NCH8G series household AC contactor (hereinafter referred to as contactor) is mainly suitable for AC 50Hz (or 60Hz), rated working voltage to 400V rated working current to 63A circuit, control household appliances and similar uses of low-inductance and micro-inductance loads; It can also be used to control the household motor load, and the control power should be reduced accordingly.
The products are used in homes, hotels, apartments and other places to realize automation functions and be used in large-scale production of household appliances.
Comply with standards: GB/T17885, IEC/EN 61095.
41 Classification according to the number of poles: contactors are divided into single-stage, two-pole and four-pole.
42. The rated insulation voltage, the agreed free air heating current, the use category and its corresponding rated working current and control power of the contactor
Rated insulation voltage: 500
Rated operating voltage: 400
Rated operating current: 63
This article introduces the product interest of CHINT/CHINT NCH8G Home AC Contactor NCH8G-63/22, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT CJ40 Series AC Contactor CJ40-63
CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.
|
|
CHINT/CHINT Motion Controller NSC1 Series Weight 102g
Introduction: NSC1 series motion controller has 2 communication ports, 1 RS232, 1 RS485; Two or four single-phase high-speed pulse counting, up to 200KHz respectively, one or two AB phase high-speed pulse counting, up to 200KHz; External real-time clock chip is used to make the clock more accurate; ...
|
|
CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-170
CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...
|
|
CHINT/CHINT Contactor NC11 Quota insulation voltage 690V
Introduction: CHINT/CHINT contactor NC11 is mainly used in the meter box to control the power supply system of the meter: under normal circumstances, the main contact of the contactor is kept on (that is, the main contact is normally closed at four poles, and one of the poles is used for the protection of the user's neutral line short circuit), only when the user owes ...
|
|
CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-400
DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...
|
|
CHINT/CHINT YBLX-WL Series Travel Switch YBLX-WL/CA12
YBLX-WL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program.
Accord with...
|
|
CHINT/CHINT CKJ5 Series Vacuum AC Contactor CKJ5-125
CKJ5 series vacuum AC contactor (hereinafter referred to as contactor) is mainly used in AC 50Hz, rated working voltage to 1140V, rated working current to 630A circuit, for long-distance connection and breaking of circuits, and can be used with appropriate thermal overload relay or electronic protection ...
|
|
CHINT/CHINT NM1B series plastic shell circuit breaker NM1B-160S
The circuit breaker is rated for insulation voltage up to 800V, suitable for AC 50Hz, rated working voltage up to 400V, rated working current from 10A to 250A in the distribution network circuit, used to distribute power and protect lines and power supply equipment from overload, short circuit, undervoltage and other faults. At the same time ...
|
|
CHINT/CHINT NH5-125 disconnector
NH5-125 disconnector is mainly suitable for AC 50Hz, rated voltage to 400V, rated current 125A and below in the power distribution and control circuit, mainly as the main switch in the terminal combination electrical appliances, can also be used for infrequent control of various low-power electrical appliances and lighting, widely used in industrial and mining ...
|
|
CHINT/CHINT AL-X3H alarm contact
The AL-X3H alarm contact conforms to GB/T 14048.5 standard. It is mainly used in lines with AC rated voltage to 415V or DC rated voltage to 130V, and assembled with NBH-125 series circuit breaker for signal indication of long-distance circuit breaker fault breaking.
Alarm contact is an accessory product, assembled in ...
|
|
CHINT/CHINT Circuit Breaker NBH-63 1P D4
NBH-63 miniature circuit breaker is suitable for AC 50Hz, rated voltage 230V/400V, rated current to 63A in the line, for overload and short circuit protection, under normal circumstances, as the line of infrequent operation and conversion of the use, can also be used as a disconnecting switch for disconnecting the line for line and equipment maintenance...
|
|
CHINT/CHINT NXBLE-63Y residual current action circuit breaker
CHINT/CHINT NXBLE-63Y residual current action circuit breaker
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated residual operating current (IOn): 0.01A, 0.03A, 0.05A, 0.075A, 0.1A, 0.3A;
Rated operating voltage (Ue): 2 ...
|
|
CHINT/CHINT HY23 Series Reverse Switch NF1 Load Type Switch
The NF1 load switch is suitable for electrical circuits with AC 50Hz or 60Hz and voltage 690V and below. It is widely used in power distribution systems and automation systems in construction, electric power, petrochemical and other industries. It is mainly used for the main switch of machine tools, fans and pumps, and can also be used as a small-capacity motor ...
|
|
CHINT/CHINT NB1G-63 miniature circuit breaker
NB1G-63 miniature circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working voltage 230V, rated current to 63A in the line, the line plays the role of overload short circuit and overvoltage protection, can also be used as the line infrequent operation conversion.
Standards: GB ...
|
|
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
CHINT/CHINT NXBLE-63 residual current operated circuit breaker
Rated current (In): 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A;
Rated residual operating current (I△n): 0.01A (1P+N, 2P), 0.03A, 0.05A, 0.075A, 0.1A, 0.3A (AC type); 0.03 ...
|
|
CHINT/CHINT NB7LE series residual current action circuit breaker
NB7LE series residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be ...
|
|
CHINT/CHINT AX-7 auxiliary contacts
AX-7 auxiliary contact is mainly used in the line of AC 50Hz, the agreed heating current to 3A, the AC rated voltage to 415V or the DC rated voltage to 125V, and is assembled with the NB7 miniature circuit breaker for the signal indication of the long-distance circuit breaker on/off.
Standards: GB/T 14048.5, IEC...
|
|
CHINT/CHINT CJX1-K Series Contactors The operating frequency is 1200 hours
Introduction: CJX1-K series AC vacuum contactor (hereinafter referred to as contactor), mainly used for AC 50Hz-60Hz, rated insulation voltage of 1000V, rated working voltage of 380V under the AC-3 use category of rated working current to 820A in the circuit, for long-distance connection and disconnection ...
|
|
CHINT/CHINT S9 shunt tripper
The S9 shunt trip device (hereinafter referred to as the tripper) is mainly used for matching with NB1 or NBH8 series circuit breakers, and is suitable for long-distance shunt tripping operation in lines with AC 50Hz (or 60Hz) rated voltage to 400V.
Meets the standard: IEC60947-5-1, obtained CE certification.
3.1 Basic ...
|
|
CHINT/CHINT NXC Series AC Contactor NXC-06M
The new NXC series of AC contactors is an innovative and compact design. It is mainly used to start and control AC motors frequently, turn on and break circuits at long distances, and can form electromagnetic starters with appropriate thermal overload relays.
●Conform to the standard: GB/T 14048.1/IEC 6094 ...
|
|