1. The use environment of regulated power supply requires good ventilation, no moisture, no corrosive gas, explosive substances, conductive dust Egypt steam, etc., and it is required to be installed in places without intense oscillation.
2. The voltage regulator should reasonably select the specifications of the regulated power supply according to the power of the electrical equipment, the inrush current and other conditions, and leave enough power margin, and this series of power supplies should not be used for impact loads.
3. Regularly remove the dust inside the regulator to ensure that the gears and coils are clean. If the long-term continuous operation, the wear of the carbon brush should be checked regularly, and the contact force between the carbon brush and the coil should be adjusted if necessary, so that the contact force between the carbon brush and the coil is good, so as to prevent flashover, if the carbon brush is severely worn, it should be replaced in time.
4. Do not cover the power supply with a dust cover such as a plastic cover, otherwise it will hinder the heat dissipation of the regulated power supply and cause the regulated power supply to overheat.
5. Please do not use gasoline, rosin perfume and other solvents to scrub the stabilized power supply to avoid corrosion of the stabilized power supply paint film and plastic parts.
6. The ground wire and the neutral wire of the voltage regulator shall not be connected in reverse or together, otherwise the body of the stabilized power supply may be energized or cannot operate normally.
7. The phase line and the neutral line of the voltage regulator shall not be reversed, and the filtering effect of the stabilized power supply will be severely affected when the single-camera type is reversed, and the three-camera type will form a severe short circuit when it is reversed, and the phase stabilized power supply will be severely damaged.
8. The input and output circuits of the three-phase regulator model must be connected in strict accordance with the three-phase four-wire system, and the zero line shall not be omitted, otherwise the stabilized power supply and electrical equipment may be damaged.
9. The output plug-in socket of the single-phase high-power regulated power supply can only withstand a maximum current of 10A, and the user should connect the larger power load to the terminal of the voltage regulator.
|
More on that
|
Delixi relay maintenance method
Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.
|
|
How to select Delixi voltage regulator
1. For pure resistive loads such as incandescent lamps, resistance wires, electric furnaces and other equipment, the power of the voltage regulator should be 1.5 times the power of the load equipment - 2 times that of the load equipment, for example, if your electric furnace is about 250W, you can choose a voltage regulator with a power of 500W.
2. Rationality ...
|
|
Delixi voltage regulator safety precautions
1. When the stabilized power supply is powered on, please do not disassemble the stabilized power supply or pull the input and output cables of the stabilized power supply at will to prevent electric shock or other electrical safety accidents.
2. The input and output connections of the regulated power supply must be reasonably arranged, ...
|
|
Delixi meter is too fast or too slow causes and solutions
Common fault phenomenon: the meter is fast or slow. The error is positive (negative) and does not meet the requirements
Causes:
1. The product has had severe impact and vibration during transfer, installation and transportation;
2. The ambient temperature, preheating and testing time of the product ...
|
|
Delixi occasion to choose the inverter
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, the output of the inverter should be fully considered ...
|
|
Linear regulator and switching regulator concept - Delixi
01. What is a linear voltage regulator?
A linear regulator uses a transistor or FET that operates in its linear region to subtract the excess voltage from the input voltage applied to generate a conditioned output voltage.
The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...
|
|
Precautions for the use of Delixi three-phase AC voltage regulator
There are many types of three-phase communication regulators in Delixi, the most commonly used ones are SJW and SBW, etc., so we need to pay attention to the process of application:
First of all, it must be operated correctly according to the instructions of the voltage regulator.
|
|
The general principle of circuit breaker selection - Delixi
(1) The additional operating voltage of the circuit breaker ≥ the additional voltage of the line.
(2) The additional current of the circuit breaker ≥ the line load current.
(3) The additional short-circuit of the circuit breaker can be turned on and off to ≥ the maximum shortness that may be present in the line.
|
|
How about Delixi switch?
Delixi focuses on the development of green energy-saving industry, the construction of LED ecological industrial chain. It has established an industrial development format with Shanghai as the research and development center and Hangzhou and Jiaxing as the production base of LED lighting products, specializing in the development, production and sales of LED fluorescent lamps, three-proof lamps, downlights, spotlights, street lamps and other high-tech products.
|
|
Changes in the control mode of the inverter - Delixi inverter
In the process of practical speed regulation, an ordinary AC power supply with adjustable frequency can not meet the requirements of speed regulation and control of asynchronous motors, and must also take into account the effective use of the motor magnetic field, the pressing starting current and the desired torque characteristics, such as low-frequency torque characteristics.
|
|
Delixi time control switch adjustment
Press the revoke function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time when the demand is closed and open to the specified value, if the demand is set to multiple groups, then press the punctual function key to set, without multiple groups ...
|
|
How to wire and use the number of switches when the inverter starts and stops - Delixi
The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...
|
|
Delixi AC contactor fault causes and solutions
First, the iron core may not be able to suction power
Causes: The power supply voltage is too low or fluctuates too much, the power supply capacity of the operating circuit is lacking or the wire is broken and the control contact is poor, the technical parameters of the coil are inconsistent with the application conditions, and the product itself is damaged.
Solution: Turn up the power ...
|
|
Delixi Electric rushed to the front line of the anti-epidemic in various places
On March 12, Delixi Electric partner Qingdao Hengtong Ruide received an order, continued to deploy a batch of components to be shipped to Laixi cabin hospital, Delixi Electric strategic cooperation plant Qingdao Fengtai Electric overnight deployment, 24 hours smoothly completed handover, escort for Qingdao war epidemic.
...
|
|
Delixi circuit breaker P number selection points
As far as miniature circuit breakers are concerned, 1P+N, 1P, and 2P are generally used as the on-off control of single-phase electrical appliances, but the functions are different. In order to facilitate the user's selection and difference, the difference of the P number of circuit breakers and the selection method are briefly analyzed.
...
|
|
The difference between circuit breaker and disconnector - Delixi
The disconnector is a kind of switching equipment that is mainly used for "blocking the power supply, reversing the operation, and connecting and blocking the small current circuit", without arc extinguishing function. When the barrier switch is divided into directions, there is an insulation distance between the contacts that meets the specified requirements and a significant disconnection mark; When in the azimuth, it can carry ...
|
|
Classification of low-voltage electrical appliances - Delixi
1. Classified according to the operating voltage level
Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation.
High-voltage electrical appliances: communication 1200V or more, DC 1500V or more.
...
|
|
Delixi inverter EM60 series model introduction
S1 (Single-phase 110V, 50/60HZ)
CDI-EM60G0R75S1 0.75KW
CDI-EM60G1R5S1 1.5KW
S2 (Single Phase 220V, 50/60HZ)
CDI-EM60G0R4S2 (without built-in brake unit) 0.4KW
CDI-EM60G0R4S2B (Built-in ...
|
|
Delixi voltage regulator fault performance and elimination
Regulator problem 1: The regulator cannot be started
Reason: Whether the phase sequence of the input power cord has been changed, and the air switch in the machine is not turned on or broken.
Repair methods: 1. Swap the two power supply wires arbitrarily or check whether the power supply line is correct; 2. Close or replace the switch.
Voltage Regulator ...
|
|
Delixi selection of wire points
When buying wires, the first thing to look at is two aspects: conductors and insulation.
1. Conductors
1. Color
High-quality copper is called "red copper" or "red copper" - the color of this copper is red, purple, and purple-red.
The worse the copper ...
|
|