There are many novices who are not familiar with the false load about the maintenance inverter, and the maintenance inverter uses the false load to keep many of their modules, because the maintenance novice generally does not know how to do this, and now the electric light is on to clarify that the module is going to be broken. The false load is to use a resistor of several hundred ohms (the bulb can also be used), string it on the main circuit, if there is a fast melting, remove it, and install the resistor; If there is no fast melting, it can be disconnected anywhere on the main return, and the resistor can be strung on it! This resistor plays a current limiting effect, when the module has a short circuit, the module will not be burned off, and the output of the inverter will be normal after starting, and then the false load will be removed!
However, there are also several problems to be paid attention to in the connection of false loads:
1. It should be connected between the capacitor and the module, not between the rectifier and the capacitor, because the capacitor discharge is enough to burn out the module.
2. When the switching power supply is fast-melting, you can't put the false load on the fast-melting, otherwise the bulb will be on after the power is sent, and the switching power supply sometimes doesn't work!
3. The false load should also be connected behind the DC voltage detection point, so that when the output of the inverter is not normal, the inverter will not jump "low voltage", and you can check which output is faulty!
The inverter has a common feature, that is, if the switching power supply of the inverter is not directly supplied from the filter capacitor of the main circuit, but from the input end is separated from the main circuit and supplied independently, if the power supply is 380V, then the best transformer is 220V (rectification) and then supply the switching power supply, although the inverter will be complicated, but its fault rate will be greatly reduced! Because a large part of the inverter is related to the switching power supply! When the DC voltage of the main circuit of the inverter is unstable for many hours when the inverter is running, if the switching power supply is supplied from the filter capacitor of the main circuit, the switching power supply is simply bad!
|
More on that
|
The reason why the inverter damages the motor bearing - Xinjie
The damage of the inverter to the motor contains two aspects, the damage of the stator winding and the damage of the bearing, this damage usually occurs in a few weeks to more than ten months, the detailed moment and the inverter brand, the motor brand, the motor power, the inverter carrier frequency, the cable length between the inverter and the motor, the ring ...
|
|
Common faults of wires and cables - Xinjie
The most direct cause of cable problems is the breakdown due to the loss of insulation. First of all, there are:
a. Overload operation. Long-term overload operation will increase the temperature of the cable, aging the insulation, resulting in breakdown of insulation and degradation of construction quality.
b. Electrical: the construction process of the cable head does not meet the requirements.
|
|
The 3rd National Industrial Robot Technology Application Skills Competition - Xinjie
On October 18, the final of the "2019 China Technology Competition - The 3rd National Industrial Robot Technology Use Technology Competition" sponsored by the Ministry of Industry and Information Technology, the Ministry of Human Resources and Social Security, the Ministry of Education, the All-China Federation of Trade Unions and the Central Committee of the Communist Youth League was officially opened in Jinan, Shandong Province.
|
|
An overview of the precise timing instructions of the Seejet PLC
Make accurate punctuality, read accurate punctuality, and stop accurate punctuality.
Watchman number. Range: T600 - T618 (T600, T602, T604...) T618, numbered even)
Punctuality.
Accurate punctuality ...
|
|
The way the PLC controller works - Xinjie
Although many relays, timers and counters are often used in the ladder diagram programs used by PLCs, PLC does not have these hardware physically, but uses memory and program programming methods to do logic control and editing, and connects external mechanical devices to make physical devices through output components.
|
|
信捷快速定位开关电源方法
开关电源(Switch Mode Power Supply,简称SMPS)因负载的短路、本身振动电路失效及保护电路的失控都将招致开关管基极无法得到开关脉冲而间断作业,这使SMPS的缺点定位困难。修理作业难度大办法 ...
|
|
信捷触摸屏特点和优势
信捷触摸屏是一款由信捷科技公司开发的非凡科技产品。它不仅采用了触摸屏技能,更是将人机交互、视觉艺术和信息处理等很多范畴的前沿技能融合在一起,为用户带来了技能体会。
...
|
|
Causes and solutions of inverter leakage - Xinjie
1. The cause of the leakage problem
Some sites use frequency converters to control the motor, which will present the problem of leakage, and the leakage voltage ranges from tens of volts to 200 volts. In view of this problem, the reason for this problem is explained and stated as follows.
Depend on...
|
|
Small PLC manufacturers introduce the classification of PLC - Xinjie
Small PLC manufacturers introduce that PLC products have a wide variety of products, and the specifications and performance are also different. The classification of PLCs is usually based on their structure, function and number of I/O points.
1. Classified by input/output points
(1) ...
|
|
Troubleshooting methods for unsuccessful touch screen penetration
A:a. Now only the TGM series touchscreen supports penetration as well as network connectivity
b. At present, the penetration function only supports the PLC class of Xinjie that supports the Xnet protocol, and other models do not support it temporarily
c. Check whether the computer has the latest version of config installed serial port equipment tool (soft ...
|
|
The difference between servo and frequency conversion motors - Xinjie
The usual inverter motor (hereinafter referred to as VFD) can only regulate the speed of the communication motor, and it can be open-loop or closed-loop, depending on the control method and VFD. This is the traditional V/F mode.
The basic concept of servo is accurate, precise and fast positioning. Frequency conversion is servo ...
|
|
快速调试变频器步骤——信捷
一、变频器(Variable-frequency Drive 简称:VFD)的满载接电源查验
1.将VFD的接线端子排接地装置。
2.将VFD的开关电源键入接线端子历经漏电保护器电源开关收到开关电源上。
3. ...
|
|
Diagram of the wiring of the servo motor of Xinjie
|
|
The cause of abnormal noise of PLC input and output module - Xinjie
Input and output module, if it is the kind of relay output, it is normal to have a little movement, because the relay is a mechanical equipment, there will be a little noise during the action, but the average person can not hear it, if it is obvious, it is estimated that the relay is broken, such as a short circuit between the turns of the coil, please pay attention to: Rongji point ...
|
|
变频器启动过载怎么调参数——信捷
电机过载在变频中不必设置过载维护参数。
变频器一般依据电机功率默许有电机过载维护的。一般是1.2倍60秒就会报过载毛病了。变频器不一样过载系数不太一样。
...
|
|
PLC input and output circuit debugging - Xinjie
1. Analog input (AI) loop debugging. Carefully check the address assignment of the I0 module; Check whether the loop power supply method (internal or external) is consistent with the field instrument; Use a signal generator to check the participating signals of each channel at the field end, generally taking three points of 0, 50% or 100%. ...
|
|
PLC如何正确接地——信捷PLC
接地的方针无非是为了平安和避免搅扰,给PLC接地的方针非必须是附加在电源及输入、输出端的搅扰,所以说精确的接地体系是PLC控制体系抗电磁搅扰的首要办法之一。接地编制有浮地编制和直接接地编 ...
|
|
Xinjie PLC failure and solution
Xinjie PLC conditions are established, why is the corresponding coil not in place? There are two possible reasons for this:
(1) The same coil may be used in multiple places to perform the double coil output, and when the double coil is output, the coil on the rear side will operate first.
(2) ...
|
|
信捷Mark点定位和贴合解决方案
Mark点又称为基准点,为表面贴装工艺中的一切过程供给一起的可测量点,确保终究的定位精度,信捷电气自主研发的定位功能,能习惯方针残缺、含糊、明暗改变等情况下的定位,能快速稳定的实现对方 ...
|
|
PLC与PAC区别——信捷
PLC是即可编程逻辑操控器的缩写,是一种具有微处理器的用于自动化操控的数字运算操控器,能够将操控指令随时载入内存进行储存与履行。