CHINT/CHINT NVF5-GS series inverter has a maximum power of 45KW

Create Date: 2024-8-30 12:03:23|Source: CHINT/CHINT

  • Brand:
    CHINT/CHINT
    Origin:
    chekiang
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    NVF5-GS series
    Product Introduction
    CHINT/CHINT NVF5-GS series water supply inverter has a maximum power of 45KW, a frequency range of (47-63) Hz, and a voltage: 0-rated input voltage
Product Description
Introduction: NVF5-GS series water supply inverter is a small size, cost-effective water supply inverter tailored by CHINT for the water supply industry. The product supports fixed frequency conversion mode, cyclic frequency conversion mode, soft stop and emergency stop function, overpressure protection function, sleep function, sleep pump control function, inlet pool water level control function, sewage function, fire mode and other functions. In addition to the above functions, it also has the functions of timing rotation, regular daily timing giving function, designated day timing giving function, fire inspection and other functions, and can control up to 9 pumps at the same time (fixed frequency conversion mode).
CHINT/CHINT NVF5-GS series inverter has a maximum power of 45KW

peculiarity

1. Wide voltage design: three-phase 380-440V: 380V(-15%)-440V(+15%).

Power range: 1.5KW-45KW

2. Multi-pump control: fixed frequency conversion mode and circulating frequency conversion mode, up to 1 variable frequency pump + 8 power frequency pumps or 3 variable frequency pumps of the water supply system.

3. Measures to deal with instantaneous power failure: instantaneous stop function, when the system has a power failure, the inverter makes the motor in a state of power generation, so that the bus is electrified

The voltage is maintained at the instantaneous power failure action to judge the voltage, and the inverter is prevented from stopping due to the undervoltage fault caused by the short-term input voltage cut-off.

4. High environmental adaptability: optional protection kit to achieve IP22 enclosure (NVF5-1.5GS - NVF5-7.5GS).

5. Obvious power saving: adjust the speed according to the water supply system, always run in the high-efficiency area, when the system flow rate is low, the inverter sleeps, and the flow rate

After the increase exceeds the set value, the inverter wakes up, and the power saving is obvious, which can save 20%-55% more power than the power frequency constant speed water pump.

Product parameters

input

Voltage range: three-phase 380 - 440 V: 380 V (-15%) - 440 V (+15%)

Frequency range: (47-63)Hz

output

Voltage: 0—Rated input voltage

Frequency: (0-400)Hz

Overload capacity: 120% rated current for 1 minute, 150% rated current for 3 seconds

The main control performance

Control mode: SVC control (no PG vector control), V/F control

Starting torque: SVC control: 150% rated torque at 0.5Hz; V/F control: 1Hz, 100% rated torque

Carrier frequency: 1kHz - 15kHz

Speed control ratio: SVC control: 1:100, V/F: 1:50

Speed control accuracy: ±0.5% of the maximum speed

Frequency Resolution: Digital Setting: 0.01Hz, Analog Setting: Maximum Frequency×0.5%

V/F curves: (linear, multi-point) V/F curves; (2, 1.7, 1.2, ) power drop torque curve

Acceleration and deceleration curves: 4 kinds of linear acceleration and deceleration, S-curve acceleration and deceleration

Basic functions: over-velocity protection, over-voltage stall protection, torque limiting, speed tracking, simple PLC, process PID, multi-stage speed control, slip automatic compensation, automatic torque lifting, pre-excitation function, instantaneous stop non-stop function

Special functions for water supply: built-in real-time clock function, fixed frequency conversion mode, cyclic frequency conversion mode, fault rotation function, shutdown function, timing rotation function, overpressure protection function, sleep function, sleep pump control function, inlet pool water level control function, sewage discharge function, regular day timing given function, designated day timing given function, fire inspection function, fire mode function

Peripheral interfaces

Digital inputs: 4 multi-function digital programmable inputs (standard); 1 high-speed pulse input terminal (NVF5-11GS - NVF5-45GS)

Digital output: 1 multi-function digital programmable output (up to 100kHz) (NVF5-11GS - NVF5-45GS)

Analog input: 2 analog signal inputs, optional (0-20)mA, (4-20)mA current signal input or (-10-+10)V, voltage signal input (NVF5-1.5GS-NVF5-7.5GS AI2 current type needs to be customized)

Analog output: 1 analog signal output, (0-20) mA, (4-20) mA current signal output or (0-10) V voltage signal output can be selected respectively

Relay output: 2 relay outputs, 1 normally open and normally closed, 1 normally open. Contact Capacity: NO 5A /NC 3A 250V (AC)

Communication interface: standard RS485 communication, expandable with a variety of communication protocols, external remote operation panel;

Braking function: NVF5-1.5GS - NVF5-2.2GS optional built-in braking unit, NVF5-3.7GS - NVF5-45GS standard built-in braking unit

Operation panel: display more than 20 parameters such as set frequency, output frequency, output voltage, output current, etc

Expansion card for water supply (optional): 6-way normally open relay, contact capacity: NO 5A 250V (AC)

Protection function: over-current protection, over-voltage protection, under-voltage protection, over-temperature protection, overload protection, input phase loss protection, output phase loss protection, load loss protection, motor short-circuit protection to ground,

Pipeline overpressure protection, relay action fault protection and other protection functions

Applicable environment

Place of use: indoor, not exposed to direct sunlight, no dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt

Altitude: normal use below 1000 meters; For derating above 1000 meters, 10% of the rated power will be derated for every 1000 meters, but not more than 3000 meters

Ambient temperature: (-10-+45) °C (ambient temperature at (45-50) °C, derating 1% for every 1 °C)

Humidity: (5-95)%RH, no condensation of water beads

Vibration: Vibration acceleration ≤ 5.8m/s²

Storage temperature: (-40-+70)°C

structure

Protection level: IP20 as standard, NVF5-1.5GS - NVF5-7.5GS can reach IP22 after optional protection kit

Cooling method: fan cooling

Material: NVF5-1.5GS - NVF5-22GS molded case structure; NVF3-30GS - NVF5-45GS metal shell structure

Installation: ≤ 2.2kW rail and wall mounting, > 2.2kW wall mounting

We will provide customers with high-quality products and satisfactory services with honest and trustworthy, convenient and fast business methods and strict management.

This article introduces CHINT/CHINT NVF5-GS series inverter with maximum power of 45KW products, if you are interested in CHINT/CHINT inverter, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
More on that
CHINT/CHINT NVF5 series inverter No PG vector CHINT/CHINT NVF5 series inverter No PG vector

Introduction: NVF5 series simple vector inverter, using no speed sensor vector control technology, has the characteristics of small and lightweight, fast operation and excellent performance.   Product parameters input Voltage range: single-phase 230V (±15%) three-phase 380V (-15%) - 4 ...

CHINT/CHINT Motion Controller NSC1 Series Weight 102g CHINT/CHINT Motion Controller NSC1 Series Weight 102g

Introduction: NSC1 series motion controller has 2 communication ports, 1 RS232, 1 RS485; Two or four single-phase high-speed pulse counting, up to 200KHz respectively, one or two AB phase high-speed pulse counting, up to 200KHz; External real-time clock chip is used to make the clock more accurate; ...

CHINT/CHINT NC7 Series AC Contactor Free air heating current 20A CHINT/CHINT NC7 Series AC Contactor Free air heating current 20A

Introduction: CHINT/CHINT AC contactor NC7-09 (hereinafter referred to as contactor) is mainly used for AC 50Hz (or 60Hz), rated working voltage to 690V, in the AC-3, 400V use category rated working current to 620A circuit, mainly used for long-distance connection and breaking circuits...

CHINT DZ47-60M plastic case circuit breaker CHINT DZ47-60M plastic case circuit breaker

DZ47-60M plastic shell circuit breaker is suitable for AC 50Hz, rated voltage to 400V, rated current not more than 63A in the distribution line; It can also be applied to distribution lines where the DC voltage does not exceed 110V at one pole, 220V at both poles, and the rated DC current does not exceed 63A. The circuit breaker is in ...

CHINT/CHINT switch NXZB/NXZHB series shell frame current 63A CHINT/CHINT switch NXZB/NXZHB series shell frame current 63A

Introduction: NXZB/NXZHB series automatic transfer switch electrical appliances are suitable for AC 50Hz, rated voltage 400V/415V and below, rated current to 63A three-phase four-wire dual-circuit power supply grid, automatically connect one or several load circuits from one power supply to another, in order to ensure the load circuit ...

CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-100 CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-100

DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...

CHINT AX-X1H auxiliary contact CHINT AX-X1H auxiliary contact

AX-X1H auxiliary contact is mainly used in lines with AC rated voltage to 415V or DC rated voltage to 130V, and is assembled with NBH-40 and NBH-63 series miniature circuit breakers for signal indication of long-distance circuit breakers. The auxiliary contact is an accessory product.

CHINT/CHINT OUVT-X1 over/undervoltage tripper CHINT/CHINT OUVT-X1 over/undervoltage tripper

Rated working voltage (Ue): AC 230V, 50Hz; Overvoltage action setting value (Uo): 280(1±5%)V; Undervoltage action setting value: (35%-70%) Ue; Rated insulation voltage (Ui) : 500V; Trip characteristics: Tripper combined with NXB-63 series circuit breaker ...

CHINT/CHINT NXBFLE-32 residual current action circuit breaker CHINT/CHINT NXBFLE-32 residual current action circuit breaker

NXBFLE-32 residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 32A in the line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on and off under normal circumstances. The product conforms to IEC61009-1, GB/T...

CHINT/CHINT NB1L-40□ residual current action circuit breaker CHINT/CHINT NB1L-40□ residual current action circuit breaker

NB1L-40 □ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 40A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...

CHINT/CHINT uninterruptible power supply GP-UPS series cabinet industrial machine CHINT/CHINT uninterruptible power supply GP-UPS series cabinet industrial machine

Introduction: GP-UPS series online uninterruptible power supply is an online UPS model with power frequency three in and three out or three in and out of line. This series of UPS adopts the high-frequency double-conversion structure of output isolation transformer and advanced all-digital control technology to achieve stable, clean and uninterruptible power supply output. At the same time ...

CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/11 CHINT/CHINT NCH8G Household AC Contactor NCH8G-25/11

NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control household ...

CHINT DZ158LE-125□ Residual Current Operated Circuit Breaker CHINT DZ158LE-125□ Residual Current Operated Circuit Breaker

DZ158LE-125□ residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two-wire, two-pole 230V, three-pole, three-pole four-wire, four-pole 400V rated current from 63A to 125A line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action is broken.

CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-250 CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-250

CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...

CHINT/CHINT AX-7 auxiliary contacts CHINT/CHINT AX-7 auxiliary contacts

AX-7 auxiliary contact is mainly used in the line of AC 50Hz, the agreed heating current to 3A, the AC rated voltage to 415V or the DC rated voltage to 125V, and is assembled with the NB7 miniature circuit breaker for the signal indication of the long-distance circuit breaker on/off. Standards: GB/T 14048.5, IEC...

CHINT/CHINT NA8G series universal circuit breaker CHINT/CHINT NA8G series universal circuit breaker

NA8G series universal circuit breaker (referred to as circuit breaker) has a rated current from 200A to 6300A, rated working voltage AC 415V, 690V, suitable for AC 50/60Hz, mainly used in the power distribution network, used to distribute electric energy, protect lines and power supply equipment, so as to protect from overload, undervoltage, short...

CHINT/CHINT NXCQ contactor type mechanical emergency starter CHINT/CHINT NXCQ contactor type mechanical emergency starter

Product Overview NXCQ series contactor emergency start device is a product specially designed and developed for fire water supply system, with the function of manual mechanical emergency start fire pump, in line with GB/T50974-2014 "Technical Specification for Fire Water Supply and Fire Hydrant System" for manual mechanical emergency starting.

CHINT/CHINT YBLX-WL Series Travel Switch YBLX-WL/CA12 CHINT/CHINT YBLX-WL Series Travel Switch YBLX-WL/CA12

YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program. Accord with...

CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V CHINT/CHINT Miniature Circuit Breaker NXB-125G Quota voltage 230V

Introduction: CHINT/CHINT miniature circuit breaker NXB-125G is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection Product parameters ...

CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-63 CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-63

CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top