|
What are the common faults of Omron PLC?
1. CPU abnormality: When the CPU abnormality alarms, check the devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. Memory abnormality: When the memory is abnormal alarm, if it is a program ...
|
|
Omron Heater Status Monitor K7TM was officially released
In June 2022, Omron Automation (China) Co., Ltd.'s new product [Heater Status Monitor K7TM] was officially released. Without going to the site, through real-time monitoring of heater status, the aging trend of heater equipment that cannot be captured manually is clearly displayed, and predictive maintenance is realized!
In high temperatures ...
|
|
Omron Medical Electronic Blood Pressure Monitor HEM-7071 Features:
1. Intelligent upper arm sphygmomanometer for more accurate measurement
2. Enlarge the screen, completely from the user's point of view
3. It can record 84 measurement results for 2 people respectively, and the total storage value is 168 times
4. The new "Fit Cuff" armband, which is easier to roll up, is adopted.
|
|
Omron products are used in fully automated high-speed sewing and cutting
Process introduction
The sewing and cutting line is mainly used for sewing and cutting shirt collars, sleeves and pockets, and the equipment is divided into the following 4 parts:
1. Discharging part: used for the initial positioning of sewing materials, the laser projection position is controlled by the motor, and the materials are manually placed on the platform.
|
|
Omron MMC Health Convenience Store is once again stationed in Xi'an
On May 12, Omron Health Care (China) Co., Ltd. and Xi'an Yikang Pharmaceutical jointly built Xi'an Yikang Pharmaceutical Youyi West Road Store MMC Health Convenience Store (No. 105, 1st Floor, Life North District, Optical Machinery Institute, No. 121 Youyi West Road, Beilin District, Xi'an City) was officially opened and put into operation. The double ...
|
|
The application of Omron tension control in automobile motor winding
Process introduction
In recent years, the motor industry has shown a rapid upward trend, new products, new technologies are constantly updated and iterative, resulting in increasingly fierce competition between motor manufacturers, how to improve equipment performance, improve productivity, is the current motor manufacturers need to solve the problem.
...
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
Omron PLC troubleshooting
1. Power check:
The first thing to analyze is the reliability of the power supply and ground of the Omron PLC. Visually inspect power and ground cables for damaged, corroded, or other suspicious links.
Power supplies can also be electrically tested. If there is AC power in the PLC processor, test ...
|
|
Common problems and solutions of Omron PLC
1. Omron PLC cannot be connected to the computer
There are two reasons why the PLC and the computer cannot be connected: hardware and software.
The hardware reasons are: the interface type does not match (such as USB, RS232, RS422, RS485, CAN, etc., both sides should be the same.) If you want to use the corresponding converter if you want to), ...
|
|
Omron PLC--C200HE/C200HG/C200HX series product model
1. C200HE-CPU11-E CPU unit memory 3.2K maximum I/O points: 640 points
2. C200HE-CPU32-E CPU unit memory 7.2K maximum I/O points: 880 points
3. C200HE-CPU42-E CPU unit RAM 7.2K Max I/O points: 880 points with RS232C ...
|
|
【Omron industry case】Application of high-end pouch battery welding machine
Process introduction
In the middle process of the secondary battery, the battery welding machine first needs to quickly heat press the battery cells after winding/lamination to achieve cell compaction, and then ultrasonic welding of the positive and negative tabs of the battery cells.
problem
1. Pressure fluctuates greatly, causing ...
|
|
Wiring method of Omron PLC
The connection method is as follows: the brown wire is connected to the PLC input point, the PLC com point is connected to the positive pole of the power supply, and the negative pole of the power supply is connected to the blue wire.
NPN type: brown is connected to the positive power supply, blue is connected to the negative power supply, the black wire is connected to the PLC input point, and the PLC com point is connected to the positive power supply. NPN is a leak type, and the detected object ...
|
|
Common fault problems of Omron relays
1. Do not exceed the rated voltage of load current during the use of OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And it may also cause a succession ...
|
|
What are the common faults of Omron relays?
Fault 1:
Do not exceed the rated voltage of the load current during the use of the OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And there are ...
|
|
Omron Fiber Optic Amplifier – A common failure of fiber optic amplifiers
1. The optical power meter is not accurate, the domestic optical power meter can only test the equipment with small optical power output, and cannot test the EDFA with high power output, and the optical power meter of the optical amplifier must be imported originally, and the inaccurate instrument can not be used as a standard.
2. The flange of the output port is damaged ...
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
Instructions for the incorrect operation of Omron micro switches
Operation point one
During the installation and operation of Omron micro switches, please remember that the direction of action of the operating mechanism of the switch cannot be reversed, otherwise it is easy to cause the fault of the line. Moreover, the position of the switch should meet the requirements of the control circuit and ensure reliable operation. For micro ...
|
|
The correct use and precautions of Omron electronic blood pressure monitor
How to use Omron blood pressure monitor
1. Rest for 10-15 minutes before using an Omron sphygmomanometer to measure blood pressure to eliminate fatigue and excitement.
You must rest for 30 minutes after exercising. The indoor ambient temperature should be kept at about 20°C. Take 3-4 deep breaths before measuring your blood pressure. Lying ...
|
|
Extended unit address assignment for Omron PLC
2. Extend unit address allocation
The function of the expansion unit is to expand the input and output, and the expansion unit starts from the next channel after the allocation channel of the CPU unit, and assigns the address backwards.
CP1W Expansion Unit
For example, the CPU unit comes with an input that occupies 0 channels and 1 pass ...
|
|
Omron Relays – How relays work
1. Rated working voltage.
The voltage required by the coil for the relay to operate normally.
Depending on the model of the relay, it can be either AC voltage or DC voltage.
2. DC resistance.
The DC resistance of the coil in the relay can be used with a multimeter ...
|