(1) The drawing of the wiring diagram and the wiring table shall be subject to the request of GB6988.6-1993 in the "Production of Control System Function Table Diagram".

(2) All electrical components and wires should be marked with letter symbols and wiring numbers that differ from those in the schematic diagram of the electrical circuit. The catalog number, terminal number and transmission line number of the circuit schematic diagram should be respectively applicable to GB5094-1985 electrical technology engineering code, GB4026-1992 electronic equipment terminal and special wire terminal digital code and GB4884-1985 wire identification.

(3) Different from the schematic diagram of the electrical circuit, each part of the same electrical product component (circuit breaker, electromagnetic coil, etc.) must be drawn together on the wiring diagram;

  ​                        Drawing precautions for wiring diagram of electrical components - Delixi

(4) The electrical wiring diagram is drawn with a fine wire frame. The wiring method is divided into two kinds of pre-board wiring and post-board wiring, generally using pre-board wiring, for the simple electrical control system, the total number of electrical product components is less, and the wiring is not cumbersome, and the connection between the components can be made immediately; In view of the redundant components, the total number of electrical product components is large, and the wiring is more complicated, the wire duct is generally selected, and the wiring number is indicated on the components of each electrical product, and there is no need to make the connection between the components.

(5) The wiring diagram should indicate the type standard, standard type, cross-section and color rules of various transmission lines used for wiring.

(6) When the components are connected with the external circuit, the RF connector should be used for the incoming and outgoing lines of the large cross-section transmission line, and the others should be connected through the terminal in the row.

More on that
Delixi frequency converter E series precautions Delixi frequency converter E series precautions

1. Before the inverter device is in place and debugged, please tighten the components, especially the connecting bolts of the wire part, if not tightened, the connection will be heated and cause fire. 2. The on-site planning of the installation should be reasonable, and the excellent ventilation environment should be maintained. 3. The incoming and outgoing power lines of the inverter are not ...

Delixi inverter analog output fault analysis Delixi inverter analog output fault analysis

The analog output of Delixi inverter is abnormal, and the operating frequency of the inverter does not match the output of the controller? Solution(s): First, you should determine what hardware is going wrong. Make the controller enter the manual debugging situation, respectively...

Frequently asked questions about Delixi voltage regulators Frequently asked questions about Delixi voltage regulators

Delixi voltage regulator will have a stable preset amplitude of a fixed output voltage, regardless of its input voltage or load conditions change. There are two types of voltage regulators: linear and switched The linear regulator is an active (BJT or MOSFET) operated by a high-gain differential amplifier ...

Noise characteristics of different switching regulator topologies - Delixi Noise characteristics of different switching regulator topologies - Delixi

Currently, there are many different switching regulator topologies. Some topologies are widely used, such as the classic buck converter, also known as the buck converter. However, there are also some lesser-known switch-mode DC-DC converters that include Zeta topologies. These topologies are divided into fundamental topologies ...

Choose the right inverter method - Delixi Choose the right inverter method - Delixi

The type of inverter is selected according to the type of production machinery, speed regulation range, static speed accuracy, and starting torque requirements, and it is most appropriate to decide which inverter is the most suitable to use. The so-called suitability is not only easy to use, but also economical, to meet the basic conditions and requirements of technology and production. ...

Delixi universal circuit breaker CDW9 series maintenance operation Delixi universal circuit breaker CDW9 series maintenance operation

Delixi intelligent all-round circuit breaker CDW9 series, should be checked regularly every year, first open and close and long-distance equipment, successively use a variety of additives, test operation program column, control unit test using a small test suite; Every two years or when the control unit repair target reaches 100, it should be ...

Precautions for the use of Delixi leakage protector Precautions for the use of Delixi leakage protector

1. If the two branch lines are connected, the current in the zero line flows to each other, which destroys the operating current balance in the zero sequence current transformer and causes the leakage maintainer to malfunction. If you want to use the neutral line of the power branch line as the neutral line of the lighting branch line nearby, it will cause the leakage of the power branch line.

Delixi circuit breaker operation failure Delixi circuit breaker operation failure

Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the most basic and important function of the high-voltage circuit breaker is to operate correctly and remove the fault of the power grid quickly. If the circuit breaker drags or malfunctions, it will pose a serious threat to the power grid, first of all: (1)) expand the scale of the incident, which may make the original ...

Inverter maintenance technology - Delixi inverter Inverter maintenance technology - Delixi inverter

(1) Fault characteristics a) *** tripping may occur during operation, but if it is restarted after resetting, it often trips as soon as the speed rises. b) has a large inrush current, but most drives can already be tripped, maintenance without damage. Due to the ...

Delixi three-phase motor electrical control circuit principle Delixi three-phase motor electrical control circuit principle

What is the principle of the electrical control circuit of the three-phase motor? First of all, let's take a look at what is the principle of electrical control of work machinery. The schematic diagram of the electrical control circuit of the working machinery is actually connected with graphic symbols, text symbols and lines to show the connection relationship and circuit of each electrical component.

Delixi inverter parameter setting method Delixi inverter parameter setting method

P0.00: Set to G type (constant torque load type). P0.01: Set to 1 fundamental efficacy model. P0.02: Set to 1V/F control. P0.03: Set to 0 keyboard control. P0.04: Set to be given by the external terminal for multi-segment commands. ...

Delixi won the lawsuit "Delixi United" to defend its rights by legal means Delixi won the lawsuit "Delixi United" to defend its rights by legal means

  On July 14, the official Weibo of the Beijing Municipal Patent People's Court "Intellectual Property Beijing" released information that Delixi Group Co., Ltd. (hereinafter referred to as "Delixi Group") sued the former administrative department of China's State Administration for Industry and Commerce to dispute the proposal has been adjudicated in the first instance not long ago, and the appellant Delixi ...

Delixi indicator light failure and solutions Delixi indicator light failure and solutions

1. What should I do if the indicator light is on and when it is dark Generally, the reason for this situation is that the line contact is poor or the screws of the terminal are not tightened, we should check the condition of the line, connect the power cord and tighten the screws, and press the wire. ...

Servo motor failure and analysis - Delixi Servo motor failure and analysis - Delixi

1. Motor encoder alarm 1. The cause of the failure (1) Wrong wiring; (2) electromagnetic disturbance; (3) Encoder hardware damage caused by mechanical vibration; (4) Pollution caused by the on-site environment. 2 ...

The difference between an isolation switch and a circuit breaker The difference between an isolation switch and a circuit breaker

The circuit breaker has arc extinguishing equipment, so the circuit breaker can be operated with load, not only the load current, but also the fault (short circuit) current; The circuit breaker has a good package form, so simply observing the circuit breaker cannot intuitively determine whether it is in the closed or disconnected position. Isolate ...

Delixi circuit breaker common model features Delixi circuit breaker common model features

CDB1 miniature circuit breaker is a current-limiting high-breaking miniature circuit breaker with overload and short-circuit maintenance, which is suitable for communication 50Hz, additional voltage 400V and below, additional current 63A and below circuits, as line overload and short circuit maintenance, can also be used under normal circumstances.

Delixi voltage regulator working principle Delixi voltage regulator working principle

In Delixi voltage regulator, the voltage correction from and under voltage conditions is performed through two basic operations, namely Oersted and step-down operation. These operations can be switched on and off manually or automatically by electronic circuits. Under voltage conditions, the voltage of the boost operation is increased to the rated voltage.

Reducer troubleshooting method - Delixi Reducer troubleshooting method - Delixi

01 "O" ring spell In addition to the oil seal problem of the reducer itself, the robot manufacturer will also have an impact on the planning and installation of the reducer components, due to the sealing of the reducer, in addition to the oil seal, there are also O-rings. O-rings are a very common type of product sealing planning.

Delixi voltage regulator capacity and size calculation method Delixi voltage regulator capacity and size calculation method

1. Single-phase circuit single-phase power supply - power supply with a single AC electromotive force. The fundamental power supply method for civil electricity. Single-phase load – A load that is powered by a single-phase power supply. Household appliances such as lights, televisions, and electric fans are generally single-phase loads. The accounting method is as follows: a. When negative ...

Delixi inverter CDI-E180 series of introduction Delixi inverter CDI-E180 series of introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, rich functions, it is a high-performance vector inverter, which can be widely used in speed control accuracy, torque echoing speed, ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top