A detailed description of the Wiener comb busbar and connection terminals

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00

                               A detailed description of the Wiener comb busbar and connection terminals

Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar.

When there is a deviation between the installation position and the installation conditions, pay attention to the use of capacity reduction.

Degree of protection: IP20 The front can be combined with NH-fuse type disconnectors, comb busbars and connection terminals.

The degree of protection of the terminal depends on the installation method.

Touch protection: according to EN 50274/BGV A3.

Rated operating voltage: 690 V AC/440 V DC.

Rated insulation voltage: 800V when the pollution level is 2;

At a pollution level of 3, 690 V.

Rated impulse withstand voltage: 6 kV.

Rated impulse withstand current: 25 kA/400 V.

Rated short-circuit current stability: 12.5 kA-100 ms/400 V.

Size 000: Connection terminal: Cu 6 - 35 mm2 re, rm; Cu 4 - 25 f, f+AE

(maximum connection diameter 11 mm).

Cross-sectional area of comb busbar: 35 mm2.

Size 00: Connection terminal: Cu 25 - 95 mm2 re, rm; Cu 35 - 95 mm2 sm ; Cu 25 - 70 mm2 f+AE

(Pressed into a square or trapezoidal shape with a maximum connection diameter of 14 mm).

Current rating: Intermediate input 1 x 260 A / 2 x 260 A; Side input 1 x 130 A
More on that
Knowledge points of Wiener busway Knowledge points of Wiener busway

Busway was born in the United States, first put into practical use in Japan, and then spread all over the mountains and regions in prosperous countries and regions. So what is a busway? Busway is a high-current trunk tappable power supply system, usually made of a metal housing (iron or aluminum).

Difference Between Grounding Electrode and Grounding Busbar – Vernal Difference Between Grounding Electrode and Grounding Busbar – Vernal

The grounding electrode is a discharge channel that connects current or voltage to the earth, and in order to reduce the grounding resistance, the electrodes that form the grounding grid are generally used in groups. The grounding bus refers to the connecting wire that connects the current or voltage to the grounding grid, or the conductor that connects the grounding electrode into one. ...

Busway installation waterproofing work - Vernal Busway installation waterproofing work - Vernal

Most of the bus duct is the design standard for indoor use, so even if the humidity in the indoor air is relatively high, it will not have much impact on the operation of the busbar, but the bus duct enters the water during the use of the busway, which will definitely cause a certain degree of impact.

How is the Wiener bus system generally debugged in sections? How is the Wiener bus system generally debugged in sections?

Bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, most of which use bare wires or stranded wires with rectangular or circular sections. The role of the bus bar is to collect, distribute and transmit electrical energy. According to the structure, the bus bar is divided into hard busbar, soft ...

Types of busbars, conditions for the scope of application - Wiener Types of busbars, conditions for the scope of application - Wiener

1. Commonly used busbars, useful categories Busbars are divided into hard busbars and soft busbars. According to its different shapes, hard buses can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars and so on. Rectangular busbars are the most commonly used busbars and are also busbars. According to its material ...

The main components of the Wiener bus system in the distribution cabinet are composed The main components of the Wiener bus system in the distribution cabinet are composed

The Wiener bus system is divided into 40mm, 60mm, 100mm and 185mm systems according to the upper and lower spacing between the copper bars, and the ship unloader distribution cabinet mainly adopts a 60mm rectangular bus system. This is shown in the figure below. The 60mm system provides maximum operating space and maximum current with its smallest external size.

NH-Fuse Type Disconnector Instructions for Use NH-Fuse Type Disconnector Instructions for Use

When switching on and off components, you should pay attention to the following: –In accordance with VDE-0105-100, only operation by electrical professionals or persons with electrical knowledge is allowed (operation without electricity, closing, disconnecting, and replacing fuses ...).

Fuse selection method - Wiener busbar Fuse selection method - Wiener busbar

1. Select the model of the fuse according to the circuit requirements and device conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses. ...

Distribution cabinet bus connection method - Wiener Distribution cabinet bus connection method - Wiener

When users use the distribution cabinet, they must understand the circuit device of the busbar, and many users are not very well understood, so let's talk about the bus connection mode of the distribution cabinet. The bus bar is used for the internal and external electrical appliances of the distribution cabinet.

The common DC bus of the inverter system - Wiener The common DC bus of the inverter system - Wiener

1. Three-phase AC power supply inlet The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...

Ferromagnetic resonance occurs in the busbar system – Vernal Ferromagnetic resonance occurs in the busbar system – Vernal

The ferromagnetic resonance of the bus system is divided into parallel ferromagnetic resonance and series ferromagnetic resonance. Parallel ferromagnetic resonance refers to the resonance of the ground capacitance of the bus system and the nonlinear inductance of the bus electromagnetic voltage transformer (primary neutral grounding) in the neutral point ungrounded system or small current grounding system.

Technical features of Wiener closed busbar Technical features of Wiener closed busbar

The out-of-phase shut-off bus adopts a fully connected structure, with optimized design, reasonable design, stable and reliable operation. Choose either natural cooling or forced air cooling. The out-of-phase closing bus is to support the conductors of each phase bus with insulators and close them in their respective shells, and the shells themselves are electrically connected, ...

Introduction to the Wiener 3-pole adapter Introduction to the Wiener 3-pole adapter

1、32590 EQUES®30Compact Bus adapter 32 A 1 adjustable support rail 45 x 160 with conductor AWG 10 (6 mm²) 2、32591 EQUES®30Compact Bus adapter 63 A 1 ...

Introduction of busbar, busway and busway bridge - Vernal Introduction of busbar, busway and busway bridge - Vernal

generatrix In the field of electricity, the busbar can also be called the busbar, busbar, etc., most of which refer to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.

The importance of room power supply and busbar system – Vernal The importance of room power supply and busbar system – Vernal

In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the computer room. So how do you optimize ...

Introduction to the components of the busway - Vernal Introduction to the components of the busway - Vernal

Busway is a conductive equipment used for current transmission, and now the higher the building is built, the more the application of busway is required, and in many large foremen, the use of busway is also very economical and reasonable. Any machine is made up of different parts, then the busway is made up of ...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

Development of the busbar trunk system – Wiener Development of the busbar trunk system – Wiener

(1) Air-type busway Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm. (2) Secret ...

A new product has been added to the world of CrossBoard® systems A new product has been added to the world of CrossBoard® systems

A new addition to the world of CrossBoard® systems: the MOTUS® hybrid motor starter with IO-Link interface is a new networking feature in the MOTUS® IO-Link family that enables continuous communication between the control and device levels. Control the delivery of instructions, control the parameters ...

Uses and characteristics of busbar systems – Wienal Uses and characteristics of busbar systems – Wienal

The bus system is a system with standardized bus distance, which is used in low-voltage power supply and distribution switchgear and control equipment, so that the bus can play the effect of conducting electricity and supporting electrical components. The system is divided into 40, 60, 100 and 185mm ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top