Common faults and solutions for Rittal cabinet air conditioners

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start;

Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high.

The voltage of the air conditioner is unstable, and the compressor generally cannot start normally;

Solution: Use a multimeter to check whether the voltage and current are stable in the rated range, and if it is unstable, you can install a voltage regulator.

The external ambient temperature is too low, and the water inside the air conditioner freezes the fan, resulting in the failure to operate normally;

Solution: Check whether the fan of the outdoor unit can run normally, if it freezes, you can pour some hot water, pay attention not to pour it on the line.

If it is not cleaned for a long time, it will cause rust aging or the dust will be too thick to operate normally;

Solution: Open the shell of the outdoor unit, observe whether the inside is aging and rusty, or the dust is too thick to cause the fan to run, and clean the air conditioner regularly.

damage to the refrigeration system of the air conditioner;

Solution: Use a tester to check whether it is a short circuit in the line or a damage to the compressor.

When the air conditioner is generally not running, you can observe the screen of the air conditioner display, and when there is a failure, there will be an error code, and you can deal with it according to the instructions of the air conditioner manual, if the air conditioner does not display, it may be a problem with the line and needs to be repaired.
Common faults and solutions for Rittal cabinet air conditioners

More on that
Rittal continues to develop a new family of intelligent power distribution systems Rittal continues to develop a new family of intelligent power distribution systems

Rittal Riline Compact is a proven solution for compact power distribution systems for enclosures and small control cabinets, which is used in plant control systems in industries such as automotive, rubber, packaging machinery and renewable energies. All along, RiLin...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the principles for drawing and reading the schematic diagram of electrical control circuits? Answer: A. The schematic diagram is generally divided into power supply circuit, main circuit, control circuit, signal circuit and lighting circuit. B. In the schematic diagram, the position of the contacts of each electrical appliance is according to the ...

How to set the temperature of the Rittal air conditioner How to set the temperature of the Rittal air conditioner

1. Set the target temperature: the default temperature of the original factory is 35°C, you can press and hold the set button for more than 1 second after starting, the parameters start to flash, complete the temperature adjustment by pressing the UP and DOWN buttons, and after adjusting to the target temperature, press the set button to store the set parameters. 2. High temperature alarm: ...

Rittal enclosures – how to choose the size of the cabinet? Rittal enclosures – how to choose the size of the cabinet?

1. Determine the size of the server, such as depth size, height size (how many U), and whether it is a 19-inch rack-mounted installation. 2. Choose a cabinet according to the installation space: If the server is a 19-inch rack-mounted installation, then a standard cabinet can be used. Root...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What is the role of a DC system in a substation? Answer: The DC system provides reliable DC power supply for control signals, relay protection, automatic devices and accident lighting in the substation, and also provides reliable operating power for operation. The reliability of the DC system has a significant impact on the ...

The solution to the A17 fault reported by the Rittal cabinet air conditioner The solution to the A17 fault reported by the Rittal cabinet air conditioner

1. The Rittal air conditioner does not start when it is turned on, and the A17 is faulty. Check that the power supply voltage is 220V, normal; Detect that the battery voltage of the remote control is 3V, which is normal; Measure the fuse resistance value of the air conditioner compressor with a multimeter as infinity, which is normal. 2. The Rittal air conditioner does not start when it is turned on, and the display is not started.

Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it Analysis of the causes of the alarm code of the Rittal cabinet and how to deal with it

A01--- Rittal cabinet control cabinet door opens View: Look at the door switches in the Rittal cabinet. Solution: (1) Adjust the position of the door switch. (2) Check whether the wiring method is correct (passive normally closed point at 1.2 points). A03 --- Filter Monitor ...

Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures Rittal enclosures – the details that need to be taken into account for the daily care and maintenance of your enclosures

1. Avoid light The server is required to operate in a constant temperature environment, and direct sunlight will increase the temperature in the computer room, which will damage the display and shorten its service life. When operating in IDC and ISP data centers, it is impossible to see a ray of sunshine. So, in ...

Rittal cables – the difference between power cables and control cables Rittal cables – the difference between power cables and control cables

The power cable is used to transmit and distribute large-scale electrical energy in the main line of the power system, and the control cable directly transmits the electric energy from the distribution point of the power system to the power connection line of various electrical equipment and appliances. The rated voltage of power cables is generally 0.6/1KV and above, and the control cables are mainly 4 ...

Rittal takes you through the efficient and accurate configuration of your enclosure system Rittal takes you through the efficient and accurate configuration of your enclosure system

In the recent Winter Olympics, short track speed skating star Wang Meng helped lock the first gold medal of the Chinese team in the Winter Olympics in advance with "My eyes are rulers". So what is the "magic weapon" that can help engineers refine the "sharp eye" of error-free assembly in the assembly of Rittal cabinet systems? ...

The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder The Rittal plastic handle replaces the standard lock with or without a secure semi-circular cylinder

Product Model 2485.100 Replace standard locks with or without a secure semicircular cylinder.   Type::C Color: RAL 9011 A note on the order number: Not suitable for AE 1018.600 Lock: Cylinder: No safety cylindrical cylinder ...

Introducing the Rittal Product Configuration System (RiCS). Introducing the Rittal Product Configuration System (RiCS).

The Rittal Configurator (RiCS) is a new system configurator for the Rittal system product. It will allow you to quickly select a custom-configured cabinet that meets your application needs. During the configuration process, you can view the configuration in real time through the visual 3D model. After the configuration is complete ...

Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets

▲ GGD AC low-voltage distribution cabinet: (1) Use GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...

Rittal cables – safety requirements for cables Rittal cables – safety requirements for cables

1. When the cables cross each other, the high-voltage cable should be below the low-voltage cable. If one of the cables is protected by a pipe or separated by a partition within 1m before and after the intersection, the minimum allowable distance is 0.25m. 2. When the cable is close to or crosses the thermal pipeline, if there are thermal insulation measures, the flat ...

Rittal Rittal economy air conditioning, RBT cooling unit Rittal Rittal economy air conditioning, RBT cooling unit

Rittal has an economical air conditioner on the market, and the Rittal RBT cooling unit – is your most economical choice! If a limited budget makes you more interested in the cost Extremely sensitive, then RBT is the ideal choice for you Choose. Produced through large-scale assembly lines, as well as cold But the unit itself is excellent ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the conditions that must be met for high-voltage appliances? A: A. The insulation is safe and reliable; B. Long-term operation under rated current and certain short-term overload capacity; C. Able to carry the thermal and electrodynamic effects of short-circuit currents without damage; D. Switching electrical appliances can be safe...

Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets Rittal cabinets – the operation process of power outages in low-voltage distribution cabinets

1. Normal power transmission operation process of low-voltage distribution cabinet: 1. All load switches are disconnected, confirm that the switches have at least one breakpoint; 2. Confirm that the power switch is in the disconnected position; 3. Send the power supply to the operation circuit, and the status indication is normal; 4. The incoming switch is - isolated ...

The principle and use of Rittal cabinets The principle and use of Rittal cabinets

The Rittal cabinet principle Rittal is a Germany company that specializes in the manufacture of all kinds of cabinets. It is famous for its reasonable design and guaranteed quality. Now there are many imitations in China, and imitation Rittal is also popular. The working principle of the Rittal cabinet is to cut off the inrush current of the wire itself.

Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring Rittal cabinets - four tips for the reasonable layout of low-voltage distribution cabinet wiring

1. Site selection. The location of the low-voltage distribution room should be close to the load center, set up in a place with less dust, less corrosive medium, dry and slight vibration, and should appropriately leave room for development; Second, the layout of power distribution equipment. The layout of the distribution equipment in the low-voltage distribution room must follow the principle of safety, safety, and safety.

Some advantages of the Rittal compact AE enclosure Some advantages of the Rittal compact AE enclosure

The Rittal compact AE cabinet with its new internal expansion rails –Supplementary internal expansion for machining – Can be done in a time-saving manner in the side, bottom and top cover areas Installation – Two rows of adjustable TS 8 system holes for installation capacity Outer space...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top