    Product Introduction
    NB7LE series residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, four poles, four poles 400V, rated current to 63A lines
Product Description
NB7LE series residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can quickly cut off the fault power supply in a very short time, protect the safety of people and electrical equipment, and can also be used as the overload and short circuit protection of the line. and infrequent switching on and off electrical installations and lighting circuits under normal circumstances, especially suitable for industrial and commercial lighting power distribution systems.
CHINT/CHINT NB7LE series residual current action circuit breaker

Comply with standards: GB/T 16917.1, IEC61009-1, and obtain CCC and other certifications.

Rated voltage (Ue)230V AC(1P+N、2P)、 400V AC(3P、3P+N、 4P) .
Rated current (In)The shell level current of 32A is: 6A, 10A, 16A, 20A, 25A, 32A
The shell level current of 63A is: 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A
Rated insulation voltage (Ui)500V
Rated impulse withstand voltage (Uimp)4kV
Rated residual operating current(△N)0.03A、0.1A、 0.3A
Rated residual non-operating current (I△no)0.51An
Number of poles1P+N、2P、3P、3P+N、4P
Instantaneous trip typeType C, Type D
Rated short-circuit breaking capacity Icn)6000A(C6 ~ C40)、4500A(C50、 C63、 D6 ~ D63)
Rated residual on-off and breaking capacity (I△m)2kA
This article introduces CHINT/CHINT NB7LE series residual current action circuit breaker If you are interested, please also contact our customer service, we are looking forward to your call, and hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
More on that
CHINT/CHINT Miniature Circuit Breaker NXB-63H has a frequency of 50Hz CHINT/CHINT Miniature Circuit Breaker NXB-63H has a frequency of 50Hz

Introduction: CHINT/CHINT miniature circuit breaker NXB-63H is a new type of leakage circuit breaker integrating leakage relay, leakage circuit breaker, AC contactor, undervoltage and other functions. It can automatically distinguish between slowly variable leakage and abrupt leakage (electric shock) for protection Product parameters Forehead...

CHINT/CHINT NA1 series universal circuit breaker CHINT/CHINT NA1 series universal circuit breaker

NA1 series universal circuit breaker (hereinafter referred to as circuit breaker) is suitable for AC 50Hz, rated working voltage to AC690V, rated working current to 6300A and below in the distribution network, used to distribute electric energy and protect lines and power equipment from overload, undervoltage, short circuit, single-phase grounding, etc.

CHINT/CHINT AX-6 auxiliary contacts CHINT/CHINT AX-6 auxiliary contacts

AX-6 auxiliary contact is mainly used in AC 50Hz, rated heating current to 6A, rated voltage to 415V or DC rated voltage to 130V line, which is assembled with NB1 series circuit breaker for signal indication of long-distance circuit breaker on/off. Standards: GB/T 14048.5, IEC 6094 ...

CHINT/CHINT CJ40 Series AC Contactor CJ40-160 CHINT/CHINT CJ40 Series AC Contactor CJ40-160

CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT NXBF-63 miniature circuit breaker CHINT/CHINT NXBF-63 miniature circuit breaker

NXBF-63 miniature circuit breaker is mainly used for overload and short circuit protection of power lines in household and similar places with AC 50Hz, rated voltage to 230/400V and rated current to 63A, and can also be used to turn on and off electrical devices and power lines infrequently under normal circumstances. ...

CHINT/CHINT NB1L-63 residual current action circuit breaker CHINT/CHINT NB1L-63 residual current action circuit breaker

NB1L-63 residual current action circuit breaker is suitable for AC 50Hz, rated voltage single pole two wires, two poles 230V, three poles, three poles four wires, four poles 400V, rated current to 63A in the line, when the person is electrocuted or the leakage current of the power grid exceeds the specified value, the residual current action circuit breaker can be used in the pole ...

CHINT/CHINT NXC series AC contactors CHINT/CHINT NXC series AC contactors

The new NXC series AC contactor has a novel appearance and compact structure. It is mainly used to start and control AC motors frequently, turn on and break circuits at long distances, and can form electromagnetic starters with appropriate thermal overload relays. Standards: GB/T 14048.1/IEC 60947-1, ...

CHINT/CHINT CJ40 Series AC Contactor CJ40-315 CHINT/CHINT CJ40 Series AC Contactor CJ40-315

CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT Terminal Appliance —NXHB-125 Disconnector CHINT/CHINT Terminal Appliance —NXHB-125 Disconnector

The NXHB-125 disconnector complies with IEC60898 and GB10963 standards. It is suitable for AC 50Hz or 60Hz, rated voltage 250V and below residential single-phase lines, to protect the overload and short circuit of electrical lines. The product has high breaking capacity, small size and a width of only 18mm. Zero, fire ...

CHINT/CHINT CKJ11 series AC vacuum contactor CHINT/CHINT CKJ11 series AC vacuum contactor

CKJ11 series AC vacuum contactor (hereinafter referred to as contactor) is mainly used in photovoltaic and wind power industries for long-distance connection and breaking circuits, and can also be used in mining, smelting, textile, construction and other places to remotely connect and break and frequently start to control AC motors. Accord with...

CHINT/CHINT Terminal Appliance —NH3-63 Disconnector CHINT/CHINT Terminal Appliance —NH3-63 Disconnector

NH3-63 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage 230V, rated current to 63A resistance circuit, mainly for no load to turn on or off the circuit, for the line and power supply to be connected or isolated. It is especially suitable for effective isolation of power supply during line maintenance ...

CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-150 CHINT/CHINT CJ19 Series Switching Capacitor Contactor CJ19-150

CJ19 series switching capacitor contactor (hereinafter referred to as contactor) is mainly used in power lines with AC 50Hz (or 60Hz) and rated working voltage to 690V, which is used for low-voltage reactive power compensation equipment to put in or remove low-voltage shunt capacitors. Contactors with inhibition ...

CHINT/CHINT CJ40 series AC contactors CHINT/CHINT CJ40 series AC contactors

● CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching on and off circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT XF9J alarm auxiliary contact CHINT/CHINT XF9J alarm auxiliary contact

XF9J alarm auxiliary contact is suitable for the line with the agreed heating current to 6A, AC rated voltage to 415V or DC rated voltage to 130V, and it is assembled with NB1 miniature circuit breaker or NB1L residual current action circuit breaker for signal indication of long-distance circuit breaker on/off. Compliant with standards ...

CHINT/CHINT NB8LE-63M residual current action circuit breaker CHINT/CHINT NB8LE-63M residual current action circuit breaker

NB8LE-63M residual current action circuit breaker is mainly suitable for AC 50Hz, rated voltage of 230V, rated current to 63A in commercial office buildings, residential and general industrial terminal distribution lines, to provide overload, short circuit protection and leakage protection for the line, but also under normal circumstances...

CHINT/CHINT AL-X1H alarm contact CHINT/CHINT AL-X1H alarm contact

AL-X1H alarm contact is mainly used in the line with AC rated voltage to 415V or DC rated voltage to 130V, and is assembled with NBH-40 and NBH-63 series circuit breakers for signal indication of remote circuit breaker fault breaking. The alarm contact is an accessory product that is assembled on the left side of the circuit breaker for use.

CHINT/CHINT CJX1-K series AC vacuum contactor CHINT/CHINT CJX1-K series AC vacuum contactor

CJX1-K series AC vacuum contactor (hereinafter referred to as contactor), mainly used for AC 50Hz-60Hz, rated insulation voltage of 1000V, rated working current to 820A under the AC-3 use category of rated working voltage of 380V, for long-distance connection and breaking of the circuit ...

CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250 CHINT/CHINT DZ20 Series Plastic Case Circuit Breaker DZ20Y-1250

DZ20 series plastic shell circuit breaker (hereinafter referred to as circuit breaker), its rated insulation voltage is 660V, AC 50Hz, rated working voltage 380V and below, and its rated current is from 32A to 1250A. Generally used for power distribution, the rated current of type C is 160A and below, and the shell of type 630 and below ...

CHINT/CHINT NBHLE-63Y residual current action circuit breaker CHINT/CHINT NBHLE-63Y residual current action circuit breaker

NBHLE-63Y residual current action circuit breaker is suitable for AC 50Hz, rated voltage 230V, rated current to 63A line, play the role of overload, short circuit and leakage protection, can also be used as infrequent line on/off under normal circumstances. The product conforms to IEC61009-1, GB/T 1691 ...

CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5000 CHINT/CHINT YBLX-HL series travel switch YBLX-HL/5000

YBLX-HL travel switch is mainly used in the control circuit of AC 50Hz or 60Hz, voltage 380V, DC voltage 220V, for the travel control of the moving mechanism, the transformation of the direction or speed of the movement, the automatic control of the machine tool, the limit action of the moving mechanism and the control of the stroke or program. Comply with the standard ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top