The micro switch is a contact mechanism with a small contact spacing and a quick action mechanism, with the specified stroke and the specified force for the switch action, covered with a shell, and a switch with a driving rod outside, because the contact spacing of the switch is relatively small, so it is called a micro switch, also known as a sensitive switch.
Omron micro switch glossary
Micro switch: A type of switch with a small contact spacing and a snap-action mechanism, a contact structure that carries out the switch action with a specified stroke and a specified force, covered with a shell, and a drive rod on the outside. (hereinafter referred to as switches) with contacts: In the type of switch, the function of the switch is realized by a mechanical switch with a contact compared to a semiconductor switch with switching characteristics. Contact type: An electrical input and output circuit that forms a contact for a variety of applications
Rating: Generally refers to the value that is used as a guarantee benchmark for the characteristics and performance of the switch, such as rated current, rated voltage, etc., provided that specific conditions (type of load, current, voltage, frequency, etc.) are provided.
Resin fixation (plastic terminals): This is a method of improving drip resistance by filling the terminal area with a wire and fixing the part by filling the part with resin to eliminate the exposed live parts.
Insulation resistance: refers to the resistance between non-connected terminals, between terminals and non-charged metal parts, and between terminals and ground.
Withstand voltage: A critical value that does not cause insulation damage after a high voltage is applied to the specified measurement site for 1 minute.
Contact resistance: Indicates the resistance of the contact part of the contact, but generally indicates the resistance value of the conductor that includes the spring and the terminal part.
Vibration resistance: When the malfunction vibration micro switch is in use, the vibration range of the contact closed due to vibration does not separate for more than the specified time.
Impact resistance: Durable impact refers to the impact that the micro switch will not be damaged by the mechanical impact during transportation or installation, and meets the impact within the range of action characteristics.
Malfunction shock? Refers to the impact range in which the contact closed due to impact when the micro switch is used and does not separate beyond the specified time.
Micro switches are generally based on non-auxiliary press accessories, and are derived from small stroke type and large stroke type. Different auxiliary pressing accessories can be added according to the need, and the switch can be divided into various forms such as button type, reed roller type, lever roller type, short boom type, long boom type and so on.
Omron micro switch model
In terms of size, there are small, ultra-small, super small, etc. Functionally, there is a waterproof type. The most common application is the mouse button.
(1) Small micro switch: the general size is 27.8 long, 10.3 wide, 15.9 high, and the parameters are high capacity, low load and other different changes.
(2) Ultra-small micro switch: the general size is 19.8 long, 6.4 wide, and 10.2 high, with different performance of high precision and long life.
(3) Super miniature micro switch: the general size is 12.8 long, 5.8 wide, 6.5 high, and there is an ultra-thin design in this type.
(4) What is the difference between a waterproof tactile switch and a micro switch?
|
More on that
|
The Omron mobile robot can move a payload of up to 250 kg
Omron's LD-250 can be used to transport large automotive parts, such as gearboxes and large quantities of packaging materials, which are normally handled by human workers using trolleys.
The robot is made of a sturdy metal enclosure that can withstand unexpected external shocks and requirements for more ...
|
|
There are five classifications of Omron relays
The function of Omron automotive Omron relay is consistent with the function of ordinary relays, and the relay plays the role of a switch in the electrical automation industry, that is, by controlling the on/off of one circuit, so as to control the intermediate link of the next circuit on/off. Automotive relays are usually made of electromagnetic or solid...
|
|
How are Omron switch relays wired?
One. Before connecting, determine the voltage required for the proximity switch, and in the case of a 3-wire system, determine whether it is PP type or P type. The proximity switch is divided into 2-wire, 3-wire and 4-wire systems.
Two. Wire proximity switches are connected in series when connected to relays. i.e. the relay is connected to the proximity switch to give it ...
|
|
Parameter settings for Omron inverters
1. First of all, set the parameters of Omron inverter according to the rated voltage, rated frequency, rated power and other parameters of the motor;
2. Secondly, according to the actual operation of the motor, adjust the parameters of the Omron inverter to achieve the best operation effect;
3. Finally, ...
|
|
Analysis of the causes of Omron S8 series switching power supply failures
1. Fault phenomenon: After powering on, the power supply does not respond.
2. Cause of failure:
(1) The input power supply voltage is insufficient and does not reach the specified range.
(2) The input power supply voltage is instantaneously impulsed, resulting in damage to the input components (such as fuses, rectifications, etc.) as shown in the figure: ...
|
|
Common troubleshooting methods for Omron relays
First, the contact point is loosened and cracked
The contact point is the electrical contact part of the Omron relay to convert the load, and the contact point of some products is matched with each other by riveting pressure, and the key disadvantage is that the contact point is loose, the contact point is cracked or the error of the standard part is too large. This will jeopardize the relay ...
|
|
The technical cooperation exchange between Omron and Sanhua was held in Hangzhou
Recently, Omron Automation (China) Co., Ltd. (hereinafter referred to as "Omron") and Sanhua Holding Group Co., Ltd. (hereinafter referred to as "Sanhua") held a technical cooperation exchange meeting in Hangzhou. Nearly 100 senior leaders and technical experts from Omron, Sanhua and its subsidiaries attended the meeting.
...
|
|
Omron PLC formatting method
1. Click [Controller] - [Mode] - [Programming Mode].
2. Click [Yes] in the pop-up window, and at this time, the PLC is in programming mode.
3. Click [Controller] - [Clear All Memory].
4. Click [OK], and the PLC memory is successfully ...
|
|
Omron PLC cannot be connected to the computer, and the selected port is temporarily used by another program
Compile first, then click the PLC drop-down menu, select online work, pop up to prepare to connect to the PLC, the point is, if the PLC selected by the program is the same as the actual one, and the COM port is set correctly, there is no problem. After connecting, click on the PLC drop-down menu - > transfer - > from the PLC, and the program will be transferred to the computer. ...
|
|
Omron's new product [Miniature Connector Terminal Block XW2K Series] was officially released
In May 2022, Omron Automation (China) Co., Ltd.'s new product [Miniature Connector Terminal Block XW2K Series] was officially released. The more compact size saves space in the control cabinet, reduces the number of man-hours, and gives the control cabinet a new value!
When it comes to the space footprint of the control cabinet, do you ...
|
|
Omron Heater Status Monitor K7TM was officially released
In June 2022, Omron Automation (China) Co., Ltd.'s new product [Heater Status Monitor K7TM] was officially released. Without going to the site, through real-time monitoring of heater status, the aging trend of heater equipment that cannot be captured manually is clearly displayed, and predictive maintenance is realized!
In high temperatures ...
|
|
Omron announces the opening of its California Robotics Headquarters
March 12, 2020 - Omron Corporation announces the opening of its Robotics and Safety Automation business headquarters in Pleasanton, California. The company has invested $10 million in its 128,000-square-foot facility to design, develop, test and manufacture robots and safe self-propelled robots.
|
|
What are the common faults of Omron relays?
Fault 1:
Do not exceed the rated voltage of the load current during the use of the OMRON relay, because when the applied rated voltage is too large, it may cause a local short circuit between the cores of the OMRON relay coil and poor operation of the AC operation relay. And there are ...
|
|
Features of Omron 3G3JZ series inverter
1. Standard configuration with RS485 interface, Modbus bus communication function;
2. At 3Hz, it can provide more than 150% torque output and start quickly;
3. The carrier frequency of 2-15KHz is adjustable, which can realize silent drive;
4. Equipped with simple energy-saving function;
5. Controlled ...
|
|
Maintenance method of Omron PLC
1. Maintenance procedures, regular testing and adjustment of equipment
(1) Check the connection of the terminal blocks in the PLC cabinet every six months or quarters, and reconnect the loose places in time if they are found;
(2) Re-measure the working voltage of the power supply to the main engine in the cabinet every month ...
|
|
How to use Omron switches
1. When the Omron switch power socket is embrittle or damaged, it must be repaired and replaced immediately.
2. When going out, falling asleep, or suddenly losing power, be sure to cut off the power immediately. Household appliances, in particular, must be more careful.
3. Omron switches and power sockets should be set as much as possible.
|
|
How to modify the program online of Omron PLC?
1. After determining the object in Omron PLC, click Write Mode in the edit window.
2. Next, directly select the relevant software components and double-click.
3. At this time, you need to change the number through the ladder diagram input and select OK.
4. Such a ...
|
|
Key Features of Omron PLC:
(1) Flexible structure
Regardless of the environmental limitations, the network can be built when there is electricity, and the number of access ports can be flexibly expanded, so that the resource utilization rate is high, and it is comparable to WLAN in terms of mobility.
(2) High transmission quality, fast speed and stable bandwidth
Can be very ...
|
|
Introduction to the characteristics of Omron 3G3RX series inverter
1. High starting torque of more than 200% at 0.3Hz, 0Hz to ensure 150% torque output;
2. Closed-loop vector has servo functions such as position control, origin reset, and electronic gear ratio;
3. Over-current and over-voltage suppression function;
4. The fast ...
|
|
The application of Omron in laser welding of the top cover of automotive power battery
Process introduction
The assembly process of automobile power battery and cell section is divided into:
1.Hot pressing 2.Tab welding 3.Adapter welding 4.Coating 5.Into the shell 6.Top cover welding
Among them, top cover welding is the last process, which uses the laser welding process to combine the top cover with ...
|
|