The impact of inverters on motors – Delta inverters The impact of inverters on motors – Delta inverters

1. Overvoltage The output of the inverter has the function of voltage detection, and the inverter can actively adjust the output voltage so that the motor does not withstand overvoltage. Even when the output voltage adjustment fails and the output voltage exceeds 110% of the normal voltage, the inverter will be shut down and the motor will become infected. ...

Consider the timing of increasing the capacity of the inverter - Delta inverter Consider the timing of increasing the capacity of the inverter - Delta inverter

1. The rated current of the inverter is low As mentioned above, when the rated current of some inverters is less than the rated current of the motor of the same capacity, the inverter with a larger gear should be considered according to the load condition of the motor. 2. The motor may be overloaded for a short time Since the electric motor ...

Delta's active front-end inverter partner Delta's active front-end inverter partner

The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators. At this time, the inverter ...

Delta UPS power supply RT5K extension configuration method for 2 hours Delta UPS power supply RT5K extension configuration method for 2 hours

Engined DC: 1K=36V, 2K=72V, 3K=96V, 5K, 6K, 10K=192V UPS power supply accounting formula: 1KVA (volt-ampere) =700W (watt) =1000VA (volt) UPS power supply x extended time + starting DC = how big the battery is Start DC + V number of battery = how much power is distributed ...

Delta's inverter external positive and reverse operation mode Delta's inverter external positive and reverse operation mode

1. The external control panel is rotated and operated After selecting the upper or lower button on the panel, the Frd inverter will rotate forward if you select the inverter, and the rEu inverter will rotate 2. The external control terminal is rotated Access via external terminals ...

Synchronous control parameter setting method for two or more inverters - Delta Synchronous control parameter setting method for two or more inverters - Delta

Step 1 Two inverters, two wires, and one power supply. Step 2 The inverter wiring defines the two inverters as a master and a slave respectively, the host port 485A is connected to the slave port 485A, and the host port 485B is connected to the slave port 485B. ...

The gateway is connected to the Delta inverter The gateway is connected to the Delta inverter

This example is an example of the equipment used to connect a Modbubs to Profinet gateway to a Delta inverter, and the equipment used is a Siemens 1200 PLC, a Delta inverter, and a DJI Modbus to Profinet gateway. 1、Mo ...

The reason for the shaking of the inverter for the motor - Delta The reason for the shaking of the inverter for the motor - Delta

When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon? 1. The motor is damaged ...

The principle of Delta's inverter inverter The principle of Delta's inverter inverter

As far as I know, since the advent of active induction motors, there has been a variable frequency operation in the way of communicating generators. Change the rotational speed of the generator, and change its output frequency. Before the advent of high-speed transistors, this was one of the main ways to change the speed of the motor, but due to the decrease in the speed of the generator ...

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

Failure analysis of Delta inverter VFD-VL series Failure analysis of Delta inverter VFD-VL series

Fault 1: Overcurrent in acceleration Clarification: Overcurrent in acceleration Solution 1: Check whether the wiring from U-V-W to the motor is poorly insulated; 2: Increase acceleration and deceleration time; 3: Replace the inverter with a larger output capacity; 4: Reduced (P54) torque ...

Delta UPS uninterruptible power supply R-2K series Delta UPS uninterruptible power supply R-2K series

With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.

Use and maintenance of electric motors - Delta motors Use and maintenance of electric motors - Delta motors

The motor can be started after the work is completed before use, and attention should be paid to the investigation of the motor, transmission device, production machinery and line voltage and ammeter, if there is an abnormal phenomenon, it should be stopped immediately, the fault should be identified and swept away, and then it can be closed and started again. When the motor is running, ...

Excessive inverter capacity poses a hazard to electrical equipment – Delta Excessive inverter capacity poses a hazard to electrical equipment – Delta

(1) The harmonic current will directly cause the additional heating of the motor, so that the stator of the motor will exceed the rated temperature rise of the motor itself, so that the rated output capacity of the motor will be greatly reduced. ​ (2) The current wave output of the inverter ...

Factors affecting Delta's inverter motors and countermeasures Factors affecting Delta's inverter motors and countermeasures

1. The influence of leakage current on the motor and countermeasures If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...

Inverter power-on panel without display fault analysis - Delta Inverter power-on panel without display fault analysis - Delta

In the inverter problem, it is often encountered that the energized panel does not appear. Generally speaking, the problem of the inverter panel not showing up is usually caused by three parts, one is the poor contact of the contactor, the second is the control panel of the inverter, and the third is the damage of the power module that supplies power to the control panel.

The inverter needs to prepare the braking resistance condition - Delta The inverter needs to prepare the braking resistance condition - Delta

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to prevent the capacitor voltage from being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and prevent energy waste. However, the capacitance of the capacitor is ...

Inverter technology is a motor control method – Delta Inverter technology is a motor control method – Delta

When you are using the motor, if you simply change the frequency, your motor will most likely be burned out. This problem is especially acute when the frequency is reduced. In order to prevent the motor from burning out, the inverter must change the voltage at the same time as the frequency. ...

Detection methods for Delta circuit breakers, AC contactors and frequency converters Detection methods for Delta circuit breakers, AC contactors and frequency converters

1. Circuit breaker A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked. Under normal circumstances, when in the ON state, the input input ...

Delta inverter braking resistor selection Delta inverter braking resistor selection

1. The necessity of braking resistance If the regenerative energy that occurs during deceleration and descent in the application is too large, there is a possibility that the voltage of the main circuit inside the inverter will rise, causing damage. Due to the built-in overvoltage maintenance function in the inverter, the overvoltage of the main circuit (O ...

Delta's inverter process setting Delta's inverter process setting

1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...

Next Page »
CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top