Omron PLC online modifies the procedure steps
1. Plug the data cable or network cable into the PLC socket and connect one end to the computer (Ethernet needs to set the computer IP and the IP of the PLC CPU to be in the same network segment)
2. Download the latest program from the PLC, or open the backup program, online program
3. Find the place in the program that needs to be modified.
|
|
Omron Relays – The role of signal relays
1) Expand the scope of control. For example, when the control signal of a multi-contact relay reaches a certain value, it can be changed, interrupted, and connected to multiple circuits at the same time according to the different forms of contact groups.
2) Zoom in. For example, sensitive relays, intermediate relays, etc., with a very small control ...
|
|
The division of the storage area of Omron PLC
1. I/O relay area: there are 30 channels in total, and the address is 000-029. An idle relay or channel can be used as an intermediate relay. The rack slot number is from 007CH to 001CH from the left of the CPU unit.
The I/O address number is represented by 5 digits: 1, single digit, ten digits indicate the relay ...
|
|
Analysis of common Omron fault codes
1. C200H series PLC fault codes:
- E0001: Undefined program error
- E0002: Undefined instruction error
- E0003: Missing Program Error
- E0004: Data error
- E0005: Pointer error
- E0006: ...
|
|
What are the advantages of Omron MOS FET relays?
1. The relay is small and still weldable.
The relays in SSOP/USOP packages feature directly exposed terminals for excellent visibility and easy installation.
2. Ultra-small and lightweight: In addition to SSOP and USOP, ultra-small packages contribute to the miniaturization of devices.
...
|
|
Causes and solutions for E1 fault codes in Omron electronic sphygmomanometers
The E1 fault code usually appears on the display of the blood pressure monitor and indicates that the inflation pressure is too high or too low. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check whether the cuff is worn correctly and whether it is properly tightened.
...
|
|
【Omron industry case】The application of robots in the assembly line of automobile high-pressure oil pump
Equipment Overview
The high-pressure oil pump (abbreviation: HDP) is the main power source to drive the fuel pressure of the automobile engine.
The "high-pressure oil pump robot automatic assembly line" mainly realizes the intelligent supply of each component on the high-pressure oil pump and the automatic assembly of each component by the robot.
Work...
|
|
Omron blood pressure monitor instructions and features
Omron sphygmomanometer uses oscillometric measurement method to measure blood pressure, with high accuracy, generally about ±5 Pa, and the measurement method is relatively simple. At the same time, there is a 21-time memory function, which can easily grasp the blood pressure change gauge.
|
|
Introduction to the functions of Omron's dual-channel intelligent fiber amplifier E3X-MZV
Dual-channel intelligent fiber amplifier
E3X-MZV
Optical fiber sensors are widely used to detect the presence and absence of vibration plates, rechargeable battery pole piece winders, digital product assembly and other equipment.
Omron's new fiber optic amplifier selects the functions and performance required for detection and performance.
|
|
Omron PLC - PLC common fault maintenance and handling methods
1. The CPU is abnormal
When an abnormal CPU alarm, check all devices connected to the internal bus of the CPU unit. The specific method is to replace the units that may cause failures in turn, find out the faulty units, and deal with them accordingly.
2. The memory is abnormal
When the memory is abnormal ...
|
|
What are the maintenance precautions for Omron relays?
1. In the operation of Omron relay, if there is any abnormal sound or other abnormal phenomena, the operation should be stopped immediately, and the professional maintenance personnel should be notified to come for maintenance, and the normal operation can only be put into normal operation after troubleshooting.
2. During the maintenance process, check whether the spring is deformed, old...
|
|
The reason and solution for the ERC light of the DA08C output module of Omron plc
The ERC light of the DA08C output module indicates that the module is faulty, which may be caused by the incorrect electrical structure of the output terminal or the power supply overload.
Solution:
1. Check the electrical structure of the output terminal to ensure that the terminal coil is in correct contact;
2. Check the inside of the module ...
|
|
What are the characteristics of Omron 3G3JZ series inverter?
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
Key points of maintenance of Omron relays
One. The surface of the Omron relay shell installed and used should be free of scratches, cracks and damage, and if there is serious damage, the relay should be replaced in time with intact and the same specification;
Two. In the process of Omron relay maintenance, it is necessary to check whether the contacts of the Omron relay are ...
|
|
The application of Omron in laser welding of the top cover of automotive power battery
Process introduction
The assembly process of automobile power battery and cell section is divided into:
1.Hot pressing 2.Tab welding 3.Adapter welding 4.Coating 5.Into the shell 6.Top cover welding
Among them, top cover welding is the last process, which uses the laser welding process to combine the top cover with ...
|
|
The solution to the E4 fault code on the Omron electronic blood pressure monitor
The E4 fault code usually appears on the display of the blood pressure monitor, indicating that the blood pressure monitor is poorly connected to the cuff or that the cuff is falling off. This failure can lead to inaccurate measurement results or even inability to complete the measurement.
Solution(s):
1. Check that the cuff is worn correctly and whether it is loose...
|
|
How to add SMC module to Omron plc
After adding the I/O module, you need to set it in the CX-PROGRAMMER program.
Find the IO table and unit settings, double-click to find the mainframe [0000], dot + sign, and then double-click 00 (if not set), 00 represents the module number closest to the CPU.
|
|
Omron PLC--CPM2A series product model
1. CPM2A-20CDR-D 20-point CPU unit, DC24V 12-point in, 8-point relay output, comes with RS232
2. CPM2A-20CDT-D 20-point CPU unit DC24V 12-point to 8-point transistor output with RS232
3. CPM2A-30CDR-D 30 points CPU unit DC24V 18 points ...
|
|
The solution to the problem of Omron switches only turning on the green light
For the problem that the Omron photoelectric switch only lights green, it may be because a component on the circuit board is faulty or damaged, or because of the poor connection of a component on the circuit board.
So, to deal with this, the first thing to do is to see if the components on the board are ...
|
|
Omron brought diversified solutions to the digital tour (Jinan Station)!
Recently, the 6th National Digital Upgrade Tour Seminar was held in Jinan. Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") attended the event as a leading automation company, and focused on the pain points in the digital transformation of local enterprises with more than 100 enterprise representatives from various industries.
|