Delixi inverter uses the keyboard to set the frequency step

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi inverter parameter check setting steps

Using the keyboard to set the frequency, we can use the keyboard number direct setting and the keyboard potentiometer setting two methods, and the control method can be selected by modifying the parameter P0.01.

                                  Delixi inverter uses the keyboard to set the frequency step

1. Use the numeric keypad to set the frequency directly

A. The value of the primary setting parameter P0.01 is 1.

B. When the inverter is running, you can press 4 and 7 keys to enter the frequency setting method; This moment manifests for example.

C. Press the 4 button again to adjust to the desired set frequency, such as 48.00Hz, which will appear at this moment.

D. The adjusted set frequency will be automatically stored in the parameter P0.02.

E. Press the MODE button to return to the parameter setting method, and then press the MODE button to return to the operation monitoring method, which is displayed at this moment.

F. The frequency setting value can only be changed by numeric keypad during operation.

2. Use the keyboard potentiometer to set the frequency

The first parameter P0.01 is set to a value of 0, and then the user can rotate the potentiometer knob on the keyboard left and right to adjust the desired set frequency, and the frequency setting value will not be automatically stored in the parameter P0.02.
More on that
Delixi frequency converter E series precautions Delixi frequency converter E series precautions

1. Before the inverter device is in place and debugged, please tighten the components, especially the connecting bolts of the wire part, if not tightened, the connection will be heated and cause fire. 2. The on-site planning of the installation should be reasonable, and the excellent ventilation environment should be maintained. 3. The incoming and outgoing power lines of the inverter are not ...

Delixi E180 universal inverter introduction Delixi E180 universal inverter introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...

Delixi voltage regulator in the case of no load stable work? Delixi voltage regulator in the case of no load stable work?

Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...

Introduction to the type classification of voltage regulators - Delixi Introduction to the type classification of voltage regulators - Delixi

Voltage regulators have become an integral part of many appliances in household, industrial, and commercial systems. Earlier, manually operated or switchable regulators were used to raise or lower the input voltage to supply the output voltage within the desired range. This stabilizer is built with electromechanical relays as switchgear ...

Inverter plus output reactor - Delixi Inverter plus output reactor - Delixi

input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the performance and service life of the inverter and the motor, so it is necessary to install a transmission in front of it.

Fault analysis of commonly used voltage electrical appliances - Delixi Fault analysis of commonly used voltage electrical appliances - Delixi

1. Voltage circuit breaker problem The contact is overheated, you can smell the power distribution control cabinet, by checking that the moving contact is not completely inserted into the static contact, and the contact pressure is not enough, resulting in a decrease in the switching capacity, causing the contact to overheat. At this moment, it is necessary to adjust the operating organization so that the moving contact is completely inserted into the static contact ...

Delixi time control switch how to adjust the control time Delixi time control switch how to adjust the control time

1. Check the time first, if the time of the week, hour and minute is correct, don't care. If it's not correct, you need to take care of it yourself. Conditioning is very simple, you just need to press the clock, and then adjust the week by week, the hour of conditioning, and the minutes of conditioning. ...

Delixi air switch object, structure, principle Delixi air switch object, structure, principle

Application of air switches (circuit breakers). Delixi air switch, also known as circuit breaker. It is a switch that actively closes as soon as the current in the circuit exceeds the additional current. Air switch is a very important electrical appliance in the low-voltage distribution network and electric traction system.

The cause of the failure of Delixi inverter The cause of the failure of Delixi inverter

1. Overcurrent (short circuit) Overcurrent problems are the most common in the side of various faults in the inverter. The problem is mostly due to the following problems: first, as long as the speed converter is reported when starting, it is clear that the overcurrent is very serious, and most of them are load short circuits, mechanical parts stuck, inverters...

Analysis of the reasons why the maintenance of Delixi frame air switch can not be closed Analysis of the reasons why the maintenance of Delixi frame air switch can not be closed

The low-voltage air circuit breaker is the primary equipment for low-voltage power distribution, and it should be able to operate reliably when the electrical equipment is no-load, load-loaded or short-circuited. Its primary function is to maintain the line and equipment, can turn on, carry and break the current under normal circuit conditions, and can also be used in the specified non-...

Delixi anti-leakage is different from ordinary circuit breakers Delixi anti-leakage is different from ordinary circuit breakers

Circuit breaker refers to a switchgear that can close, carry and break the current under normal circuit conditions, and can close, carry and break the current under abnormal circuit conditions within a specified time. Circuit breakers can be used to distribute electrical energy, infrequently start asynchronous motors, and ...

Delixi small contactor structure introduction Delixi small contactor structure introduction

Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking. ...

The treatment method of leakage protector often tripping - Delixi The treatment method of leakage protector often tripping - Delixi

1. Trial delivery and commissioning method The first thing to find is the fault of the remaining current action maintainer itself. The detailed operation method is: first block the power supply, and then remove all the zero-sequence transformer load side leads of the remaining current action maintainer (the second and third level remaining current action maintainers will directly remove the outgoing ...

Instrumentation overhaul method - Delixi Instrumentation overhaul method - Delixi

Contrasting method The specific method is to let the problematic meter and the normal meter operate under the same conditions, and then detect the signals at some points and compare the two sets of signals measured, if there are differences, you can conclude that the fault is here. This method requires maintenance personnel to have considerable knowledge and skills.

The reason for the instability of the voltage regulator output - Delixi The reason for the instability of the voltage regulator output - Delixi

It shows that the voltage regulator base is not voltage corrected, and the voltage regulator in this situation is like a transformer, the higher the input voltage, the higher the output voltage, the input decreases and the output voltage also decreases. This...

Introduction of low dropout linear regulator - Delixi Introduction of low dropout linear regulator - Delixi

LDO, or low dropout regulator, is a low-dropout linear regulator that uses a transistor or field-effect transistor (FET) operating in its saturation region to subtract the excess voltage from the input voltage used to generate a conditioned output voltage. ...

Delixi inverter usage Delixi inverter usage

First of all, Delixi inverter has a very high control accuracy. It uses advanced electronic skills and digital control skills, and can control the speed, torque, and current of the motor with a high degree of control. Together, the controller of Delixi inverter also has a high overload capacity and strong ...

Regularly inspect the inverter steps and methods - Delixi Regularly inspect the inverter steps and methods - Delixi

When the VFD is viewed regularly, the power supply should be blocked, the operation of the VFD should be stopped, and the cover of the VFD should be removed. The first thing is to check the places that cannot be seen without downtime, or the places where it is difficult to find problems on a daily basis, as well as the inspection and adjustment of electrical characteristics. After blocking the VFD power supply, the main power ...

Delixi inverter alarm parameter check method Delixi inverter alarm parameter check method

1. There is a problem with a frequency converter, it cannot operate and the LED shows "UV" (abbreviation of under voltage), which clarifies that the alarm in the book is DC bus undervoltage. Since the control loop power supply of this type of inverter is not taken from the DC bus, but from the communication input through the transformer alone...

How to solve the data running flight of Delixi inverter controller How to solve the data running flight of Delixi inverter controller

Problem depiction: Delixi inverter controller data flying, or the data is occasionally incorrect, how to solve? Solution(s): This is the result of severe disturbances to the controller. Frequently...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top