Among the objects of circuit breaker maintenance, there are some electrical equipment that generate several times its rated current in a short period of time during the start-up process
(1) The setting of the operating current of the instantaneous overcurrent tripper
Among the objects of circuit breaker maintenance, there are some electrical equipment that will generate several times the current of its rated current in a short period of time during the start-up process, so that the circuit breaker will bear a large peak current in a short period of time. The operating current lop(o) of the transient overcurrent tripper must avoid the peak current Ipk of the line, i.e. IOP(o) ≥ krel ipk. In the meantime, Krel is the reliability factor. When selecting a circuit breaker, attention should be paid to making the setting current of the instantaneous overcurrent tripper of the circuit breaker avoid the peak current, so as to avoid the malfunction of the circuit breaker.
(2) The setting of the operating current and operating time of the short-delay overcurrent tripper
The operating current lop(s) of the short-time overcurrent tripper should also avoid the peak current of the line, Ipk, i.e., IOP(s) ≥ krel ipk. In the meantime, Krel is the reliability factor. The action time of short-term overcurrent tripping equipment is generally divided into three types: 0.2s, 0.4s and 0.6s, which are confirmed according to the maintenance selectivity of the front and rear maintenance equipment, so that the action time of the previous maintenance is one time difference longer than the action time of the latter maintenance.
(3) The setting of the action current and action time of the long-delay overcurrent tripper
The long-delay overcurrent tripper is mainly used for overload maintenance, so its operating current Iop (l) only needs to avoid the maximum load current of the line, that is, the accounting current I30, that is, IOP (L) ≥ Krel I30. In the meantime, Krel is the reliability factor. The action moment of the long-term overcurrent tripper should avoid the promised short-term overload duration time to avoid the malfunction of the low-voltage circuit breaker.
(4) The requirements for the operation current of the overcurrent tripper and the line to be maintained
In order to avoid overheating, damage and even fire of the insulated cable due to overload or short circuit, the circuit breaker does not trip, and the action current of the circuit breaker overcurrent tripper should meet the requirements of the formula, lop ≤ Kol Ial. In the meantime, Ial is the promised ampacity of the insulated cable; Kol is the promised short-time overload coefficient of the insulated cable, which is generally 4.5 for instantaneous and short-delay overcurrent trippers, and 1.1 for short-circuit maintenance and 1 for load maintenance only. If the above matching requirements are not met, the tripping action current should be changed, or the cross-sectional area of the conductor or cable should be appropriately increased.
|
More on that
|
Delixi circuit breaker product characteristics classification
The function of Delixi circuit breaker is to make the circuit breaker internal electromagnetic tripping when the electrical equipment produces short circuit, overload, etc., resulting in the circuit breaker disconnecting the power supply, and maintaining the safety of electrical equipment and personnel.
When the electrical equipment is running, the circuit may produce abnormalities, which is the demand circuit breaker in the ...
|
|
Technical parameters of surge protective device - Delixi
Look at the quality of the surge protector, to see whether it can complete the fundamental specification for him, the primary specification related to the surge protector is whether the surge operating voltage can be limited to the required value below, the surge protector in the completion of this mission when it is necessary to discharge the lightning current, this specification is necessary to completely ...
|
|
Delixi Electric universal switching power supply
Delixi general switching power supply can provide stable DC output products, widely used in communications, LED displays, industrial control, radio and television, computer networks, medical equipment, intelligent monitoring and other fields.
Delixi universal switching power supply SA, DA, TA, QA Type 85 - 132 / ...
|
|
Delixi relay maintenance method
Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.
|
|
The reason for the unstable pressure of Delixi inverter system
Problem Description:
The pressure of Delixi inverter system is unstable, simple vibration?
Solution(s):
The pressure of the system is unstable, which can be due to the following reasons:
A. The position of the pressure sensor to collect the pressure of the system is ...
|
|
Delixi spare parts replacement cycle
1. Cooling fan (2-3 years)
As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.
|
|
The basic knowledge of Delixi switching regulators
1. What is a switching regulator?
Switching regulator, English (regulatior), some people call it a regulator, a voltage regulator source. To achieve voltage regulation, it is the demand control system (negative feedback), from the automatic control theory, we know that when the voltage rises through negative feedback to reduce it, ...
|
|
Delixi inverter controller output problem analysis
The output of Delixi inverter controller does not match the operating frequency, and the analog output of the inverter is abnormal?
Solution:
First, you should confirm what hardware is wrong. Make the controller enter the manual debugging state, and use the universal ...
|
|
Delixi inverter fault maintenance
Delixi inverter is a commonly used inverter, how to maintain in the event of failure?
Constant speed overcurrent: When the inverter is running at a constant speed, the output current exceeds the current value.
Check whether the output circuit of the inverter is short-circuited.
Check if the input voltage is low.
Examine...
|
|
Type of use of AC regulated power supply
(1) Ferromagnetic resonant communication regulator: a communication regulator composed of a full choke and a corresponding capacitor, with constant voltage voltammetry characteristics. The full type is a typical structure in the early stage of this type of regulator. It has simple structure, convenient production, wide allowable scale of input voltage, reliable operation, and overload energy.
|
|
Delixi won the lawsuit "Delixi United" to defend its rights by legal means
On July 14, the official Weibo of the Beijing Municipal Patent People's Court "Intellectual Property Beijing" released information that Delixi Group Co., Ltd. (hereinafter referred to as "Delixi Group") sued the former administrative department of China's State Administration for Industry and Commerce to dispute the proposal has been adjudicated in the first instance not long ago, and the appellant Delixi ...
|
|
The reason for the failure of the inverter - Delixi
1. Ability to adapt to the environment
When the motor on the bus starts in a group, when the bus is the largest motor unit starts, the impact on the operation of the inverter, which is related to the input voltage fluctuation scale parameters promised by the inverter, for thermal power units should ensure that the bus voltage drops by 30% when the frequency conversion ...
|
|
Delixi control transformer structure type
Delixi's control transformer is one of the products used in many equipment, the type of Delixi transformer is divided into: BK, JBK, BKC, JMB, BJZ, DG, BZ and other series of control lighting transformers, with excellent performance, reliable work, wide applicability and other characteristics, generally used in machine tools, mechanical ...
|
|
Delixi's AC contactor selection
It is selected according to the type of load current in the circuit. AC loads should be selected AC contactors, DC loads should be DC contactors, assuming that the control system is mainly AC loads, DC motors or DC loads have a small capacity, AC contactors can also be used to control, but the contact of the ...
|
|
Why is the operation of the inverter energy-efficient? - Delixi
The inverter lowers the output frequency to reduce the speed of the motor, taking the conditioning air volume as an example. By reducing the air volume, power consumption can be significantly reduced. Why is the operation of the inverter energy-efficient?
According to fluid mechanics, power = pressure× flow, flow ...
|
|
The difference between linear regulator and switching regulator - Delixi
The switching voltage regulator is a different kind of regulated power supply from the linear voltage regulator, and its circuit types mainly include single-ended flyback, single-ended forward, half-bridge, push-pull and full-bridge.
The difference between it and the linear power supply is that the transformer in the circuit does not work at the power frequency, but at the power frequency.
|
|
Inverter maintenance technology - Delixi inverter
(1) Fault characteristics
a) *** tripping may occur during operation, but if it is restarted after resetting, it often trips as soon as the speed rises.
b) has a large inrush current, but most drives can already be tripped, maintenance without damage. Due to the ...
|
|
Delixi inverter alarm parameter check method
1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...
|
|
Delixi general inverter E100 series products introduction
E100 series products are a standard inverter with optimized open-loop vector control, V/F control, stable performance, rich functions, optimized structural design, exquisite appearance, and high cost performance.
Technical features:
...
|
|
Judgment and treatment of inverter short-circuit fault characteristics - Delixi
(1) Fault characteristics
a) The first trip may occur during operation, but if it is restarted after resetting, it will often trip as soon as the speed is raised.
b) have a large inrush current, but most drives are now able to perform maintenance trips without damage. Due to the ...
|
|