Delixi leakage maintainer, as a common anti-shock equipment, can quickly disconnect the circuit in the face of leakage, overload, short circuit and other problems in the electrical circuit, useful maintenance personnel safety, to prevent damage to electrical equipment.
Smaller size, space-saving, faster selection
The new channel is born to meet the actual needs of continuous addition, multi-standard small size, saving device space and reducing the cost of the cabinet.
Delixi leakage maintainer, the volume is reduced by 30%-50%, saving the cost of device space and cabinet, improving the customer's warehousing and transportation capabilities, and effectively reducing the cost of operation and maintenance
Three sizes, modular planning, faster selection and planning
25m㎡ large hole wiring is more convenient
Delixi leakage maintainer, wiring can be improved to 25mm², large hole wiring is more convenient, improve the wiring power of workers, reduce labor costs.
The full range of 25mm² large-hole wiring is more convenient for wiring and can effectively improve the wiring power
1P+N and 2P supply two standards for upper and lower incoming lines, and the wiring is faster
Comprehensive leakage maintenance to cover up more widely and safely
Leakage maintenance covers various types of communication leakage and pulsating DC leakage, and the new standards meet more application needs and maintenance is more comprehensive.
The full range of A/AC type leakage can be used for computers, microwave ovens, induction cookers, washing machines, refrigerators, charging piles and other electrical appliances, with more comprehensive maintenance
The new 10mA leakage standard makes the leakage maintenance of similar places such as bathhouses and kitchens more sensitive and safer
Patented skills Casting strengthens and maintains barriers
Certified patented skills are deployed with multiple protection plans, firmly locking the risk elements of the power system, and not giving the risk a chance to take advantage of it.
The anti-blowout arc baffle is planned to prevent the arc from flying out of the handle and ensure the safety of the operator
The rapid contact closure planning reduces arc pulling, reduces the ablation of the contact, and makes the component more durable and reliable
Built-in reliable magnetic tripping mechanism, quickly break the short-circuit current, to ensure the safety of equipment and human body
Planning and promotion and quality progress are exquisite
DZ47sLES Delixi leakage maintainer, from the inside to the outside to improve the sense of use, structure, touch, durability ...... Every side of your attention is taken care of.
DZ47sLES 3P/3P+N/4P is fixed with 6 rivets, which is strong in assembly and stronger in resistance to high-current impact
The DZ47sLES monopole handle is enlarged, making the operation more comfortable and labor-saving, and the number of poles of the product is more eye-catching and easy to identify
It can be used stably in the environment of -35°C-70°C, and can operate freely from the north where water is condensed into ice to the high-temperature scorching Hainan
Each side is the advantage of Delixi leakage maintainer, DZ47sLES calmly reflects the complex and changeable electricity environment, leakage maintenance can not tolerate a trace of carelessness. Delixi Electric Navigator series is not limited to the glory of the past, meticulously carved to promote innovation, for the safety of low-voltage power distribution to build a solid barrier. |
More on that
|
Introduction of four-quadrant regulator - Delixi
A four-quadrant power supply is a power supply capable of absorbing and supplying positive and negative currents and voltages. While a simple voltage converter is capable of generating a fixed output voltage from the input voltage, this feature is not sufficient in some applications. An example is the control of voltage nodes connected to capacitors that ...
|
|
Delixi parameter voltage regulator performance and advantages
1. Its overall inductive skills function is the best, its design does not use electronic equipment, and the environmental adaptability and stability and reliability function are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...
|
|
Delixi molded case circuit breaker Icu=ICS understands
Delixi 3P air switch, rated current 630A, rated voltage 380V. The Icu=Ics=70kA of this circuit breaker. When the short-circuit current reaches 70kA, can the circuit breaker still be used? If it works, the ICU is already at its limit, which is a contradiction. If it can't be used, ICS is 70KA, which means ...
|
|
Delixi solid state relay introduction
What is a Solid State Relay
Solid State Relay (SSR) is a pointless switch composed of microelectronic circuits, discrete electronic devices, and power electronic power devices. The barrier between the control end and the load is completed by a barrier device. The input of the solid state relay is micro...
|
|
Delixi universal circuit breaker CDW9 series maintenance operation
Delixi intelligent all-round circuit breaker CDW9 series, should be checked regularly every year, first open and close and long-distance equipment, successively use a variety of additives, test operation program column, control unit test using a small test suite; Every two years or when the control unit repair target reaches 100, it should be ...
|
|
Delixi integrated voltage regulator knowledge
The role of a voltage regulator is to convert an unstable DC voltage into a stable DC voltage. The integrated voltage regulator has a wider and wider range of applications due to its advantages such as small size, good voltage regulation performance and perfect maintenance function. There are two types of integrated voltage regulators: linear power supply regulators and switching power supply regulators.
|
|
Precautions for instrument maintenance - Delixi
1. When using a multimeter ohm, remember not to measure with electricity.
2. When using the logic pen and oscilloscope to detect the signal, it is necessary to pay attention not to make the probe contact the two measurement pins together, because the essence of this situation is to constitute a short circuit in the case of power-on.
3. Detect filtering in the power supply ...
|
|
Delixi built-in bypass soft starter CDRA-K3 series features
1. A variety of starting methods
Current limiting soft start, voltage ramp soft start, ramp plus current limiting soft start.
2. High reliability
Signals in the control system are digitized by high-performance microprocessors.
...
|
|
Resistance quantization circuit exerts resistance to the flow of current – Delixi
We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). When it comes to metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal.
The standard unit of resistance is ohms, there are ...
|
|
Reducer troubleshooting method - Delixi
01 "O" ring spell
In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings.
O-rings are a very common type of product sealing planning.
|
|
Delixi contactor selection considerations
Electrical safety is not a trivial matter in modern society. Delixi communication contactors are used in homes, public places or commercial buildings. As a power device, its importance is self-evident. If you buy an unsuitable communication contactor, it will appear briefly in the future application process ...
|
|
The difference between Delixi high-voltage circuit breaker and disconnector
The high-voltage circuit breaker (or high-voltage switch) is the primary power control equipment of the substation, which has arc extinguishing characteristics. When the system is in normal operation, it can intercept and connect the no-load and load currents of lines and various electrical equipment. When there is a problem in the system, it can quickly block the fault with the cooperation of relay maintenance.
|
|
Inverter maintenance technology - Delixi inverter
(1) Fault characteristics
a) *** tripping may occur during operation, but if it is restarted after resetting, it often trips as soon as the speed rises.
b) has a large inrush current, but most drives can already be tripped, maintenance without damage. Due to the ...
|
|
The reason why the switch socket is hot - Delixi
1. The socket quality is low quality
First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...
|
|
Delixi linear and switching regulators introduced
01. What is a linear voltage regulator?
A linear regulator uses a transistor or FET operating in its linear region to subtract the excess voltage from the input voltage of the application to produce a conditioned output voltage.
The so-called voltage drop voltage means that the voltage regulator maintains its output voltage at its ...
|
|
Delixi inverter CDI-E180 series of introduction
Product Introduction
With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, rich functions, it is a high-performance vector inverter, which can be widely used in speed control accuracy, torque echoing speed, ...
|
|
Delixi voltage regulator fault phenomenon
Delixi regulator output voltmeter keeps swinging back and forth, and sparks occur at the carbon brush, and the problem phenomenon and cause analysis
1. The contact pressure between the carbon brush and the coil plane is too small
2. The carbon brush is severely worn
Delixi voltage regulator has ...
|
|
How to solve the data running flight of Delixi inverter controller
Problem depiction:
Delixi inverter controller data flying, or the data is occasionally incorrect, how to solve?
Solution(s):
This is the result of severe disturbances to the controller. Frequently...
|
|
Why use optocouplers in circuits - Delixi
Requirements for electrical barriers. Between A and B circuits, signal transmission is required, but because of the disparity between the power supply levels of the two circuits, one is hundreds of volts, and the other is only a few volts; Two very different power supply systems, unable to share the power supply;
...
|
|
How to wire and use the number of switches when the inverter starts and stops - Delixi
The control of the inverter is nothing more than the fundamental logic of starting, aborting, forward rotation, rotation, and speed regulation, which fundamentally requires that the level condition is effective, rather than the rising edge is effective, so the use of button switches to control the inverter is generally required to use the self-protection of the button...
|
|