LS Power Information SHOW
Inverter fault diagnosis - LS power generation Inverter fault diagnosis - LS power generation

1. How to distinguish between heavy and light faults When there is a problem with the light, the system announces the alarm signal and the fault indicator flashes. When there is a serious problem, the system will announce the problem indicator, the problem indicator will always be on, together announce the order to break the high voltage and stop closing, and store the problem ...

Precautions for powering on the inverter after the LS power production holiday Precautions for powering on the inverter after the LS power production holiday

1. During the holiday, low temperature can easily cause the equipment to be damp, check whether the electrical equipment is dry, whether there is moisture and condensation; 2. Check whether the grounding wire is loose and whether the cable is damaged by rodents and insects; 3. Sort out the dust and oil stains, and inverter ...

LS static test to determine the fault of the inverter LS static test to determine the fault of the inverter

Generally, the general-purpose inverter roughly includes the following parts: (1) rectifier circuit; (2) DC central circuit; (3) Inverter circuit; (4) Control circuit. The static test is mainly a test of the high-power transistors (power modules) of the rectifier circuit, DC center circuit and inverter circuit. Whole...

Precautions for the selection of peripheral equipment for LS power inverter Precautions for the selection of peripheral equipment for LS power inverter

The peripheral equipment of the inverter mainly includes cables, contactors, air switches, reactors, filters, braking resistors, etc. Whether the selection of the peripheral equipment of the inverter is correct and suitable also directly affects the normal operation of the inverter and the service life of the inverter.

LS inverter frequency conversion mode LS inverter frequency conversion mode

1. The operator panel is given The operator panel is a simple frequency setting method of the inverter, and the user can directly change the set rate of the inverter through the potentiometer, digital key or rising and descending keys on the inverter operator panel. The big advantage of the operator panel is that it is simple ...

Introduction to the working principle of LS electric molded case circuit breaker Introduction to the working principle of LS electric molded case circuit breaker

Molded case circuit breakers are also known as equipment circuit breakers, all parts are sealed in plastic housings, auxiliary contacts, undervoltage trippers and shunt trippers are modular. Because of the very compact structure, the molded case circuit breaker is basically impossible to maintain. It is mostly manually operated, and the large capacity ...

LS power production contactor application LS power production contactor application

LS touchers are divided into AC touchers (voltage AC) and DC touchers (voltage DC), which are used in electricity, power distribution and consumption. Toucher broadly refers to the electrical appliances that use the current flowing through the coil to generate a magnetic field in industrial electricity, so that the contacts are closed, so as to control the load. ...

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

(1) Tripping LS electric molded case circuit breaker basically involves the tripping unit in the process of practical application, and the tripping is generally a tripping method of thermomagnetic tripping or electronic tripping. In the process of practical application, if it is a ...

The cause of the broken shaft of the motor - LS generates electricity The cause of the broken shaft of the motor - LS generates electricity

1. Improper device: The motor is not concentrious with the equipment being dragged, resulting in excessive radial load on the motor, which eventually leads to metal exhaustion. When the radial load on the extension end of the motor shaft is too large, it will cause the motor shaft to have zigzag deformation in the radial direction. When the motor rotates, the shaft's ...

The touch screen controls the inverter steps The touch screen controls the inverter steps

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

LS power generation installs the switching power supply step LS power generation installs the switching power supply step

The basic method of switching the power supply of the device requires us to carry out the corresponding installation and debugging according to the specific model and the device environment. And in the process of installation, we need to pay more attention to safety and stability to ensure the normal operation of the switching power supply. ...

The difference between multi-function and general-purpose inverters The difference between multi-function and general-purpose inverters

Multi-function inverters need to meet the following two conditions: First, it can be driven by constant torque load, regardless of the type of machine, and can ensure continuous operation even if the load fluctuates greatly. If the above conditions are not satisfied, the inverter will be easy to stop, difficult to start again, and resistant to ...

Fault analysis of servo motors – LS power generation Fault analysis of servo motors – LS power generation

1. Problem phenomenon: servo error OL, servo motor can not start, and there is abnormal sound problem analysis and possible causes: (1) Bearing damage, foreign objects falling and stuck, stator magnet bursting and falling or moving tissue jamming caused by the motor itself. (2) ...

Analysis of the problem of LS power inverter Analysis of the problem of LS power inverter

1. What is the maintenance function of the inverter? Maintenance functions can be divided into the following two categories: (1) After detecting the abnormal situation, the correction action is automatically carried out, such as overcurrent loss speed avoidance, regeneration overvoltage stall avoidance. (2) Block the PWM control signal of power semiconductor equipment after detecting the abnormality ...

Relationship between motion control and frequency converter Relationship between motion control and frequency converter

Motion control has a significant period characteristic, it is a combination of a variety of high-tech to push industrial automation, office automation and home automation to a higher stage. At present, the motion control is mainly composed of three parts: inverter, motor and controller. ...

The method of resetting the fault of the inverter The method of resetting the fault of the inverter

1. Power off the inverter and power it back on; 2. Press the FN button on BOP-2; 3. After the digital input 3, the default setting of 3 is reset to the problem; 4. Press the P button or power off, in the case of no problem; ...

Quickly locate switching power supply faults Quickly locate switching power supply faults

Switch Mode Power Supply (SMPS) will cause the base of the switch tube to fail to get the switching pulse and intermittently operate due to the short circuit of the load, the failure of the self-vibration circuit and the loss of control of the protection circuit, which makes it difficult to locate the shortcomings of SMPS. Difficult to repair the work ...

The wiring distance between the motor and the inverter The wiring distance between the motor and the inverter

Burn two new motors in a row! The output current and voltage of the inverter are balanced, the input voltage is balanced, the current is unstable, and the fluctuation is 20%-50%, the inverter is burned off by a short circuit between 35Hz turns, the grid voltage is very stable, 720V, the interval between the motor and the inverter is 120m, and the input and output terminals of the inverter are powered ...

Introduction to the use of PLC for power production Introduction to the use of PLC for power production

1. It is used for switching control The ability of PLC to manipulate switching quantities is very strong. The number of points in and out of the control, less than a dozen points, dozens of points, more can be hundreds, thousands, or even tens of thousands of points, because it can be networked, the number of points is almost unlimited, no matter how many points can be controlled, the control ...

Single-table driver for HLP2B Single-table driver for HLP2B

LS produces common sense of electroplastic case circuit breaker LS produces common sense of electroplastic case circuit breaker

Now in the process of using molded case circuit breakers, it is necessary to understand the rated current of molded case circuit breakers, and the rated current of molded case circuit breakers generally has more than a dozen, mainly 16A, 25 A, 30A, and the height may reach 630A. L ...

Next Page »
5678910111213Next
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top