and appliances, and avoid the overheating and burning of the wires. The leakage maintenance switch is a kind of circuit breaker for maintenance personnel, which can block the circuit in time when leakage is carried out to avoid the danger of electric shock.

Introduction of four-quadrant regulator - Delixi Introduction of four-quadrant regulator - Delixi

A four-quadrant power supply is a power supply capable of absorbing and supplying positive and negative currents and voltages. While a simple voltage converter is capable of generating a fixed output voltage from the input voltage, this feature is not sufficient in some applications. An example is the control of voltage nodes connected to capacitors that ...

Introduction of molded case circuit breaker - Delixi Introduction of molded case circuit breaker - Delixi

Delixi plastic case circuit breaker is also called equipment circuit breaker, the external contact of the grounding terminal, arc extinguisher, tripper and operating organization are installed in a plastic shell. Auxiliary contacts, undervoltage trippers, parallel trippers, etc. Most of them are modular, very compact in structure, and generally do not consider maintenance ...

Delixi won the lawsuit "Delixi United" to defend its rights by legal means Delixi won the lawsuit "Delixi United" to defend its rights by legal means

  On July 14, the official Weibo of the Beijing Municipal Patent People's Court "Intellectual Property Beijing" released information that Delixi Group Co., Ltd. (hereinafter referred to as "Delixi Group") sued the former administrative department of China's State Administration for Industry and Commerce to dispute the proposal has been adjudicated in the first instance not long ago, and the appellant Delixi ...

Delixi inverter load type and selection points Delixi inverter load type and selection points

The correct selection of the inverter is very important for the normal operation of the control system. When selecting an inverter, it is necessary to have a thorough understanding of the load characteristics driven by the inverter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan and pump load. ...

Delixi inverter E180 series technical features Delixi inverter E180 series technical features

1. Superior performance The new vector control algorithm is adopted, and the starting cabinet is large, the torque response is fast, and the control accuracy is high, which further improves the operation efficiency of the motor. 2. Powerful function and low cost of use Built-in large number of ...

Low dropout linear regulator application type - Delixi Low dropout linear regulator application type - Delixi

1.AC/DC the use of power supply Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the AC voltage is stepped down by the power transformer to obtain the low voltage of communication, and then the unstable DC voltage is obtained through the rectifier filter circuit, and then the voltage is regulated linearly by the low dropout ...

Delixi relays and precautions Delixi relays and precautions

Quickness: It means that the maintenance device should be able to remove the short circuit as soon as possible, and its intention is to improve the stability of the system, reduce the damage to the peak equipment and lines, reduce the scope of the process, and improve the effect of active overlapping room and standby power supply or standby equipment active investment. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top