CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ

Create Date: 2024-8-30 12:03:23|Source: CHINT/CHINT

  • Brand:
    CHINT/CHINT
    Origin:
    chekiang
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    NJB1-YW
    Product Introduction
    CHINT/CHINT level relay NJB1-YW works continuously, 1 set of conversion contacts, the voltage between the electrodes is DC12V, the power consumption is about 3VA, and the reset resistance is 250kΩmax
Product Description
Introduction: NJB1-YW liquid level relay is suitable for automatic water level control in industrial facilities and equipment, civil water towers, high-level water tanks, underground reservoirs and other occasions. This product is not suitable for level control of flammable and explosive liquids such as oil, chemical liquids, etc.

                               CHINT/CHINTNJB1-YW

Product parameters

Working mode: continuous work

Number of contacts: 1 set of changeover contacts

Contact capacity: Ue/le: AC- 15 240V/0.75A, 415V/0.47A; Ith: 3A

Rated control power supply voltage: AC36V, AC110V, AC220V, AC380V, 50Hz

Allowable fluctuation range of rated control power supply voltage: 85%-110%

Voltage between electrodes: DC12V

Power consumption: up to approx. 3VA

Operating resistance: 5kΩ2 - 100kΩ (adjustable)

Reset resistance: 250kΩmax

Response time: 0.1s - 10s (adjustable)

Cable length: up to 100m, fully insulated (600V) cable, 3 cores

Indication mode: Green LED: power indication; Red LED: Control output indication

Ambient temperature: -5°C - +40°C

Installation: device type or guide rail type

This article introduces CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ products, if you are interested in CHINT/CHINT Level Relay, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!

More on that
CHINT/CHINT Thermal Overload Relay NXR Series Auxiliary Contacts 1NO+1NC CHINT/CHINT Thermal Overload Relay NXR Series Auxiliary Contacts 1NO+1NC

Introduction: NXR series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, setting current 0.1-630A long-term work or intermittent work of AC motor overload and phase failure protection. Thermal relays also feature temperature compensation, action indication ...

CHINT/CHINT NXMLE series residual current action circuit breaker CHINT/CHINT NXMLE series residual current action circuit breaker

The main function of the residual current action circuit breaker series is to provide indirect contact protection against personal electric shock with fatal danger, and to provide protection against electrical fire caused by ground fault current, such as insulation damage. It also provides protection against overload, short circuit and undervoltage of the line, and can also be used as a ...

CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220 CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220

Product Overview The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state. NJG2 solid state relay is widely used in electric furnace heating...

CHINT/CHINT Level Relay JYB-714 Series Wire length 1km CHINT/CHINT Level Relay JYB-714 Series Wire length 1km

Introduction: JYB-714 series liquid level relay is suitable for automatic control circuit of liquid level with AC 50Hz and rated control power supply of 380V and below, and is used for automatic level control of civil water towers, high-level water tanks, underground reservoirs and other occasions. ...

CHINT/CHINT JZ7 series intermediate relay CHINT/CHINT JZ7 series intermediate relay

JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in the control circuit of AC 50Hz (can be used for 60Hz after derivation), rated working voltage to 380V or DC rated working voltage to 220V, used to control various electromagnetic coils, so as to expand the signal or transmit the signal to the ...

CHINT/CHINT JZC4 series contactor relay CHINT/CHINT JZC4 series contactor relay

JZC4 series contactor relay is mainly used in relay control, signal transmission, isolation amplification and other circuits with AC 50Hz or 60Hz, rated working voltage to 400V and DC rated voltage to 220V, for switching, breaking and amplifying. Standards: GB/T 14048.5, IEC 6 ...

CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ

Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection. ...

CHINT/CHINT Small Electromagnetic Relay NXJ Series Switching voltage 50VAC CHINT/CHINT Small Electromagnetic Relay NXJ Series Switching voltage 50VAC

Introduction: NXJ series miniature electromagnetic relay 2Z, 3Z, 4Z, 2ZH four contact forms: AC/DC specifications are complete; High contact reliability, can be used for PLC control; Transparent dust cover encapsulation; Equipped with matching sockets; Optionally available with status indicator. ...

CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220 CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220

Product Overview The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state. NJG2 solid state relay is widely used in electric furnace heating...

CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz

NKG3 series time-controlled switch is mainly used as a time control component in the circuit of AC 50Hz and rated control power supply voltage to 220V and below, which is used to turn on or off the circuit according to the predetermined program, and is used for timing on or off control of street lights, advertising light boxes and other equipment. The main technology ...

CHINT/CHINT Terminal Appliances — NH4-125 Disconnector CHINT/CHINT Terminal Appliances — NH4-125 Disconnector

NH4-125 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated current to 125A, rated voltage to 400V in the power distribution and control circuit, mainly as the main switch in the terminal combination electrical appliances, can also be used for infrequent control of various low-power electrical appliances and lighting, widely used in ...

CHINT/CHINT Terminal Appliances NX2 Series Distribution Box CHINT/CHINT Terminal Appliances NX2 Series Distribution Box

NX2 series surface-mounted plastic distribution box (box) (hereinafter referred to as the box) is suitable for AC 50/60Hz, rated voltage 230V/400V, load current does not exceed 100A single-phase three-wire terminal circuit, as a power distribution and control of electrical equipment, but also for the overload of the line, short ...

CHINT/CHINT CJ40 Series AC Contactor CJ40-250 CHINT/CHINT CJ40 Series AC Contactor CJ40-250

CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT Relay KG316T Time Control Switch CHINT/CHINT Relay KG316T Time Control Switch

Product Overview KG316T series time-controlled switch is mainly used in the automatic control circuit of AC 50Hz, rated control power supply voltage to 220V, rated working current to 3A, as a regular switching on and off control of street lights, advertising light boxes and other equipment. Technical data KG31 6T Rated...

CHINT/CHINT Motor Control & Protection Appliance -JR36 Series Thermal Overload Relay CHINT/CHINT Motor Control & Protection Appliance -JR36 Series Thermal Overload Relay

JR36 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current 0.25-160A long-term work or intermittent long-term work of AC motor overload and phase failure protection. Thermal relays have phase failure protection, temperature compensation, self-...

CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm

Introduction: NJMC1 pulse relay meets the requirements of GB/T 21711.1 standard; The NJMC1 pulse relay is a mechanical bistable relay that changes the state of the contact by inputting a pulse signal. Therefore, compared with ordinary relays, which have to be continuously energized when the armature is closed, pulse relay appliances ...

CHINT/CHINT Terminal Appliance —NH9-32 Disconnector CHINT/CHINT Terminal Appliance —NH9-32 Disconnector

NH9-32 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage to 400V, rated current 32A circuit, mainly used for on-off resistive loads, including appropriate overload, for the purpose of isolating the line from the power supply. The switch can carry the current under normal circuit conditions ...

CHINT/CHINT Motor Control & Protection Appliance -NR2 Series Thermal Relay CHINT/CHINT Motor Control & Protection Appliance -NR2 Series Thermal Relay

NR2 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current (0.1-150)A long-term work or intermittent long-term operation of AC motor overload and phase failure protection. The thermal relay also features temperature compensation, action indication, ...

CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper

Rated insulation voltage (Ui): 500V; Rated operating current at different rated operating voltages (see Table 1) Usage Category: AC-12, DC-12 Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...

CHINT/CHINT NR5 series thermal overload relays CHINT/CHINT NR5 series thermal overload relays

NR5 series thermal overload relay is suitable for AC 50Hz (or 60Hz), rated working voltage to 690V, working current 0.1-630A long-term work or intermittent long-term work of AC motor overload and phase failure protection, but also has temperature compensation, action indication, automatic ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top