32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 1.5
Power supply: DC24V±20%
Digital inputs: 8
This article introduces CHINT/CHINT NSC1 Series Motion Controller NSC1-P2 products if you are interested, please also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-125
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Terminal Block-SAK Series
SAK series is suitable for AC 50Hz or 60Hz, rated voltage to 800V, rated cross-sectional area of 2.5-70mm2 in power and control circuits, as wire connection. It is installed on TH35 rails.
Comply with standards: GB/T 14048.7, IEC 60947-7-1.
This article introduces CHINT ...
|
|
CHINT/CHINT UVT-7 undervoltage tripper
The UVT-7 undervoltage tripper is mainly used for under-voltage protection in the line with AC 50Hz (60Hz) and rated working voltage of 230V.
Main parameters and technical performance
Rated operating voltage: 230V AC
life span
Mechanical life: ≤4000 times
This article introduces ...
|
|
CHINT/CHINT OUVT-X1H over/undervoltage tripper
OUVT-X1H over-voltage and under-voltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-63, NBH-40 series circuit breaker matching, when the terminal voltage of the tripper is reduced to the undervoltage protection range or increased to the overvoltage protection range, the tripper acts and drives the circuit breaker to automatically ...
|
|
CHINT/CHINT NB1LE-63□ residual current operated circuit breaker
NB1LE-63□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage unipolar two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V, rated current up to 63A. When a person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can ...
|
|
CHINT/CHINT NTP1 series industrial touch screen
1.1 System Features:
Based on the Linux system, the system is stable, efficient and reliable. Industrial-grade high-performance Cortex A8 processor with a clock speed of 600MHz. The COM port integrates RS232/422/485 communication mode. The product provides USB master station and USB slave port, and the USB slave download port supports 10 ...
|
|
CHINT/CHINT CJX1-K Series Contactors The operating frequency is 1200 hours
Introduction: CJX1-K series AC vacuum contactor (hereinafter referred to as contactor), mainly used for AC 50Hz-60Hz, rated insulation voltage of 1000V, rated working voltage of 380V under the AC-3 use category of rated working current to 820A in the circuit, for long-distance connection and disconnection ...
|
|
CHINT/CHINT NVF5-GS series inverter has a maximum power of 45KW
Introduction: NVF5-GS series water supply inverter is a small size, cost-effective water supply inverter tailored by CHINT for the water supply industry. The product supports fixed inverter mode, cyclic inverter mode, soft stop and emergency stop function, overpressure protection function, sleep function, rest ...
|
|
CHINT/CHINT AL-X1H alarm contact
AL-X1H alarm contact is mainly used in the line with AC rated voltage to 415V or DC rated voltage to 130V, and is assembled with NBH-40 and NBH-63 series circuit breakers for signal indication of remote circuit breaker fault breaking.
The alarm contact is an accessory product that is assembled on the left side of the circuit breaker for use.
|
|
CHINT NB3LE-63M residual current action circuit breaker
This product is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances.
Conform to the standard: GB/T 16917.1 IEC 61009-1, obtained CCC certification...
|
|
CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/10
NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...
|
|
CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5000
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT Terminal Appliance —NUH-40B Surge Protector
NUH-40B is a surge protector with short-circuit protection function, suitable for AC 50Hz, rated voltage 230V/400V circuits and equipment, meet SPD Class II test, can protect equipment from lightning strikes or other transient overvoltage, the product has short-circuit protection function, can be used in the protector...
|
|
CHINT/CHINT NL1E-63 residual current action circuit breaker
NL1E-63 residual current action circuit breaker (without overcurrent protection) is suitable for AC 50Hz, rated voltage at two poles 230V, four poles 400V, rated current to 63A line, when the person is electrocuted or the leakage current of the grid exceeds the specified value, the residual current action circuit breaker can be used in a very short time ...
|
|
CHINT/CHINT Terminal Appliance —NXHB-125 Disconnector
The NXHB-125 disconnector complies with IEC60898 and GB10963 standards. It is suitable for AC 50Hz or 60Hz, rated voltage 250V and below residential single-phase lines, to protect the overload and short circuit of electrical lines. The product has high breaking capacity, small size and a width of only 18mm. Zero, fire ...
|
|
CHINT/CHINT LAY3 series buttons
LAY3 series push buttons are suitable for electromagnetic starters, contactors, relays and other electrical circuits with AC 50Hz or 60Hz, voltage up to 380V and DC voltage up to 220V, for remote control.
Conform to the standard: GB/T 14048.5.
This article introduces the CHINT/CHINT LAY3 series press ...
|
|
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated residual operating current (I△n): 0.01A (1P+N, 2P), 0.03A, 0.05A, 0.075A, 0.1A, 0.3A (AC type); 0.03 ...
|
|
CHINT/CHINT Terminal Appliance —NU210-40 Surge Protector
NU210-40 is a surge protective device with short circuit protection. Connect to circuits and devices with an AC rated voltage of 230/400V, 50Hz. Able to protect terminal electrical equipment from the impact of induced lightning, it has the ability to protect against indirect lightning and direct lightning effects or other transient overvoltage surges.
|
|
CHINT/CHINT Terminal Appliances —NB7 Series Miniature Circuit Breaker
NB7 series miniature circuit breaker is suitable for overload and short circuit protection in the line of AC 50Hz, rated voltage to 400V, rated current to 63A, can be used as infrequent operation conversion of the line under normal circumstances, and can also be used as an isolation switch for disconnecting the line for line and equipment maintenance.
|
|
CHINT/CHINT AL-X3H alarm contact
The AL-X3H alarm contact conforms to GB/T 14048.5 standard. It is mainly used in lines with AC rated voltage to 415V or DC rated voltage to 130V, and assembled with NBH-125 series circuit breaker for signal indication of long-distance circuit breaker fault breaking.
Alarm contact is an accessory product, assembled in ...
|
|