1. The problem current reaches or exceeds the set operating current value.
2. The problem current continues to arrive at the set time of action.
Therefore, it is necessary to ensure that the Delixi circuit breaker will not trip beyond its liquid level. The current setpoint and the time setpoint must match the outstanding. If the overcurrent maintenance setting value of the primary circuit breaker is 700A and the continuation time is set to 0.6 seconds, then the filter maintenance setting value of the secondary circuit breaker should be decreasing according to a certain share, such as setting the current to 630A and setting the time to 0.3 seconds. In this case, if there is a problem in the maintenance of the secondary circuit breaker, regardless of whether the faulty current reaches the stator of the primary circuit breaker, when the faulty current continues to 0.3 seconds, it will be cut off by the secondary circuit breaker and will not reach 0.6 seconds of the primary circuit breaker.
Whether it's a short circuit problem or a grounding problem, the type of maintenance is the same. It is possible to meet the maintenance setting value of the multi-stage circuit breaker at the same time. When the maintenance value of the circuit breaker is set, the time is also set. So, is it possible to make sure it doesn't skip the ranks? Not necessarily because from the point of view of the set value, the moment required for the circuit breaker to completely disconnect the faulty current is not only the moment of fundamental judgment, but also the moment of action of the machine itself, which varies with the performance of different data and equipment.
|
More on that
|
Delixi control transformer structure type
Delixi's control transformer is one of the products used in many equipment, the type of Delixi transformer is divided into: BK, JBK, BKC, JMB, BJZ, DG, BZ and other series of control lighting transformers, with excellent performance, reliable work, wide applicability and other characteristics, generally used in machine tools, mechanical ...
|
|
Delixi solid state relay relative to AC contactor characteristics
Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose?
1. First of all, the solid ...
|
|
Delixi occasion to choose the inverter
We need to ensure that the capacity of the inverter is matched. First of all, according to the nature of the load, the correct selection of the type of inverter.
When selecting the inverter, the current value of the actual motor should be used as the basis for the selection of the inverter, and the rated power of the motor can only be used as a reference. Secondly, the output of the inverter should be fully considered ...
|
|
Precautions for the use of Delixi leakage protector
1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the working current balance in the zero sequence current transformer and causes the leakage protector to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.
|
|
Delixi inverter constant pressure variable frequency water supply system control problem
1. The pressure of Delixi inverter system is unstable and easy to vibrate?
Answer: The pressure of the system is unstable, which may be due to the following reasons:
A. There is a problem with the direction of the pressure of the pressure sensor acquisition system, and the pressure collection point is too close to the water outlet of the water pump, and the pressure of the pipeline is affected by the water outlet ...
|
|
Delixi Electric universal switching power supply
Delixi general switching power supply can provide stable DC output products, widely used in communications, LED displays, industrial control, radio and television, computer networks, medical equipment, intelligent monitoring and other fields.
Delixi universal switching power supply SA, DA, TA, QA Type 85 - 132 / ...
|
|
How to wire and use the number of switches when the inverter starts and stops - Delixi
The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...
|
|
The circuit breaker is set in accordance with the principle - Delixi circuit breaker
1. When the main circuit is equipped with a total leakage maintainer, the main barrier switch, the branch barrier switch, the main circuit breaker, the branch circuit breaker or the main fuse, and the shunt fuse should also be installed. When the total leakage maintainer is a leakage circuit breaker with short-circuit, overload, and leakage maintenance functions, it can not be ...
|
|
The 2016 Delixi Electric Construction Industry Summit was successfully held
2016 is the first year of the "13th Five-Year Plan", with the adjustment of China's economic structure, the construction profession is also changing. On September 8th, with the theme of "riding the wind and waves, building the future together", the Delixi Electric Construction Career Summit opened in Qingdao, the "International Sailing Capital". The summit ...
|
|
Delixi E180 universal inverter introduction
Product Introduction
With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...
|
|
Problems affecting the normal operation of the inverter - Delixi
Seriously affect the normal operation of the inverter. The core components of the inverter are IGBT power semiconductor switching components. When they are working properly, they generate a lot of heat. If there is no fan forced cooling, the sensing head will immediately detect (IGBT) overheating (IGBT) and send it ...
|
|
Delixi circuit breaker insulation accident
The circuit breaker insulation incident can be divided into the internal insulation terminal and the external insulation incident. The hazards caused by internal insulation incidents are generally greater than those of external insulation.
(1) Internal insulation incidents
The internal insulation end is mainly a bushing and a current transformer ...
|
|
LDO low dropout linear regulator features - Delixi
Since it is used as a low dropout voltage regulator, the first feature is the extremely low input and output voltage difference, and secondly, it also has stable voltage output, low noise, small ripple, small size, and simple peripheral circuits. If an LDO regulator is used when planning the circuit, the general requirement is at least ...
|
|
Low dropout linear regulator application type - Delixi
1.AC/DC the use of power supply
Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the AC voltage is stepped down by the power transformer to obtain the low voltage of communication, and then the unstable DC voltage is obtained through the rectifier filter circuit, and then the voltage is regulated linearly by the low dropout ...
|
|
Delixi product installation, operation and maintenance instructions
Normal conditions of operation, installation, and transportation
1 Normal operating conditions
Appliances that meet the rules of this code should be able to operate under the following conditions.
Note: See Appendix B for the requirements of non-standard application conditions.
Non-standard ...
|
|
The difference between Delixi single-phase and three-phase AC voltage regulators
Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on.
...
|
|
Delixi small contactor structure introduction
Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking.
...
|
|
Delixi circuit breaker left zero right fire meaning
The so-called "left zero and right fire of the circuit breaker" is nothing more than the order of the sockets - when facing the socket, the socket on the left is the neutral line, the socket on the right is the front, and that's it.
Delixi socket wiring may not be "left zero right fire". ...
|
|
The difference between the poles of Delixi circuit breaker
Circuit breakers account for a very large proportion of electrical sales and have a wide range of applications, but there are different standards for circuit breakers. For example, 1P, 1P+N, 2P, etc., there are also differences between them.
1. 1P circuit breaker, it is a single-stage ...
|
|
Analysis of common problems of inverter - Delixi
1. Why does the maintenance function of the inverter operate when the clutch is connected to the load?