Delixi Electric rushed to the front line of the anti-epidemic in various places

Create Date: 2024-8-30 12:03:23|Source: Delixi

On March 12, Delixi Electric partner Qingdao Hengtong Ruide received an order, continued to deploy a batch of components to be shipped to Laixi cabin hospital, Delixi Electric strategic cooperation plant Qingdao Fengtai Electric overnight deployment, 24 hours smoothly completed handover, escort for Qingdao war epidemic.

                               Delixi Electric rushed to the front line of the anti-epidemic in various places

On March 16, Delixi Electric joined hands with partners Shenyang Zhongyeda and Liaohe Electric Plate Factory to urgently distribute power distribution cabinets for the temporary barrier cabin hospital in the high-tech zone, which was handed over within 3 days, and the supply of goods was transmitted in the snow to ensure the power operation of the hospital.

On March 19, the confirmed cases of the epidemic in Quanzhou and asymptomatic infections increased sharply, the Quanzhou municipal government urgently needed to establish 1500 "barrier cabins" in a fast time, and asked to hand over a batch of power distribution components and distribution cabinets within 3 days, Delixi Electric fully cooperated with the panel factory, on March 19, it was equipped with 1044 units required by the Beifeng cabin hospital and 36 distribution cabinets required by Jinjiang urgent barrier point, which were urgently transported to the construction site and built at full speed the supporting force behind the "epidemic".

At the same time, Delixi Electric and its partners also helped the Langfang International Convention and Exhibition Center Hall B cabin barrier hospital and other places to fight the epidemic in the front line, helping to fight the epidemic across the country.

As a temperature of the low-voltage electrical leader, Delixi Electric will always carry forward the belief and courage of our brand's fearless and selfless dedication, and show the hard core strength and mission of our enterprises with actions. May the mountains and rivers be safe and the world be safe!
More on that
Resistance quantization circuit exerts resistance to the flow of current – Delixi Resistance quantization circuit exerts resistance to the flow of current – Delixi

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). When it comes to metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. The standard unit of resistance is ohms, there are ...

Delixi solid state relay relative to AC contactor characteristics Delixi solid state relay relative to AC contactor characteristics

Delixi solid state relay and Delixi communication contactor are more used products, so what are the advantages of solid state relay relative to communication contactor, how should we choose when we can choose? 1. First of all, the solid ...

Delixi low-voltage AC contactor can not be suction reason Delixi low-voltage AC contactor can not be suction reason

AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.

The choice of circuit breaker for motor protection - Delixi The choice of circuit breaker for motor protection - Delixi

Class I refers to the circuit breaker, which is only used for maintenance and not for normal operation; The other is that circuit breakers are required together for maintenance and infrequent operation. In the latter case, the operating conditions and electrical life should be taken into account. The selection principles for circuit breakers for motor maintenance are as follows: ...

Delixi switching regulator basics Delixi switching regulator basics

1. What is a switching regulator? Switching voltage regulators, some people call it regulators, voltage regulator sources. Complete voltage regulation, is the demand control system (negative feedback), from the automatic control theory we know that when the voltage rises, it will be lowered through negative feedback, and when the voltage drops, it will be ...

The common sense principle of the inverter - Delixi inverter The common sense principle of the inverter - Delixi inverter

The fuses should be installed on the lines of each phase. It is strictly forbidden to install fuses on the neutral line of the two-phase three-wire or three-phase four-wire circuit. Fuses are mainly used for short-circuit maintenance. When the fuse is used for blocking purposes, the fuse must be installed.

Delixi inverter Delixi inverter

Delixi inverter has launched CDI9000 series inverter, CDI9100 series inverter, CDI9100-S series inverter, CDI9200-G series general-purpose inverter, CDI9200-P series fan pump inverter, CDI9200-ZS series injection molding machine special inverter, CDI9200-GS series ...

The difference between Delixi LDO and DC-DC The difference between Delixi LDO and DC-DC

The so-called DC-DC is actually DC to DC voltage, of course, LDO is also a kind of DC-DC, and only LDO can only achieve step-down. The general DC-DC is mainly converted from DC to AC communication through the self-excited vibration circuit inside, so the external inductance and capacitor are required to achieve LC vibration (and LDO is only ...

How to solve the data running flight of Delixi inverter controller How to solve the data running flight of Delixi inverter controller

Problem depiction: Delixi inverter controller data flying, or the data is occasionally incorrect, how to solve? Solution(s): This is the result of severe disturbances to the controller. Frequently...

Delixi participated in the 4th China Electrical Appliance Culture Festival Delixi participated in the 4th China Electrical Appliance Culture Festival

On January 27, the "4th China Electrical Appliance Culture Festival and World Electrical Products Expo" was grandly opened in Liushi, Wenzhou, the capital of China's electrical appliances. More than 500 companies from home and abroad showed their faces on more than 1,400 booths. The largest Delixi exhibition hall with a booth area of more than 1,800 square meters ...

Delixi EM61 series inverter features Delixi EM61 series inverter features

EM61 series inverter has optimized open-loop vector control, V F control, stable performance, optimized function, standard equipment for users, and can also expand multi-channel I-O interface and communication function, which is a compact low-power model. ...

How to wire and use the number of switches when the inverter starts and stops - Delixi How to wire and use the number of switches when the inverter starts and stops - Delixi

The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...

Characteristics and parameters of industrial molded case circuit breaker - Delixi Characteristics and parameters of industrial molded case circuit breaker - Delixi

1. Extra limit short-circuit breaking can be used for Icu There are two types of breaking capacity targets for circuit breakers: additional limit short-circuit breaking capacity of 4U and additional operating short-circuit breaking capacity Ics. As a characteristic parameter, ICS is not only a brief consideration of the breaking ability of the circuit breaker, but also a breaking purpose.

Delixi leakage protector DZ47sLES advantages Delixi leakage protector DZ47sLES advantages

Delixi leakage maintainer, as a common anti-shock equipment, can quickly disconnect the circuit in the face of leakage, overload, short circuit and other problems in the electrical circuit, useful maintenance personnel safety, to prevent damage to electrical equipment. Volume...

Delixi E series inverter common fault analysis Delixi E series inverter common fault analysis

Fault phenomenon, fault description, detailed description of troubleshooting measures No display at power-on, no display, no display Check whether the power wiring is correct; Check whether the 5V power supply is normal; Check whether the keyboard is in good contact with the control board; Check whether the control panel and keyboard are normal. If you use ...

The reason why the Delixi switch socket is hot and hot The reason why the Delixi switch socket is hot and hot

1. The quality of the socket is low First of all, we should check whether the socket is a miscellaneous defective product, the copper clamping force in the defective socket is not enough, resulting in a poor connection between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. Therefore, you must not buy cheap miscellaneous electric ...

Delixi time control switch how to adjust the control time Delixi time control switch how to adjust the control time

1. Check the time first, if the time of the week, hour and minute is correct, don't care. If it's not correct, you need to take care of it yourself. Conditioning is very simple, you just need to press the clock, and then adjust the week by week, the hour of conditioning, and the minutes of conditioning. ...

Delixi molded case circuit breaker Icu=ICS understands Delixi molded case circuit breaker Icu=ICS understands

Delixi 3P air switch, rated current 630A, rated voltage 380V. The Icu=Ics=70kA of this circuit breaker. When the short-circuit current reaches 70kA, can the circuit breaker still be used? If it works, the ICU is already at its limit, which is a contradiction. If it can't be used, ICS is 70KA, which means ...

Delixi product installation, operation and maintenance instructions Delixi product installation, operation and maintenance instructions

Normal conditions of operation, installation, and transportation 1 Normal operating conditions Appliances that meet the rules of this code should be able to operate under the following conditions. Note: See Appendix B for the requirements of non-standard application conditions. Non-standard ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top