CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching on and off circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A, and can be combined with appropriate thermal relays or electronic protection devices to form motor starters to protect circuits that may be overloaded.
Comply with standards: GB/T 14048.4, IEC/EN 60947-4-1.
Shell Frame Grade: 160-250
Rated insulation voltage: 1140
This article introduces the product interest of CHINT/CHINT CJ40 series AC contactor CJ40-250, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Motor Control & Protection Appliance -JR36 Series Thermal Overload Relay
JR36 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current 0.25-160A long-term work or intermittent long-term work of AC motor overload and phase failure protection.
Thermal relays have phase failure protection, temperature compensation, self-...
|
|
CHINT/CHINT Terminal Appliances — NH4-125 Disconnector
NH4-125 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated current to 125A, rated voltage to 400V in the power distribution and control circuit, mainly as the main switch in the terminal combination electrical appliances, can also be used for infrequent control of various low-power electrical appliances and lighting, widely used in ...
|
|
CHINT/CHINT Time Relay JSS48B Delay 1 Conversion
Introduction: JSS48B series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a delay element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT JZC1 series contactor relays
JZC1 series contactor relay is mainly used in the control circuit of AC 50Hz or 60Hz, rated working voltage to 660V or DC rated working voltage to 600V, used to control various magnet coils and used for amplification and transmission of electrical signals.
|
|
CHINT/CHINT JZC4 series contactor relay
JZC4 series contactor relay is mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 400V and DC rated voltage to 220V, for switching, breaking and amplifying.
Standards: GB/T 14048.5, IEC 6 ...
|
|
CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ
Introduction: NJB1-YW liquid level relay is suitable for automatic water level control in industrial facilities and equipment, civil water towers, high-level water tanks, underground reservoirs and other occasions. This product is not suitable for level control of flammable and explosive liquids such as oil, chemical liquids, etc.
...
|
|
CHINT/CHINT Motor Control & Protection Appliances - NRE8 Series Electronic Overload Relay
NRE8 series electronic overload relay (hereinafter referred to as the relay) is mainly used in the circuit with AC 50/60Hz, rated working voltage below 690V, and the current is within the range of the setting current calibrated by the casing, for three-phase motor overload and phase failure protection.
This relay is an application microcontroller ...
|
|
CHINT/CHINT JZ7 series intermediate relay
JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in the control circuit of AC 50Hz (can be used for 60Hz after derivation), rated working voltage to 380V or DC rated working voltage to 220V, used to control various electromagnetic coils, so as to expand the signal or transmit the signal to the ...
|
|
CHINT/CHINT Time Relay NTE8 Series Reset time ≤1s
Introduction: NTE8 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 415V and DC rated control power supply voltage to 24V, and the circuit is turned on or off at a predetermined time.
...
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ
Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection.
...
|
|
CHINT/CHINT Relay NJX-13FW Size: 27.9x21.9x35.5mm
Introduction: NJX-13FW relay 2Z, 2ZS, 3ZS, 4ZS four contact forms: no oxidation, zero arcing, long life; The transparent cover is sealed and sealed, waterproof, dustproof and anti-corrosion, and can be used in harsh environments such as low air pressure; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available.
|
|
CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker
NBH8-40 □ household circuit breaker is mainly used for AC 50Hz, rated voltage to 230V, rated current to 40A line as overload and short circuit protection of power lines, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances.
Standard: GB/T 10963 ...
|
|
CHINT/CHINT Level Relay NJYW1 Series Control electrode voltage 24V
Introduction: NJYW1 series liquid level relay is suitable for automatic control of liquid level in civil water towers, high-level water tanks, underground reservoirs and other occasions in the control circuit of AC 50Hz and rated control power supply voltage to 380V. Automatic water supply or drainage control can be realized according to the user's wiring requirements. Unwell...
|
|
CHINT/CHINT Solid State Relay NJG1 Series Load power factor 0.5
Introduction: NJG1 series solid state relay adopts photoelectric isolation between input and output, one-way thyristor reverse parallel output, zero-crossing conduction, built-in RC absorption loop, MOV protection, epoxy resin potting. Widely used in electric furnace heating constant temperature system, CNC machinery, plastic machinery, food machinery, ...
|
|
CHINT/CHINT Motor Control & Protection Appliance - NR8 Series Thermal Overload Relay
NR8 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current 0.1A-630A long-term work or intermittent long-term work of AC motor overload and phase failure protection.
The thermal relay also features temperature compensation, action indication, ...
|
|
CHINT/CHINT Relay KG10M Time Control Switch
Product Overview
KG10M time-controlled switch can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising signs, production equipment, radio and television equipment, etc., all circuit equipment and home that need to be turned on and off regularly.
|
|
CHINT/CHINT Terminal Appliance —NH9-32 Disconnector
NH9-32 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage to 400V, rated current 32A circuit, mainly used for on-off resistive loads, including appropriate overload, for the purpose of isolating the line from the power supply. The switch can carry the current under normal circuit conditions ...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|