Product Overview
KG10M time-controlled switch can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising sign lights, production equipment, radio and television equipment and all other circuit equipment and household appliances that need to be turned on and off regularly.
This product has a time automatic calibration function, and the current time can be calibrated in weeks for ± 30s.
Main parameters and technical performance
Rated control power supply voltage: AC220V, 50Hz
Allowable fluctuation range of rated control supply voltage: 85%-110%
Internal power supply: Rechargeable battery, no need to replace
How it works. : Manual on, manual off, automatic on/off
Programmable number: 16 groups
Time control range: 1min - 168h
Timing error: ±2s/d
Output: 1 NO contact
Contact Capacity: Ue/le: AC-15 220V/3A; Ith:10A
Electrical life: 1x 10ⁿ
Mechanical life: 1x10ⁿ
Ambient temperature: -5°C - +40°C
Power consumption: ≤4VA
Installation: Panel type, guide rail type (need to be equipped with CZS08C base)
This article introduces the CHINT/CHINT relay KG10M time control switch products, if you are interested in CHINT/CHINT, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!
|
More on that
|
CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm
Introduction: NJMC1 pulse relay meets the requirements of GB/T 21711.1 standard; The NJMC1 pulse relay is a mechanical bistable relay that changes the state of the contact by inputting a pulse signal. Therefore, compared with ordinary relays, which have to be continuously energized when the armature is closed, pulse relay appliances ...
|
|
CHINT/CHINT Terminal Appliances NX2 Series Distribution Box
NX2 series surface-mounted plastic distribution box (box) (hereinafter referred to as the box) is suitable for AC 50/60Hz, rated voltage 230V/400V, load current does not exceed 100A single-phase three-wire terminal circuit, as a power distribution and control of electrical equipment, but also for the overload of the line, short ...
|
|
CHINT/CHINT Level Relay NJYW1 Series Control electrode voltage 24V
Introduction: NJYW1 series liquid level relay is suitable for automatic control of liquid level in civil water towers, high-level water tanks, underground reservoirs and other occasions in the control circuit of AC 50Hz and rated control power supply voltage to 380V. Automatic water supply or drainage control can be realized according to the user's wiring requirements. Unwell...
|
|
CHINT/CHINT Time Relay JSS48B Delay 1 Conversion
Introduction: JSS48B series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a delay element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT NJYW1 series liquid level relay
Product Overview
NJYW1 series liquid level relay is suitable for automatic control of liquid level in civil water towers, high-level water tanks, underground reservoirs and other occasions in the control circuit of AC 50Hz and rated control power supply voltage to 380V. Automatic water supply or drainage control can be realized according to the user's wiring requirements.
...
|
|
CHINT/CHINT Terminal Appliances — Terminal Box — NX30H Series Distribution Box
NX30H series open/concealed distribution box (box) (hereinafter referred to as distribution box box) is an empty housing before installing 9mm modular terminal electrical components, suitable for circuits with rated voltage of 230V/400V and rated current to 100A. The installation mode of the distribution box box has two ...
|
|
CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ
Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection.
...
|
|
CHINT/CHINT Terminal Appliances —NXU-II. Surge Protective Devices
CHINT/CHINT Terminal Appliances —NXU-II. Surge Protector Main functions: lightning protection and surge protection in the inlet cabinet
Conform to the standard: GB/T18802.1
Basic parameters and technical performance indicators (Table 1)
Choose the appropriate specifications according to different grounding systems and protection modes. °L-PE/N-PE ...
|
|
CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz
NKG3 series time-controlled switch is mainly used as a time control component in the circuit of AC 50Hz and rated control power supply voltage to 220V and below, which is used to turn on or off the circuit according to the predetermined program, and is used for timing on or off control of street lights, advertising light boxes and other equipment.
The main technology ...
|
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|
CHINT/CHINT Thermal Overload Relay NR4 Series Rated current 1.1A
Introduction: NR4 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, rated voltage 690V, 1000V, current (0.1-180)A long-term work or intermittent long-term work of AC motor overload and phase failure protection. This product complies with GB14048.4 ...
|
|
CHINT/CHINT Relay NKG1 Time Control Switch AC220V, 50Hz
The NKG1 time-controlled switch is a control element of the time control unit, which can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising sign lights, production equipment, radio and television equipment, etc., all of which need to be turned on regularly.
|
|
CHINT/CHINT NJG1 series solid state relays
Product Overview
NJG1 series solid state relay adopts photoelectric isolation between input and output, unidirectional thyristor reverse parallel output, zero-crossing conduction, built-in RC absorption loop, MOV protection, epoxy resin glue. Widely used in electric furnace heating constant temperature system, CNC machinery, plastic machinery, food machine ...
|
|
CHINT/CHINT electromagnetic relay JQX-13F switching current 10A
Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Small Electromagnetic Relay NXJ Series Switching voltage 50VAC
Introduction: NXJ series miniature electromagnetic relay 2Z, 3Z, 4Z, 2ZH four contact forms: AC/DC specifications are complete; High contact reliability, can be used for PLC control; Transparent dust cover encapsulation; Equipped with matching sockets; Optionally available with status indicator.
...
|
|
CHINT/CHINT Motor Control & Protection Appliance -JRS1 Series Thermal Overload Relay
JRS1 series thermal overload relay (hereinafter referred to as thermal relay) is mainly used for AC 50Hz/60Hz, voltage to 690V, current (0.1-80)A long-term work or intermittent long-term work AC motor overload and phase failure protection.
The thermal relay has phase failure protection, temperature compensation, dynamic ...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker
NBH8-40 □ household circuit breaker is mainly used for AC 50Hz, rated voltage to 230V, rated current to 40A line as overload and short circuit protection of power lines, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances.
Standard: GB/T 10963 ...
|
|
CHINT/CHINT Level Relay JYB-714 Series Wire length 1km
Introduction: JYB-714 series liquid level relay is suitable for automatic control circuit of liquid level with AC 50Hz and rated control power supply of 380V and below, and is used for automatic level control of civil water towers, high-level water tanks, underground reservoirs and other occasions.
...
|
|
CHINT/CHINT Relay NJX-13FW Size: 27.9x21.9x35.5mm
Introduction: NJX-13FW relay 2Z, 2ZS, 3ZS, 4ZS four contact forms: no oxidation, zero arcing, long life; The transparent cover is sealed and sealed, waterproof, dustproof and anti-corrosion, and can be used in harsh environments such as low air pressure; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available.
|
|