1. The indicated value is large (or out of range).
According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the instrument indication, and the value is drunk. Of course, don't panic if there is a problem, and replacing the float in time can solve this kind of problem.
2. The float does not change with the liquid level and is in a high position
When we find this kind of situation, it is usually the problem of the float in the float level gauge, but it is not damaged, it may be caused by the float falling off. In this case, the staff only needs to check and reinstall the float in time.
There is also a situation, that is, because the customer's tank is made of magnetic metal, the float is too high in the case of rising liquid level, because there is a magnet in the float, and the coupling effect with the tank, the float is sucked, and in the process of the next liquid level drop, the float is always in, and the external performance is that the liquid level value does not change, and is always at a high point. In this case, the influence of the tank material on the float is not considered in the selection and production stage, and the remedy is to set up a fixed point clamp at the lower end of the float that is sucked, so as to achieve that the float cannot reach the position where it is sucked.
3. The indicated values are generally low
There are many reasons for this, and it can also be caused by the drop off of the float occasionally, as well as the breaking of the connecting rod between the floats, or damage to the hands or heads of the floats. Therefore, it is very important for us to carefully check when solving this problem.
For example, we need to check that the compression gauge is working properly; whether the float link can be twisted flexibly; Whether the pointer and meter head are damaged, if there is no problem, it should be a broken connecting rod, and the connecting rod can be replaced. However, if there is still a fault after replacement, there must be a loophole in the previous inspection, please check it again.
4. The transmitter of the float level gauge suddenly has no indication
When there is no abnormality in the measurement display, that is, the polarity is not reversed, and there is no power output on the current conversion side, it must be that the instrument head is damaged, and the staff can solve the problem by repairing or replacing the instrument head in time.
|
More on that
|
Focusing on the field of logistics sorting, the fifth-generation AC servo drive of Buke is listed!
Since the new crown epidemic, the rapid growth of e-commerce has made the overall scale of China's express delivery industry grow rapidly, according to incomplete statistics, the business volume in 2020 has exceeded 80 billion pieces. Due to the growth of express delivery business volume, the automatic sorting efficiency of express delivery and parcels is becoming higher and higher.
|
|
Buke servo motor - how to care for and maintain servo motor
1. Regularly check the encoder connection line of the servo motor and the power connector of the servo motor to confirm that they are firmly connected;
2. If the servo motor is connected to a reduction gear, the servo motor should be sealed with oil to prevent the oil from the reduction gear from entering the servo motor.
...
|
|
Buke servo motor - AC servo motor vibration fault analysis
Mechanical
1. Bearing
The bearing clearance on the lead screw housing is too large after wear, or the bearing roller elements and cages are severely worn due to the lack of grease in the bearing, resulting in excessive loads. After bearing wear, the clearance is too large, which will cause the coaxiality error between the center of the motor rotor and the center of the lead screw.
|
|
Buke successfully passed the fourth batch of specialized, special and new "little giant" enterprise identification
Recently, the Ministry of Industry and Information Technology of the People's Republic of China has completed the review of the fourth batch of specialized, special and new "little giant" enterprise cultivation, and publicized the list of enterprises that have passed the review.
|
|
Classification and characteristics of the human-machine interface of Buke
MT4000 series
MT4000 series HMI is a sub-series of eView HMI, which is one of Buke's HMI products
Series, human-machine interface MT4000 is referred to as ordinary application series. MT4000 series HMI products adopt 32 ...
|
|
Buke servo motor - what is the main function of servo motor encoder
1. Servo motor encoder is a product installed on the servo motor, which is equivalent to a sensor.
2. Do speed closed-loop and azimuth closed-loop to complete accurate speed regulation and accurate azimuth control.
3. The servo motor has its own encoder, which can be converted into servo electronic gears.
|
|
The kick-off meeting of the organizational reform project of Buke Co., Ltd. was a complete success!
On December 17, Buke Co., Ltd. and Willis Towers Watson (formerly Torrei Watson, the world's leading professional services company) held the "Buke Co., Ltd. Organizational Reform and Upgrade Project Kick-off Meeting". Xu Changliang, Chief Consultant of Willis Towers Watson, Sheng Shaoqin, Partner of Willis Towers Watson, Tang Dong, Chairman of Buke Group, Bu...
|
|
Buke servo motor - wiring connection of servo motor encoder
(1) Wiring should be done with the power supply OFF, and if the output line is in contact with the power supply when the power is turned on, the output circuit may be damaged.
(2) If the wiring is incorrect, the internal circuit may be damaged, so pay full attention to the polarity of the power supply when wiring.
(3) If and high-voltage lines, ...
|
|
Common faults of Buke servo motors
What are the power requirements for hardware setup 1, ED100 and ED200? The logic power supply of the Kinco servo is DC24V (scale is 18V-30V), not less than 1A (if the boundary says OUT and Brake output, it is not less than 2A); The power supply of ED100 is DC24V-DC70V, and the power supply requirements of ED200 and ED216 are D...
|
|
Buke servo motor - introduction to the control mode of DC servo motor
There are two main control methods of DC servo motor: one is armature voltage control, that is, under the condition that the stator magnetic field remains unchanged, the speed and output torque of the motor are controlled by controlling the voltage signals applied to both ends of the armature winding; The other is the excitation field control, that is, by changing the ...
|
|
Buke servo motor - a detailed explanation of the three control modes of the servo motor
1. Servo motor pulse control mode
In some small stand-alone equipment, the use of pulse control to achieve the positioning of the motor should be the most common application method, this control method is simple and easy to understand. The basic control idea: the total pulse amount determines the motor displacement, and the pulse frequency determines the ...
|
|
Buke servo motor - the division of the motor and its detailed introduction
1. According to the type of working power supply: it can be divided into DC motor and AC motor.
1) DC motors can be divided into brushless DC motors and brushed DC motors according to their structure and working principle.
Brushed DC motors can be divided into: permanent magnet DC motors and electromagnetic DC motors.
|
|
Buke human-machine interface - anti-interference countermeasures of PLC controller and human-machine interface
1. Adopt a power supply with excellent performance to suppress the interference introduced by the power grid.
For the power supply supplied by the PLC controller, the non-power line power supply should be adopted, and the special line power supply should be used directly from the main bus of the low-voltage distribution room. Isolation transformers are selected, and the transformer capacity should be larger than the actual needs.
|
|
Buke servo motor - fault and treatment of three-phase asynchronous motor(1-5)
1. The motor cannot rotate after being energized, but there is no abnormal noise, no peculiar smell and smoke.
1. Cause of failure
(1) The power supply is not connected (at least two phases are not connected);
(2) Fuse blowing (at least two-phase blowing);
(3) The overcurrent relay is adjusted too small;
(4) Control ...
|
|
Buke servo motor - AC servo motor maintenance method
1. Please ensure that the environment is clean and avoid oil. When used in dusty and humid places, although the protection level of the servo motor is very high, it will be easy to cause problems if it is often used in such an environment.
2. Regularly check the use of the servo motor to see if there is any damage outside.
|
|
Buke touch screen - the classification of touch screen and its characteristics introduction
1. Resistive touch screen
The most important part of a resistive touchscreen is a resistive thin-film screen that matches the surface of the display very well. This is a multi-layer composite film based on a layer of glass or hard plastic plate, coated with a transparent metal oxide (ITO indium oxide, transparent conductive ...
|
|
Buke servo motor - a common fault of AC servo motor
1. Bearing failure is one of the most common motor failures. As the most important consumable part in servo motors, more than half of the failures of servo motors are usually caused by bearing problems. Its specific manifestations are varied, from jitter and abnormal noise when the motor rotates to the jamming of the motor shaft. Value...
|
|
Buke servo motor - fault and treatment of phase asynchronous motor(6-11)
6. When the motor is unloaded and overloaded, the ammeter pointer is unstable and swings
1. Cause of failure
(1) The cage rotor guide bar is welded or broken;
(2) Winding rotor fault (one-phase break) or poor contact of brushes and collector ring short-circuit devices.
2. Troubleshooting
...
|
|
The solution of the alarm code 08 when the servo drive is accelerated
1. Please check the motor power line to confirm whether there is a short circuit in the phase wire of the motor
2. If there is no short circuit in the phase line of the motor, it is determined that the internal power tube problem of the driver is determined
|
|
Buke servo motor - the cause of common faults in motors
1. Sweeping: Sweeping is generally caused by friction of the stator and rotor due to bearing damage, shaft bending, or improper assembly during maintenance. In the process of overhaul and assembly of the motor, the parts of the motor should be kept clean, and the assembly of the end cover, bearing, etc. should be reasonable and not barbaric construction, otherwise ...
|
|