The human-machine interface is highlighted TGM765L Xinjie

Create Date: 2024-8-30 12:03:23|Source: XINJE

Xinjie TGM765L a touch screen with a high-brightness display, especially suitable for outdoor occasions. In addition, it also has a wealth of interfaces, which can flexibly realize the functions of program download, transparent transmission of PLC program, data import and export, etc.

                              The human-machine interface is highlighted TGM765L Xinjie

peculiarity

Bright LCD screen

It adopts 530cd/m² high-brightness LCD screen, and the brightness is 2+ times that of the original TG series

Ultra-fast response and quick start-up

Equipped with ARM9 400MHz processor, ultra-high-speed response

Fast start-up, from power-on to entering the program, it only takes 3-5 seconds

Multiple ways to download

A variety of download methods, support USB, U disk download and Ethernet download

Penetration function

Support to download XD/XL/XG series PLC program on the touch screen to monitor the operation of the PLC program

The editing software is simple and easy to use and powerful

TouchWin editing software, rich in parts, powerful, easy to use

Interface functions and definitions

(1) Power supply: for touch screen power supply, DC24V.

(2) USB-A port: used to connect portable storage devices to USB flash drives, etc., for data import and export.

(3) USB-B port: used for screen data download.

(4) Ethernet: Communicate with Ethernet devices such as Modbus TCP.

(5) DIP switch: used for time and touch calibration, as well as some parameter settings.

(6) Download port: RS232/RS485, used to communicate with PLC and other equipment.

(7) PLC port: RS232/RS485/RS422, used to communicate with PLC and other equipment.
More on that
Application characteristics of PLC in the control of mixing plant Application characteristics of PLC in the control of mixing plant

1. High reliability The PLC adopts a series of anti-interference methods in hardware and software, so that it can be directly installed in the industrial site and operate safely and reliably, anti-magnetic, anti-seismic and dust-proof. 2. Programming is simple and easy to grasp ...

Inverter technology strategy in electromechanical control Inverter technology strategy in electromechanical control

In the process of century industry, the more top-level software and hardware planning for the suspension of frequency conversion skills, first according to the characteristics of traditional air compressor motors, comprehensively analyze the causes of energy consumption and operation characteristics, so as to plan the control of frequency conversion skills speed regulation, air skill tightening, pressure sensing skills improvement, etc.

The cause of abnormal noise of PLC input and output module - Xinjie The cause of abnormal noise of PLC input and output module - Xinjie

Input and output module, if it is the kind of relay output, it is normal to have a little movement, because the relay is a mechanical equipment, there will be a little noise during the action, but the average person can not hear it, if it is obvious, it is estimated that the relay is broken, such as a short circuit between the turns of the coil, please pay attention to: Rongji point ...

The four main functions of the PLC control cabinet - Xinjie The four main functions of the PLC control cabinet - Xinjie

1. Power switching and maintenance: There is a circuit breaker in the PLC cabinet, which is connected to the incoming power supply. In addition to making and disconnecting circuits, circuits can also be maintained for short circuits and overloads. Cut off the power supply during repairs. 2. Start and stop control function: The panel of the PLC inverter cabinet is equipped with a man-machine interface, and the inverter start and stop button ...

Quick steps to debug the inverter – Xinjie Quick steps to debug the inverter – Xinjie

1. Check the full-load power supply of the inverter (Variable-frequency Drive (VFD). 1. Ground the terminal strip of the VFD. 2. Type the switching power supply of VFD into the terminal and receive it from the switching power supply through the power switch of the leakage protector. 3. ...

Xinjie touch screen features and advantages Xinjie touch screen features and advantages

Xinjie touch screen is an extraordinary technology product developed by Xinjie Technology Company. It not only uses touchscreen skills, but also integrates cutting-edge skills in many fields such as human-computer interaction, visual arts, and information processing, bringing skills to users. ...

Why does the industry use PLC without single-chip microcomputer-Xinjie Why does the industry use PLC without single-chip microcomputer-Xinjie

First, let's talk about PLC first About PLC, don't just see the PLC module, but a variety of PLC modules + host computer channel software to form a well-structured control systemPLC module is composed of microprocessor + memory + firmware + programming to complete the modular function. PLC control system ...

The development status of human-computer interface shopping malls in China The development status of human-computer interface shopping malls in China

The development status of human-computer interface shopping malls in China China is the shopping mall with the largest demand for human-computer interface in the world, but it is not the shopping mall with the highest sales of human-computer interface products in the world.

Precautions when connecting the servo and the PLC Precautions when connecting the servo and the PLC

(1) The PLC itself should be grounded according to the specified wiring specifications and grounding conditions, and attention should be paid to prevent the use of common grounding wires with Xinjie servo, and the two should be separated as much as possible when grounding. (2) When the power supply condition ...

Application of PLC programming in CNC maintenance - Xinjie Application of PLC programming in CNC maintenance - Xinjie

CNC machine tool is the abbreviation of digital control machine tool, which is an automatic machine tool equipped with a program control system. The control system is the numerical control system, the numerical control system can logically process the program with the control code or other symbolic instruction rules, and decode it, so that the machine tool action and add ...

Internal interference in PLC remote module system - Xinjie Internal interference in PLC remote module system - Xinjie

The internal disturbances of the PLC system are mainly caused by the mutual electromagnetic radiation between the internal components and circuits of the system, such as the mutual radiation of logic circuits and their influence on the imitation circuit, the interaction between imitation and logic, and the mutual mismatch between components. How to deal with PLC long distances ...

Causes and solutions of inverter leakage - Xinjie Causes and solutions of inverter leakage - Xinjie

1. The cause of the leakage problem Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reason for this problem is explained and stated as follows. Depend on...

Internal causes and preventive measures of inverter failure Internal causes and preventive measures of inverter failure

The problem of the inverter is not only affected by external factors, but also by internal factors. 1. The inverter parameter setting is unreasonable and countermeasures to make the inverter work normally, in addition to the normal equipment, the parameter setting is also very important, if the parameter is not set properly, it will not be able to ...

Advantages of Xinjie XDM series motion control PLC Advantages of Xinjie XDM series motion control PLC

Xinjie XDM series PLC, XDM is the sports control PLC in the XD series, now has the following types: XDM-24T4-E/C, XDM-32T4-E/C, XDM-60T4-E/C, XDM-60T10-E/C. The XDM series has the following ...

False load connection method in the debugging of the inverter - Xinjie False load connection method in the debugging of the inverter - Xinjie

There are many novices who are not familiar with the false load about the maintenance inverter, and the maintenance inverter uses the false load to keep many of their modules, because the maintenance novice generally does not know how to do this, and now the electric light is on to clarify that the module is going to be broken. A dummy load is a load with a resistor of several hundred ohms ( ...

Common faults of wires and cables - Xinjie Common faults of wires and cables - Xinjie

The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are: a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality. b. Electrical: the construction process of the cable head does not meet the requirements.

The inverter controls the leakage of the motor The inverter controls the leakage of the motor

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

Superheat treatment method of Xinjie inverter drive motor Superheat treatment method of Xinjie inverter drive motor

Why does the motor driven by the inverter overheat? This is due to the fact that the voltage of the inverter drive motor contains a rich high-frequency component. The voltage waveform of the inverter-driven motor is not a sine wave voltage, but a pulse-width modulation (PWM) voltage. According to Fu Liye's analysis, this waveform ...

Introduction to PLC debugging steps - Xinjie Introduction to PLC debugging steps - Xinjie

Input and output loop debugging 1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply mode (internal power supply or external power supply) is consistent with the field instrument; Use a signal generator to add a signal to each channel at the field end, generally taking 0, 5 ...

The difference between servo and frequency conversion motors - Xinjie The difference between servo and frequency conversion motors - Xinjie

The usual inverter motor (hereinafter referred to as VFD) can only regulate the speed of the communication motor, and it can be open-loop or closed-loop, depending on the control method and VFD. This is the traditional V/F mode. The basic concept of servo is accurate, precise and fast positioning. Frequency conversion is servo ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top