My name is Inverter, and among the many new energy-saving products, I am known as the "energy-saving forward" for my excellent function.
In today's world, extreme disasters are frequent, with melting glaciers, rising sea levels, persistent droughts, and torrential rainfall...... It is a serious threat to human livelihoods. Today, energy conservation, emission reduction and environmental protection have become important issues that mankind must face together. I was born in this climate.
Inverter, Wangwen Shengyi, is a kind of comprehensive use of frequency conversion technology and microelectronic technology to change the frequency and amplitude of the working power supply of the motor to control and communicate the electric transmission of the motor. My birth is the embodiment of human wisdom and sweat.
In order to ensure the safe and reliable operation of fans, pumps and other equipment, engineers have left a certain surplus when planning to use power drives. When the motor is not running at full load, the remaining torque adds to the active power consumption, which constitutes the waste of electrical energy. For example, it takes a half-horse to pull a cart of goods up a high slope, and people usually pick two horses to complete the task. Isn't there still half a horse here that hasn't worked yet? Obviously, if you match the goods according to the carrying capacity of the horse, you can reduce the waste and maximize the benefits. The same principle can be applied to the power drive surplus. If the speed of the motor can reach the requirements of people in real time, then the energy lost in the system will naturally be reduced!
In order to accomplish the useful manipulation of electric drives, scientists have made bold innovations. In 1967, the world's first inverter was successfully developed and put into commercial operation. Through more than 40 years of development, communication motor frequency conversion speed regulation has become a major means to save electric energy, improve production process, improve product quality, and improve the operating environment. Correspondingly, our inverters are widely loved by users for their high efficiency, high power factor, and excellent speed regulation and starting and braking functions, and play an important role in many fields.
The first is the soft-start function. The motor is hard to start, the direct start current is often 3-5 times of its rated current, and the sudden increase in current not only adds to the difficulty of planning and production of the motor, but also poses a serious impact on the capacity of the power grid system, transmission and distribution equipment, and the damage to the baffle, valve and other equipment is also great. My effect is to change the frequency and amplitude of the power supply of the communication motor, so as to change the period of its moving magnetic field, so as to achieve the intention of lubricating the speed of the motor. This makes the motor starting current from zero and gradually added, and the maximum value does not exceed the rated current, which reduces the impact on the power grid and the requirements for power supply capacity, and prolongs the service life of the equipment.
The second is to optimize the operation of the motor. In the fan, central air conditioning and other systems, the traditional water supply method is completed by using water towers, high-level water tanks, air pressure tanks and other equipment. The water pressure at the outlet is often affected by factors such as the height of the water tank and the amount of water storage, and often changes, and it is not simple to truly complete the constant pressure. In addition, the traditional speed regulation method of fans, pumps and other equipment is to adjust the air supply and water supply by adjusting the baffle plate and valve opening of the inlet and exit. When the input power is too large, a large amount of energy is consumed in the process of intercepting the flow of the baffle and valve, which constitutes a waste. It's like people transporting bricks that greatly exceed the required amount of bricks to high-rise buildings without accurately calculating the amount of work, which constitutes a waste of manpower and man-hours. Now, engineers combine inverters, PID conditioners, microcontrollers, PLCs, etc., to form a control system, which can regulate the output flow of the pump and reduce ineffective labor. As long as people set the outlet pressure of the pumping station main, the setting value is compared with the practical value of the feedback, and the difference is processed through calculation, and the system will announce the control instruction to control the number of units and speed of the pump motor, so as to reach the policy of stable pressure of the water supply main. Compared with the conditioning valve to control the water pressure, the system reduces the resistance of the pipeline, greatly reduces the efficiency of interception loss, and does not require manual frequent operation, which reduces the labor intensity. Now, I am busy in places such as water plants, daily communities, fire water supply systems, sewage lifting and treatment systems, agricultural drainage and irrigation, and music fountains.
In the central air conditioning, fan and other systems, we also have a good embodiment. Central air conditioning is planned according to the maximum demand for cold (heat) plus 10-20%, which consumes a lot of electricity and has great potential for energy saving. Use me to regulate the speed and energy-saving control of the central air conditioning refrigeration compressor, refrigeration pump, cooling pump, cooling tower fan, return air device, etc., which can avoid excessive flow and excessive pressure, ensure the normal and useful operation of the system, and save 20%-50% of electricity. For another example, during the construction of the Shanghai Yangtze River Tunnel, the "first tunnel of the Yangtze River", the builders needed to ensure that the tunnel with a length of about 8.9 kilometers and an inner diameter of 13.7 meters was well ventilated. To this end, this project selected Delixi inverter, according to the size of the air volume directly given the motor speed, precise adjustment of the air volume, optimize the use of electrical equipment, energy saving of 20%-45%.
Along with the economic benefits, the social benefits of the inverter are also very obvious. It is estimated that the inverters that ABB Group has produced and installed worldwide alone can save 115 billion kWh of electricity per year, reducing carbon dioxide emissions by 97 million tons, which is more than Finland's annual carbon dioxide emissions.
The third is to have a protective function for the system. After detecting the abnormal state in the system, I can actively correct the action or close the PWM control signal of the power semiconductor equipment, so that the motor can actively park, such as overcurrent loss speed prevention, overcurrent blocking, semiconductor cooling fan overheating and instantaneous power failure protection.
After listening to my confession, you will think that I am a veritable "energy-saving striker", so please give me the opportunity to give full play to the effect on the day of production!
|
More on that
|
Delixi three-phase circuit breaker classification
Delixi's three-phase circuit breaker is generally divided into three types, namely 3P, 3P+N and 4P.
(1) Differences:
3P: Only three wirings are used for pure three-phase electrical equipment, which trips when there is no single-phase load to the ground or when there is a short circuit between phases; Otherwise, when a one-phase N-line load occurs, the N-line is disconnected ...
|
|
A brief introduction to Delixi leakage circuit breaker
Delixi leakage maintainer is mainly when the electrical equipment leakage problem to provide maintenance of the device, when the installation of leakage maintainer, should be other devices overcurrent maintenance device. When the fuse is used for short-circuit maintenance, the selection of its standard should be compatible with the on-off of the leakage maintainer. Appear...
|
|
The main factor affecting the poor heat of the instrument - Delixi
The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different samples are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...
|
|
Delixi inverter installation and wiring
1. The device of the inverter
1.1 The device environment requirements of the inverter
Ambient temperature - 10 °C - 40 °C;
Ambient humidity: The relative humidity does not exceed 90% (no condensation);
Other occasions requiring no direct sunlight, no corrosive gas and flammable gas, less dust, ...
|
|
Regularly inspect the inverter steps and methods - Delixi
When the VFD is viewed regularly, the power supply should be blocked, the operation of the VFD should be stopped, and the cover of the VFD should be removed. The first thing is to check the places that cannot be seen without downtime, or the places where it is difficult to find problems on a daily basis, as well as the inspection and adjustment of electrical characteristics.
After blocking the VFD power supply, the main power ...
|
|
How to distinguish the authenticity of Delixi Electric
Delixi switch socket real and false distinction
1. Appearance
The shape of genuine Delixi switches is relatively fashionable, looks beautiful, neat appearance, and other impact resistance functions are relatively strong, not easy to crack or turn yellow. Whereas...
|
|
Classification of low-voltage electrical appliances - Delixi
1. Classified according to the operating voltage level
Low-voltage electrical appliances: electrical appliances used to communicate circuits below 1200V and DC 1500V to play the role of on/off, protection, control or regulation.
High-voltage electrical appliances: communication 1200V or more, DC 1500V or more.
...
|
|
Delixi contactor has normally open point and normally closed point reasons
If you're wondering why there are normally open and normally closed contacts in communication contactors, let's first look at what these contacts are used for. Normally open and normally closed contacts are electrical components used to complete self-locking, interlocking or interlocking tasks, and can also be used to control other components or signal indicators.
|
|
Leakage protector leakage cause - Delixi
1. Poor device
If the terminal posts of the leakage protector are not firmly connected during the installation, it will often lead to the heating and oxidation of the terminal post for a long time, so that the wire insulation layer will be scorched, and accompanied by the smell of ignition and rubber and plastic burning, forming an undervoltage of the line and tripping the leakage protector.
...
|
|
Delixi relay maintenance method
Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical voltage, current) or non-electrical quantity (heat, time, speed, etc.) to complete the control or maintenance mission.
|
|
Delixi inverter constant pressure variable frequency water supply system control problem
1. The pressure of Delixi inverter system is unstable and easy to vibrate?
Answer: The pressure of the system is unstable, which may be due to the following reasons:
A. There is a problem with the direction of the pressure of the pressure sensor acquisition system, and the pressure collection point is too close to the water outlet of the water pump, and the pressure of the pipeline is affected by the water outlet ...
|
|
Linear and switching regulator features
The advantages of linear DC regulator are high stability, small ripple, high reliability, and easy to make a multi-output connected adjustable power supply. The disadvantages are large size, bulkiness, and relatively low power.
There are many kinds of this kind of regulated power supply, which can be divided into regulated power supply, stabilized current power supply and ...
|
|
Delixi inverter EM60 series model introduction
S1 (Single-phase 110V, 50/60HZ)
CDI-EM60G0R75S1 0.75KW
CDI-EM60G1R5S1 1.5KW
S2 (Single Phase 220V, 50/60HZ)
CDI-EM60G0R4S2 (without built-in brake unit) 0.4KW
CDI-EM60G0R4S2B (Built-in ...
|
|
The inverter is changed to a servo to consider the key points
There are substantial differences between servos and inverters in terms of application intention and function. Which one to choose depends on factors such as operating mode, load conditions, price, etc. Basically, the performance of the servo is superior to that of the inverter. Therefore, when changing from an inverter to a servo, there are generally no operational problems ...
|
|
Delixi spare parts replacement cycle
1. Cooling fan (2-3 years)
As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.
|
|
A brief introduction to three-phase transformer - Delixi
All large AC power blocks are connected by a three-phase transformer for transmission and distribution at high voltage levels. Single-phase transformers can be electrically connected to form a three-phase transformer bank in a distribution system. But the standard is to combine a single phase coil into a three-phase transformer unit on a common core ...
|
|
The treatment method of leakage protector often tripping - Delixi
1. Trial delivery and commissioning method
The first thing to find is the fault of the remaining current action maintainer itself. The detailed operation method is: first block the power supply, and then remove all the zero-sequence transformer load side leads of the remaining current action maintainer (the second and third level remaining current action maintainers will directly remove the outgoing ...
|
|
Voltage regulator power selection and determination - Delixi
1. The output power of the voltage regulator is the maximum power
Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.
|
|
Low dropout linear regulator application type - Delixi
1.AC/DC the use of power supply
Schematic diagram of the use of low-dropout linear regulators in AC/DC power supplies. In this circuit, the AC voltage is stepped down by the power transformer to obtain the low voltage of communication, and then the unstable DC voltage is obtained through the rectifier filter circuit, and then the voltage is regulated linearly by the low dropout ...
|
|
The difference between air switch and leakage protection switch - Delixi
(1) The function is different.
An air switch is a kind of circuit breaker that maintains "something", which can maintain the safety of the entire household wiring and appliances, and avoid the overheating and burning of the wires.