1. Extremely high;
2. The appearance is RAL7035 color (gray and white), which is consistent with the cabinet;
3. Ultra-thin design, the installation method can be plug-in and embedded;
4. The power supply range, single-phase and three-phase power supply models can be selected;
5. The controller is operated by digital display and buttons, with temperature display and high and low temperature alarm display, etc.;
6. The display and controller are integrated, no electric control board, and more resistant to harsh working environment;
7. All models have passed the third-party performance test and certification, and meet the DIN3168EN815EN14511 standards, refrigeration capacity and performance;
8. Environmentally friendly refrigerant R134A;
9. Standard Chinese and English manuals;
10. Passed CE certification;
11. Standing inventory, fast delivery;
12. Optional configuration: built-in evaporation device to solve the problem of condensation
|
More on that
|
Introduction to the process characteristics of the Rittal cabinet - PS frame universal control cabinet
1. The cabinet door is 25mm from the ground and 2.5mm thick mounting plate, and there are 20mm wide U-shaped curved edges on both sides, which makes the mounting plate stronger and easy to handle.
2. The three cable introduction cover plates at the bottom of the box can be replaced with each other, which is easy to move, easy to import cables, and easy to open holes into the line.
3 ...
|
|
How to choose a distribution box for home renovation - Rittal
1. Determine the material of the distribution box
First of all, from the material selection, the distribution box on the market is divided into plastic and metal two materials, metal material is durable, strong resistance, but it is easy to rust and corrode when encountering water stains; Although plastic is light and cheap, it is not very durable. Therefore the root ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What are the types of electric shocks?
Answer: Direct electric shock, indirect contact electric shock, induced voltage electric shock, lightning electric shock, electrostatic electric shock.
What are the organizational measures to ensure safety when working on electrical equipment?
Answer: work ticket system, operation ticket system, inventory site and comprehensive ...
|
|
Rittal cabinets – daily maintenance methods for high and low voltage distribution cabinets
Complete set of electrical maintenance knowledge:
1. Low-voltage distribution cabinet
1. Regularly check whether there are traces of pest activity in each cabinet, and carry out trapping regularly.
2. Check whether the warning signs and maintenance signs are placed correctly.
3. Check whether the emergency tools and lamps are in order.
|
|
Rittal cables – common causes of cable failure
1. External force damage. Judging from the operation analysis in recent years, especially in Haipudong, which is developing rapidly, a considerable number of cable failures are caused by mechanical damage. For example, the cable laying and installation is not standardized, which is easy to cause mechanical damage; Engage in direct burial on cables ...
|
|
Here's a quick overview of what products Rittal makes
Many customers don't know what products Rittal makes, so today I will simply classify Rittal products. Rittal products are mainly divided into 6 categories below 6
(1) Rittal control cabinet: small cabinet (here can also be subdivided polycarbonate cabinet PK, junction box KL, compact control box EB, ...
|
|
For the first time, the Rittal Rittal and Circle B and Switch data centres have launched the European OCP Experience Centre
Circle B, Rittal and Switch data centres in Germany launch the first European Open Computing Project (OCP) Experience Centre. The full-featured OCP environment is located at one of the facilities of three switching data centers in the Amsterdam area. (The OCP Experience Center can be used as a demo center, but it is also ...
|
|
Rittal outdoor cabinet + temperature control solutions for you to provide comprehensive protection
Rittal's outdoor cabinet + temperature control solution provides 1+1 >2 business value, combining the demands of "function and safety" into one, and guarding it in one stop. Whether it's wind, rain, lightning erosion, scorching sun exposure or blizzards, Rittal outdoor system solutions can be used all the way ...
|
|
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets
What is eddy current? What are the harms of eddy currents?
Answer: When an alternating current is passed through a wire, an alternating magnetic field is created around the wire. An induced current is generated inside the whole conductor in an alternating magnetic field, and because this induced current forms a closed loop inside the whole conductor, ...
|
|
Rittal air conditioner alarm code parsing
1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect;
2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small;
3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...
|
|
Rittal won the Best Partner Award from Hengxin Software and Yokogawa Automation
Sincere service, strength and responsibility
In 2022, which was full of changes, Rittal and its partners Hengxin Software and Yokogawa Automation (part of the Yokogawa Group) withstood the challenges brought about by the pandemic and moved forward hand in hand. In the cooperation project, Rittal worked with the customer to overcome difficulties and complete the project delivery in a timely manner, ...
|
|
What you need to pay attention to when choosing a Rittal-like cabinet and a Rittal-like electrical cabinet
In recent years, Rittal cabinets have been increasingly used in important equipment and projects at home and abroad. This brand from Germany Rittal cabinet has always been a tall image in the industry, the fine quality is fascinating, and the high price makes us prohibitive. With the agility of China's manufacturing industry...
|
|
Rittal cabinet - judgment and treatment of high-voltage switchgear opening faults
Opening faults can also be divided into mechanical faults and electrical faults. Electrical faults mainly include open control loops, coil faults, auxiliary switch faults, etc.
1. Fault phenomenon: when the red light is not on, the electric cannot be opened, which is the fault of the auxiliary switch. When the opening coil burns out, there is smoke, odor, insurance ...
|
|
What is the difference between a control cabinet and a distribution box?
One. The nature is different
Distribution box: There is a large amount of parameter data in the distribution box. It generally constitutes a low-voltage distribution box.
Control cabinet: The control cabinet is to assemble the switch cabinet, measuring instruments, protection devices and auxiliary equipment in a closed or semi-enclosed metal cabinet or screen according to the requirements of electrical wiring.
|
|
Rittal & Lithium Battery The industrial transformation of the trillion-dollar new energy vehicle market
The power of the 10 billion market
With the help of continuous favorable policies, China's new energy vehicles have maintained rapid growth this year. According to data from the China Association of Automobile Manufacturers, the production and sales of new energy vehicles reached a new high in October, with a year-on-year increase of 87.6% and 81.7% to 762,000 and 714,000 units, respectively.
|
|
Rittal enclosures – how do you maintain your robot control cabinet?
1. Maintenance content
(1) Check the heat dissipation of the controller
It is strictly forbidden to cover the controller with plastic or other materials; Leave enough space behind and on the sides of the controller (> 120mm); It is strictly forbidden to position the controller close to the heat source; It is strictly forbidden to put sundries on the top of the controller; Avoid over-the-top ...
|
|
Rittal guards the clear sea with the power of "wisdom".
Under the development trend of "green + intelligence", the maritime industry is seizing innovation opportunities, promoting the use of information technology and artificial intelligence in onboard equipment, and actively exploring the development of green ships and intelligent ships.
Rittal makes intelligence ubiquitous, empowers ship digitalization with technology, ...
|
|
Rittal cables – classified according to the purpose of the cable and the environment in which it will be used
1. DC cable
(1) Tandem cables between components.
(2) Parallel cables between strings and between strings and DC distribution boxes (combiner boxes).
(3) The cable between the DC distribution box and the inverter.
The above cables are all DC cables, outdoor laying ...
|
|
Advantages of Rittal cabinets
1. Rittal cabinet can be divided into three series from the structure, ES cabinet (five-fold profile cabinet), PS cabinet (nine-fold profile cabinet), TS cabinet (sixteen-fold profile cabinet), the biggest feature is that the Rittal cabinet is the selection of profile structure structure, the structure of the cabinet is welded first, and then the top plate, bottom plate, side panel, door...
|
|
Rittal cabinets – installation steps and rules for cabinet placement
Cabinet installation steps:
1. Before installing the cabinet, check whether the exhaust device of the cabinet is stable, whether the number of equipment support plates is complete, and whether the pulleys and support columns are stable.
2. The model, specification and device orientation of the cabinet should meet the planning requirements.
3. Cabinet ...
|
|