NL1E-63 residual current action circuit breaker (without overcurrent protection) is suitable for AC 50Hz, rated voltage 230V at both poles, 400V at four poles, rated current to 63A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect the safety of people and electrical equipment, and can also be used for infrequent conversion of the line.
The products are suitable for various places such as industrial, commercial, high-rise and residential buildings.
Comply with standards: GB/T 16916.1, IEC 61008-1, and the products have obtained CCC certification.
Main parameters and technical performance
Technical parameters item | Parameter value | Rated voltage (Ue) | 230V AC(1P+N), 400V AC(3P+N) | Rated current (In) | 25A、40A、 63A | Rated insulation voltage (Ui) | 500V | Rated impulse withstand voltage (Uimp) | 4kV | Rated residual operating current(I△n) | 0.03A | Number of poles | 1P+N、3P+N | Rated Limit Short-Circuit Current(|m) | 6000A | Rated Limit Residual Short-Circuit Current (I△m) | 6000A | Rated Switching and Breaking Capacity (Inc) | 500A(In=25, 40A); 630A(n=63A) | Rated residual on- and breaking capacity (IOc) | 500A(In=25,40A); 630A(n=63A) | Rated residual inactive current | 0.5IOn |
This article introduces CHINT/CHINT NL1E-63 residual current action circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Terminal Appliances —NU6-III Series Surge Protector
NU6-III series surge protector (hereinafter referred to as surge protector) is used in AC 50Hz, rated working voltage 230V single-phase power distribution system, to meet the SPDIII. test, its open circuit voltage peak to 10kV (1.2/50μs), short circuit current to 5kA (8/20μs), suppress ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-225
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-160
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT NM1 Series Plastic Case Circuit Breaker (New Platform) NM1-63S
The circuit breaker is rated for insulation voltage up to 800V, suitable for AC 50Hz/60Hz, rated working voltage up to 690V (415V for 2P products and NM1-63), rated working current from 10A to 250A in the distribution network circuit, used to distribute power and protect line and power supply equipment from overload, short circuit ...
|
|
CHINT/CHINT Power Distribution Appliance NA8 Series Universal Circuit Breaker
Product Overview
NA8 series universal circuit breaker rated working current from 200A to 7500A, rated limit short-circuit breaking capacity up to 150kA, rated working voltage up to AC1140V, ambient temperature of -45 °C-+70°C, NA8 series universal circuit breaker set height ...
|
|
CHINT/CHINT NXBLE-125G residual current action circuit breaker
CHINT/CHINT NXBLE-125G residual current action circuit breaker
Rated current(In) : 63A, 80A, 100A, 125A (1P+N.2P) ;
Rated Residual Operating Current (IOn): 0.03A, 0.05A, 0.075A, 0.1A, 0.3A;
Rated Operating Voltage (Ue) ...
|
|
CHINT/CHINT soft starter NJR2-D series rated insulation voltage 660V
Introduction: NJR2-D series soft starter is based on advanced dual CPU control technology as the core, controls the thyristor module, realizes the soft start and soft stop functions of the three-phase AC asynchronous motor, and has the functions of overload, input phase loss, output phase loss, load short circuit, starting current limiting timeout, overvoltage, ...
|
|
CHINT/CHINT DZ15 Series Plastic Case Circuit Breaker DZ15-40
DZ15 series plastic shell circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated voltage of 380V, rated current to 100A circuit, as power distribution, motor overload and short circuit protection, but also as line infrequent conversion and motor infrequent start.
...
|
|
CHINT/CHINT NPM8 series metal button
NPM8 series push buttons are suitable for industrial control, instrumentation, and household appliances with AC 50Hz (60Hz), rated working voltage AC220V and below, or DC working voltage DC110V and below. It is used for the control of electrical circuits of contactors, relays and other signals, with an indication ...
|
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-63
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Terminal Block-TB Series
The TB series is suitable for connecting wires in circuits with AC 50Hz or 60Hz, rated voltage up to 600V and rated current up to 100A. This series of products is connected by screw crimping, and the wire end needs to be crimped before it can be connected to the terminal block. Screw mounting.
Comply with the standard ...
|
|
CHINT/CHINT Terminal Appliance —NUH-40B Surge Protector
NUH-40B is a surge protector with short-circuit protection function, suitable for AC 50Hz, rated voltage 230V/400V circuits and equipment, meet SPD Class II test, can protect equipment from lightning strikes or other transient overvoltage, the product has short-circuit protection function, can be used in the protector...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-125
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT HY2 series reverse switch
HY2 series reverse switch (hereinafter referred to as switch) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 380V, rated working current to 20A motor circuit, used as a direct switch on and off a single squirrel cage induction motor, so that it rotates, reverses and stops.
Compliant with standards ...
|
|
CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5000
YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Comply with the standard ...
|
|
CHINT/CHINT NSC1 Series Motion Controller NSC1-D8T
32-bit high-performance CPU, compiled execution mode, scan cycle is 10 times faster than analytical type, and the basic instruction single-step running time is 0.05μs.
Weight: 102
Power consumption: 2
Digital inputs: 8
Output voltage: 6-30VDC
Maximum inductive load: 12W
Maximum Resistance Load: Single-point maximum ...
|
|
CHINT/CHINT OVT-X1H Overvoltage Tripper
OVT-X1H overvoltage tripper is suitable for AC 50Hz, rated voltage 230V line, and NBH-63, NBH-40 series circuit breaker matching, when the tripper terminal voltage rises to the voltage protection range, the tripper action and drive the circuit breaker to automatically break, so as to achieve the overvoltage of the line...
|
|
CHINT/CHINT DZ20 series plastic case circuit breaker
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT XF9J alarm auxiliary contact
XF9J alarm auxiliary contact is suitable for the line with the agreed heating current to 6A, AC rated voltage to 415V or DC rated voltage to 130V, and it is assembled with NB1 miniature circuit breaker or NB1L residual current action circuit breaker for signal indication of long-distance circuit breaker on/off.
Compliant with standards ...
|
|
CHINT/CHINT OVT-X3 overvoltage tripper
Rated working voltage (Ue): AC 230V, 50Hz;
Rated insulation voltage (Ui): 500V;
Overvoltage action setting value (Uo): 280 (1+5%)V;
When the main circuit voltage is 230 (1+5%)V, the trip device should be able to keep the circuit breaker working for a long time. When the main circuit voltage rises ...
|
|