Schneider turbine flowmeter selection considerations

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1. According to the requirements of measurement intention:

It is required to select the instantaneous flow rate or the cumulative flow rate (cumulative flow), the unit of flow display, measurement accuracy, repeatability, linearity, flow scale and scale, measurement temperature, pressure loss, temperature and pressure compensation, output signal characteristics and response time, etc. Different measurement targets have their own measurement intentions, and have different emphases in the function of turbine flowmeters.

                               Schneider turbine flowmeter selection considerations

2. Requirements for measuring the properties of the medium:

Chemical corrosion and fouling, the chemistry of the fluid can sometimes be the determining factor in the selection of measurement methods and appearances. Some fluids can cause corrosion of surface contact parts, surface fouling, or electrolytic chemistry on the metal surface of the crystal.

3. Requirements for measuring the phase of the medium:

Depending on whether the measurement medium is a single phase change medium, or whether it is a multiphase and multi-component activity, it should be treated with caution. The turbine flowmeter can measure a single clean medium, and the electromagnetic flowmeter can measure the solid-liquid two-phase mixed medium.

4. Turbine flowmeter is a common type of flow, which can measure various gases and liquids. It uses a new intelligent planning to maintain high-precision measurement when it is used. The function of the turbine flowmeter in use is superior, the service life is very long, and it has a strong anti-disturbance ability, in the use of the time, the turbine flowmeter may encounter a variety of electromagnetic disturbances, if the anti-turbulence of the flowmeter is not good enough, the measurement accuracy of the flowmeter may be affected at the time of use.

When the turbine flowmeter is in use, the power consumption is small, and the stainless steel structure is selected, which can ensure that it has a strong anti-corrosion function during the application, and it is not simply corroded, and for some corrosive media, the turbine flowmeter can also be measured well and will not be restricted. This turbine flowmeter is very small, if there is a problem during use, it is very simple to disassemble the flowmeter, which is convenient for the user to repair in time, and after daily use, when the flowmeter needs to be cleaned, simple disassembly and assembly also makes it more convenient for the user to clean

5. Measurement accuracy requirements:

It is necessary to have a clear overall measurement accuracy requirement and whether it is used under a specific flow rate, or there is a significant change due to the change of temperature and pressure in a certain scale of measurement, and its value is generally low, and the difference between various gases is small. The commonly used accuracy grades of intelligent liquid turbine flowmeters are 1.0 and 0.5, which are higher than general rotameter flowmeters, and are a good choice for customers with high accuracy requirements.

More on that
Schneider online UPS power supply is energy-saving Schneider online UPS power supply is energy-saving

1. The need for stability When choosing UPS products, the customer's focus must be stability. For UPS, higher power means lower calorific value. Of course, only one of the primary factors that affect the internal temperature of the UPS is also to consider the heat dissipation planning of the machine itself. ...

Schneider introduces the new Lexium28S servo Schneider introduces the new Lexium28S servo

The newly launched Lexium28S Sercos III bus servo with BCH2 servo motor is available as a pre-order product portfolio to meet the needs of motion control and optimize the function of the machine. Lexium28S servo drives, available in 4 sizes, 10 models, power mask 0.05KW to 4 ...

Schneider ATV312 inverter failure Schneider ATV312 inverter failure

1. OLF is motor overload. Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong. Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...

Schneider Instrumentation Classification Schneider Instrumentation Classification

1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...

About the characteristics of Schneider explosion-proof inverter cabinet About the characteristics of Schneider explosion-proof inverter cabinet

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It mainly regulates ordinary three-phase by changing its output frequency ...

How to operate the transformer DC resistance tester – Schneider How to operate the transformer DC resistance tester – Schneider

1. The instrument test has a total of YN winding three-phase test, YN winding three-phase phase-by-phase test, low-voltage winding magnetization method test of iron-core five-column low-voltage angular transformer, low-voltage winding phase selection test and general four-terminal method of ironcore three-column low-voltage angular transformer. ...

Is there a restriction on the installation direction when Schneider installs the inverter? Is there a restriction on the installation direction when Schneider installs the inverter?

It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large in size, takes up a lot of space, and the cost is higher. This can be done by: (1) The planning of the disc should be based on the heat dissipation required by the actual device; (2) Profit ...

Schneider relay model introduction Schneider relay model introduction

RM4 Series Control Relay (Three-phase Power Control) RM4 series voltage steerable relays RM4 current operated relay RM4 level control relay RM17 three-phase power controller RM35 3-phase power control relay RM17 Voltage Steerable Relay ...

Motor control mode of Schneider inverter Motor control mode of Schneider inverter

Fundamentals of magnetic flux vector manipulation The control of a three-phase asynchronous motor is much more complicated than that of a DC motor because the current, voltage, induced potential, magnetic flux, etc., of the stator and rotor are all alternating. However, the stator winding of the three-phase asynchronous motor is a symmetrical three-phase winding, which exerts a ...

The difference between high voltage and low voltage of Schneider inverter The difference between high voltage and low voltage of Schneider inverter

1. What is the difference between high-voltage inverter and low-voltage inverter? Frequency converters can be broadly divided into two categories: high-voltage frequency converters and low-voltage frequency converters. In terms of use, the applicable objects are different, and the high-voltage motor is the same from the principle of speed regulation. From the topology ...

Schneider ATV71 inverter installation and modulation setting steps Schneider ATV71 inverter installation and modulation setting steps

1. Schneider inverter menu: (1) Simple start: Self-tuning: If the manifestation is "unfinished", then select "supplication self-tuning" until the manifestation is "finished", i.e., the completion of self-tuning; Acceleration moment: a ...

Steps for wiring and installation of rotary encoders – Schneider Steps for wiring and installation of rotary encoders – Schneider

Rotary encoder to roll the output pulse, through the counting equipment to know its position (PLC) we usually use incremental encoders, the incremental encoder output pulse signal can be directly input to the PLC, the high-speed counter of the PLC to count its pulse signal, in order to obtain the ...

Schneider inverter ATV32 acceleration and deceleration operation method Schneider inverter ATV32 acceleration and deceleration operation method

1. Use the operation method of clicking the button: In addition to the direction of travel, 2 logic inputs are required to add a speed given, e.g. LI5 is assigned the acceleration function, and LI6 is assigned the deceleration function. Then pressing LI5 will make the speed given increase, and pressing LI6 will make the speed given speed decrease ...

Introduction to Schneider inverter inverter Introduction to Schneider inverter inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to a certain law, and the motor strictly follows the dynamic and stop command action of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Pressure Reducing Valve in Instrumentation – Schneider Pressure Reducing Valve in Instrumentation – Schneider

A kind of pressure reducing valve in instrumentation refers to a kind of equipment used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...

NSX molded case circuit breaker selection - Schneider NSX molded case circuit breaker selection - Schneider

The Schneider NSX molded case circuit breaker has a double rotary contact construction for maintenance, and the high-end electronic trip unit allows for accurate measurement and easy communication. Schneider NSX molded case circuit breaker conforms to IEC60947-2, GB14048.2, China's CCC certification and multinational classification certification...

Is there still an output after the UPS power is turned off? Is there still an output after the UPS power is turned off?

1. After the UPS power supply is shut down, the output terminal is still powered, but the UPS power supply does not play a role at this time, and it is in a bypass state. 2. The power supply will not be cut off after the UPS power supply is shut down, because the UPS power supply will go bypass after the shutdown, there is still a mains power input at this time, ...

Circuit breaker failure protection - Schneider Circuit breaker failure protection - Schneider

Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.

Causes of Schneider UPS power supply damage Causes of Schneider UPS power supply damage

1. Air conditioning: It is generally forbidden to use UPS power supply, because the air conditioning is very large and belongs to the rational load. Not suitable for belt loads 2. Motor: It is necessary to choose a large-capacity UPS power supply, because it is a rational load, and it is ...

Schneider instrumentation winter insulation measures Schneider instrumentation winter insulation measures

The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on. Selection method Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top