1. The capacitance is generally indicated by "C" plus a number in the circuit (e.g., C25 indicates the capacitance numbered 25).
A capacitor is an element composed of two metal films that are placed next to each other and separated by an insulating material. The characteristic of the capacitor is first and foremost the communication through the DC block. The capacitance capacity is the size of the capacitor that can store electrical energy, and the blocking effect of the capacitor on the communication signal is called capacitive reactance, which is related to the frequency and capacitance of the communication signal.
Capacitive reactance XC=1/2πf c (f indicates the frequency of the communication signal, C indicates the capacitance capacity)
2. Capacitance identification method
The identification method of capacitance is basically the same as that of resistor, and there are three types: direct standard method, color mark method and number mark method. The basic unit of capacitance is indicated by farad (F), and other units are: millimethod (mF), micromethod (uF), nanomethod (nF), picomethod (pF).
In between: 1 farad = 103 millifa = 106 microfa = 109 nanofa = 1012 picofar
Capacitors with large capacitances have capacitance values that are indicated directly on the capacitor, e.g. 10 uF/16V
A capacitor with a small capacitance has a capacitance value indicated by a letter on the capacitance or a number indicating 6
Letter indication method: 1m = 1000 uF 1P2 = 1.2PF 1n = 1000PF
Numerical indication: Generally, three digits are used to indicate the size of the capacity, the first two digits indicate significant figures, and the third digit is the magnification.
For example, 102 indicates 10×102PF=1000PF 224 indicates 22×104PF=0.22 uF
3. Capacitance capacity error table
Symbol F G J K L M
Allowable Error ±1% ±2% ±5% ±10% ±15% ±20%
For example, if the capacitance of a ceramic tile is 104J, the capacitance is 0. 1 uF, error of ±5%.
4. Fault characteristics
In the actual maintenance, the main problems of the capacitor are: (1) The open circuit fault caused by pin corrosion.
(2) Open circuit defects of desoldering and virtual welding. (3) After leakage, the volume is small or the open circuit is formed.
(4) Leakage, serious leakage and breakdown problems.
|
More on that
|
Is a circuit breaker an air switch? - Delixi
1. Circuit breaker refers to a switchgear that can turn on, carry and turn off the current under normal circuit conditions and turn on, carry and turn off the current under abnormal circuit conditions within a regular time.
According to the voltage of Delixi circuit breaker, there are high-voltage circuit breakers and low-voltage circuit breakers. Below 1kV ...
|
|
Delixi inverter all aspects of the selection of precautions
The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...
|
|
The principle of circuit breaker jumping, closing and holding circuit - Delixi
During opening and closing operations, the remote opening and closing command is usually a high-level pulse of several hundred milliseconds. In order to prevent the pulse from becoming invalid before the end of the opening and closing operation, and to ensure that the opening and closing operation is completed, a holding circuit is added. Intuitively, it is to avoid tripping and closing, and the exit contact precedes the DL ...
|
|
Delixi circuit breaker tripper selection and tuning analysis
Among the objects of circuit breaker maintenance, there are some electrical equipment that generate several times its rated current in a short period of time during the start-up process
(1) The setting of the operating current of the instantaneous overcurrent tripper
In the circuit breaker maintenance of ...
|
|
A brief introduction to the characteristics of Delixi
1. Nominal value
A suitable approximation of a switchgear or component and equipment to mark or identify it.
2. Limiting value
The maximum or minimum promise of a quantity in the specification and specification.
3、 ...
|
|
Causes and solutions for circuit breaker closing failure - Delixi circuit breaker
1. Failure analysis.
1) Closing fuse, control fuse blowing or poor contact.
2) Poor contact of DC contactor or poor contact of control switch contact and auxiliary contact of circuit breaker.
3) The DC voltage is too low.
4) Closing and locking action.
...
|
|
The difference between Delixi air switch and leakage protection switch
1. The role is different
The air switch is a kind of circuit breaker that protects the "object", which can protect the safety of the entire household wiring and electrical appliances and other items to prevent the wire from being burned due to overheating.
The leakage protection switch is a kind of circuit breaker that protects "people", which can be cut in time when leakage.
|
|
Delixi voltage regulator boot voltmeter does not indicate fault analysis and solutions
When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem phenomenon and cause analysis
1. The plug is not plugged in firmly, and there is no output voltage
2. The fuse is broken
When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem is solved ...
|
|
Precautions for leakage vacuum circuit breaker circuit - Delixi
Leakage vacuum circuit breaker connection: When normal operation, regardless of whether the three-phase load is balanced or not, the sum of the three-phase current phasor through the main circuit of the zero-sequence current transformer is equal to zero, so there is no induced electromotive force in the secondary winding, and the leakage maintainer operates in a closed state. In the event of leakage or ...
|
|
Delixi air switch object, structure, principle
Application of air switches (circuit breakers).
Delixi air switch, also known as circuit breaker. It is a switch that actively closes as soon as the current in the circuit exceeds the additional current. Air switch is a very important electrical appliance in the low-voltage distribution network and electric traction system.
|
|
Delixi time control switch KGL1 latitude and longitude technical parameters
Delixi Electric KGL1 latitude and longitude time control switch is suitable for communication 50Hz operating voltage 380V and the following control circuits, Delixi time control switch, according to the local latitude and longitude, according to the season to change the automatic adjustment control time, as the timing of the implementation of components. Plugging in or out of all sorts of ...
|
|
Delixi leakage circuit breaker identification method
1. Appearance
Genuine Delixi switch shape is more fashionable, looks elegant and beautiful, and the surface is neat, impact resistance is relatively strong, will not briefly crack or yellow.
And most imitations will turn yellow after a period of use...
|
|
Delixi three-phase motor electrical control circuit principle
What is the principle of the electrical control circuit of the three-phase motor? First of all, let's take a look at what is the principle of electrical control of work machinery. The schematic diagram of the electrical control circuit of the working machinery is actually connected with graphic symbols, text symbols and lines to show the connection relationship and circuit of each electrical component.
|
|
Product features of Delixi equalizer
1. The divider is the sixth generation of intelligent machine using microcomputer chips, and the intelligent program is very high.
2. Single-phase three-phase connection, the divider on the market is scored as A, B, and C three-phase wiring for three-phase electricity, which is not only inconvenient for installation, but also prone to phase sequence errors.
3. Can ...
|
|
Delixi inverter parameter setting method
P0.00: Set to G type (constant torque load type).
P0.01: Set to 1 fundamental efficacy model.
P0.02: Set to 1V/F control.
P0.03: Set to 0 keyboard control.
P0.04: Set to be given by the external terminal for multi-segment commands.
...
|
|
Whether the inverter can be debugged without load - Delixi
1. First carry out the no-load test operation of the inverter
First of all, check whether all the wiring of the inverter is correct, do not connect the output of the inverter to the motor, and conduct a no-load test on the inverter first. Read the user manual of the inverter carefully before powering on to understand the relevant functions and settings, and operate ...
|
|
Delixi inverter uses the keyboard to set the frequency step
Delixi inverter parameter check setting steps
Using the keyboard to set the frequency, we can use the keyboard number direct setting and the keyboard potentiometer setting two methods, and the control method can be selected by modifying the parameter P0.01.
...
|
|
Delixi linear regulator and switching regulator maintenance
Whether it is a linear regulator or a switching regulator, their daily protection must start from the following aspects:
1. Always observe whether the cooling fan and transmission organization of the voltage regulator are operating normally, check whether the input voltage and load exceed the rated scale, and deal with the abnormalities in time.
|
|
Thermal calculation of linear regulator - Delixi
Thermal accounting requires information such as power loss, thermal resistance of the package, and ambient temperature. The power loss is calculated in the same way as the efficiency accounting, which is simply the value of the difference between the output input voltage and the input current. The thermal resistance should have a technical standard documented, and if it is not, it is necessary to ask the manufacturer. Basically...
|
|
Delixi launched a new 6 series CDW6i frame circuit breaker
At the end of July, Delixi Electric launched a new 6 series CDW6i structural circuit breaker and a number of industrial control accessories.
The new 6 series CDW6i structural circuit breaker has complete product specifications, which can provide professional customers with more choices, excellent functions, and ...
|
|