ASCO Series 588 manifolds will reduce engineering and installation timelines for manufacturers, improving energy efficiency, product life and equipment reliability
Florham Park, NJ (July 19, 2023) — Emerson has released the ASCO™ Series 588 benchtop oxygen concentrator manifold, the healthcare industry's first turnkey manifold solution that optimizes the planning of respiratory therapy equipment and accelerates new product time-to-market. For patients who rely on oxygen concentrators, it is important to use them quickly, so it is important that the oxygen concentrators are ready to use and operate stably. The Series 588 manifold has been specifically planned to simplify the engineering planning and installation of your equipment, improving your energy efficiency, service life and reliability.
If there is no manifold integration solution, the manufacturer has to install the valves one by one into the air circuit of the oxygen concentrator and use special pipes to connect each port. The lightweight 588 Series manifold easily integrates the oxygen concentrator's fluid pathway, significantly reducing engineering planning and installation time for medical device manufacturers. The 588 Series features two rugged, universal valves that provide precise control of the air flow between the compressor and the molecular sieve. Manifolds can be easily fixed to the fluid path, and barb port planning simplifies piping connection.
"Oxygen concentrators are important for patients with chronic respiratory diseases, so they need to be ready for treatment. However, the most important thing for this type of equipment is how to plan the fluid path properly, which requires a lot of time. "Our fluid path experts have planned a low-power, yet stable solution in the ASCO Series 588 manifold, saving medical manufacturers time and operating costs." Manufacturers only need to connect a few pipes, making installation quick and easy. ”
In addition to simplifying planning and installation, the 588 Series improves equipment efficiency and reliability, and extends product life. The manifold is compact, so we don't have to sacrifice performance to make the device more compact. The valve's low power consumption extends the device's battery life and time between charges, setting the manufacturer's products apart from the competition. The high reliability of the valve extends the overall service life of the oxygen generator and reduces the operating cost of the manufacturer.
|
More on that
|
Fisher Series 67 Direct Acting Regulator Features:
Fisher Series 67 Direct Acting Regulator Features:
Compact structure - 67C series regulators have outstanding performance in redesign, compact structure and light weight;
Panel Mount - The panel mount structure consists of a handwheel adjustment screw equipped with another 1/4NPT vent, spring box and mounting ...
|
|
Fisher Fisher – filters, pressure reducing valves, lubricators
The filter, pressure reducing valve and lubricator together form a pneumatic triplet. The filter is mainly responsible for filtering liquid water, oil and impurities in the compressed air, the pressure reducing valve is mainly responsible for controlling the system pressure, and the lubricator is responsible for the oil lubrication of the back-end components. In general, the lubricator is not used much, because ...
|
|
United States Fisher pneumatic valve positioner fault repair and protection methods
United States Fisher Pneumatic Valve Positioner is the primary accessory to the Pneumatic Control Valve, which is a single-output valve positioner. It describes the main features and common faults of the valve positioner, as well as the treatment methods and protection methods.
1. The main features of the locator
(1) Large-diameter pilot ...
|
|
Fisher Fisher - Why do control valves vibrate? Cause analysis
The vibration of the control valve is generally divided into two states, one is the overall vibration of the control valve, that is, the entire control valve frequently vibrates on the pipeline or base. The other is the vibration of the spool of the regulating valve, which can be seen from the frequent movement of the valve stem up and down, and the following are the causes of these two vibrations and their treatment
Measure...
|
|
Fisher Fisher – Overcoming the difficulty of selecting control valve trims
Rules of thumb for flow characterization selection
Different applications favor different valve flow characteristics. These rules of thumb do not cover all situations, but they can address many of the typical situations encountered in the process industry.
Linear control valves are often chosen for pressure control, including near-constant ...
|
|
Fisher Fisher - The current development status of fluorine-lined ball valves in China
With the investment in infrastructure in developing countries, many industries and fields are quietly undergoing major changes, such as pipeline industry, petroleum, chemical industry, so the role of valves in the industry is also reflected.
At present, fluorine-lined ball valves have been ...
|
|
Fisher Fisher - Five Essentials for Valve Installation
Emerson's Fisher Fisher valve installation five key points:
First, direction.
Many valves are directional.
Such as globe valves, throttle valves, pressure reducing valves, check valves, etc. , if installed in reverse, it will ...
|
|
Fisher introduces a digital valve controller
Emerson Fisher Fisher introduces the Fisher FIELDVUE DVC6200 Digital Valve Controller with Stainless Steel Housing for Corrosive Environmental Conditions The stainless steel housing and sealing structure protect components from corrosion damage
By equipping not ...
|
|
Fisher Fisher – What are the causes and ways to eliminate leaks in valve disc and seat seals?
There are two types of leakage between the valve core and the valve seat: 1. Damaged leakage; 2. Valve position leakage.
For metal-sealed valves, breakage leakage refers to the default sealing line between the valve core and the valve seat, which makes the sealing line disconnected.
|
|
Classification and precautions for use of Fisher valve positioners
Fisher Fisher Valve Positioner Type, according to the structure, is divided into Fisher 3660/3661/3710/Pneumatic Valve Positioner, FISHER3528I Electric-Pneumatic Valve Positioner and Fisher DVC6200/DVC2000 Digital Intelligent Valve Positioner, which has single acting and double acting, and is the main attachment of the control valve.
|
|
Fisher Valve Knowledge – Check Valve Should Be Installed Before or Behind the Outlet Valve
Check valve, also known as check valve, is an automatic valve, which relies on the pressure of the flowing medium in the pipeline to push the valve disc to achieve the closure and opening of the valve.
|
|
Fisher Fisher - What is the difference between a valve limit switch and a valve positioner DVC6200
What is the difference between a valve limit switch and a valve positioner? Many novices don't know much about the product, and today I think I will answer the difference between the valve limit switch and the valve positioner!
1. The valve limit switch is also called a return signal, which is actually a display (reaction) valve switch ...
|
|
Fisher Nuclear Control Valve Advantages:
Emerson Process Management has been serving the nuclear industry for more than 40 years. The company's Fisher nuclear control valve series is used in 90% of the world's nuclear power plants with excellent reliability. Currently, with the expansion of the size of the enterprise and the professional network of many nuclear applications around the world...
|
|
Fisher Fisher – Commonly used valve packing types and functions
1. Compressed filler
(1) Plant fiber filler
Made of hemp or cotton impregnated with oil, wax or other impermeable materials for use on low-pressure valves below 100°C. It is suitable for water, ammonia and other media.
(2) Asbestos fiber filler
Asbestos fibers have good heat resistance, can resist weak acids, strong alkalis, ...
|
|
Industrial Automation - Reason for the Popularity of Smart Valve Positioner Fisher(DVC2000/6200)
Fisher (DVC2000/6200) intelligent valve positioner, just we have the quantity, good price, high quality, choose Dr. Xiangjing valve instrument inventory dealer, is your wise choice, there is a first-class technical team to escort you.
With the process of industrial automation, the ...
|
|
Fisher Flow Amplifier ASCO 614 Series Solutions
The Fisher/fisher ASCO Series 614 SentronicPlus is a digitally operated, three-way proportional regulator. Adjustable pressure, flow, force, speed, and linear or angular position. Air and inert gas media can be controlled. According to the ATEX Directive 2014/34/EU, its structure ...
|
|
Fisher Fisher - Valve*** should be ready to go out into the world
Valves should be prepared to go to the world
, to have a sense of innovation. With a sense of innovation, it will motivate enterprises to work hard and seize opportunities. Wenzhou Yongjia market Longwan market and other areas of the valve industry has a lot of enterprises still use the family workshop model, urgently need to establish a modern ...
|
|
A detailed description of the Fisher control valve nameplate
This article today gives you a detailed introduction to the basic information of the United States Fisher control valve nameplate, the information on the Fisher nameplate, you can click on the attachment to view.
location + number 865 represents Tianjin Fisher factory production, 382 represents Malaysia factory production, and of course ...
|
|
Fisher valve positioner commissioning steps
Fisher valve positioner commissioning steps
Step 1: Connect the Rosemount 475 communicator
1. Enter the interface and select HART; Enter after selecting online; If there is an alarm signal, select YES and enter;
2. Select configure from the online drop-down menu and press the ente ...
|
|
Fisher Fisher – How to Choose the Right Valve Actuator
In order to successfully automate a process, it is important to ensure that the valve itself meets the special requirements of the process and the medium in the pipeline. Usually the production process and process medium determine the type of valve, the type of spool, and the structure and material of the trim and valve. Valve selection is good ...
|
|