CHINT/CHINT Terminal Appliances — NH4-125 Disconnector

Create Date: 2024-8-30 12:03:23|Source: CHINT/CHINT

  • Brand:
    CHINT/CHINT
    Origin:
    chekiang
    Price:
    Please contact customer service
    Delivery time:
    Please contact customer service
    Model:
    NH4-125
    Product Introduction
    It is mainly used as the main switch in the terminal combination electrical appliances, and can also be used to control all kinds of low-power electrical appliances and lighting infrequently, and is widely used in industrial and mining enterprises, high-rise buildings, commercial and home and other places.
Product Description
NH4-125 isolation switch (hereinafter referred to as the switch) is suitable for AC 50Hz, rated current to 125A, rated voltage to 400V in the power distribution and control circuit, mainly as the terminal combined electrical appliances in the main switch, can also be used for infrequent control of all kinds of low-power electrical appliances and lighting, widely used in industrial and mining enterprises, high-rise buildings, commercial and family and other places.
CHINT/CHINT Terminal Appliances — NH4-125 Disconnector
Comply with standards: GB/T 14048.3, IEC60947-3, and obtain CCC, CE, SEMKO, EAC, Ukraine, VDE, SAA certification.

classify

According to the rated current, it is divided into: 32A, 63A, 100A, 125A.

According to the number of poles, it is divided into: 1P, 2P, 3P, 4P;

Main technical parameters:

Rated insulation voltage Ui : AC 400V

Rated operating voltage Ue : 230V AC (1P), 400V AC (2P, 3P, 4P)

Rated working current: 32A, 63A, 100A, 125A.

Rated impulse withstand voltage Uimp : 4kV(2000m) ;

Rated short-time withstand current Icw: 12le, power-on time 1s;

Rated switching and breaking capacity: 3le, 1.05Ue, cos=0.65;

Rated short-circuit turn-on capacity Icm: 20le, power-on time 0.1s;

Mechanical and electrical life: mechanical life 8500 times, electrical life 1500 times.

Selection of installed copper conductors (see Table 1)

Rated operating current Ie(A)Nominal cross-sectional area of copper conductor (mm)
326
6316
10035
12550
This article introduces CHINT/CHINT terminal appliances - NH4-125 disconnector products interested, also contact our customer service, we look forward to your call, hope our technology and service can bring you a better experience.

The company has been customer-centric, the concept of creating value for customers, winning the market with quality and service, and sincerely hopes to cooperate with all sectors of society to create success, create brilliance together, and work together to create a better tomorrow! In line with the concept of credibility and service-oriented, the company warmly welcomes new and old customers to inquire, visit and negotiate business!

More on that
CHINT/CHINT Terminal Appliance —NH9-32 Disconnector CHINT/CHINT Terminal Appliance —NH9-32 Disconnector

NH9-32 disconnector (hereinafter referred to as the switch) is suitable for AC 50Hz, rated voltage to 400V, rated current 32A circuit, mainly used for on-off resistive loads, including appropriate overload, for the purpose of isolating the line from the power supply. The switch can carry the current under normal circuit conditions ...

CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz CHINT/CHINT NKG3 Time Control Switch AC220V, 50Hz

NKG3 series time-controlled switch is mainly used as a time control component in the circuit of AC 50Hz and rated control power supply voltage to 220V and below, which is used to turn on or off the circuit according to the predetermined program, and is used for timing on or off control of street lights, advertising light boxes and other equipment. The main technology ...

CHINT/CHINT Terminal Appliances —NXU-II. Surge Protective Devices CHINT/CHINT Terminal Appliances —NXU-II. Surge Protective Devices

CHINT/CHINT Terminal Appliances —NXU-II. Surge Protector Main functions: lightning protection and surge protection in the inlet cabinet Conform to the standard: GB/T18802.1 Basic parameters and technical performance indicators (Table 1) Choose the appropriate specifications according to different grounding systems and protection modes. °L-PE/N-PE ...

CHINT/CHINT Small Electromagnetic Relay NJX3 has a rated voltage of 24VAC CHINT/CHINT Small Electromagnetic Relay NJX3 has a rated voltage of 24VAC

Introduction: CHINT/CHINT miniature electromagnetic relay NJX3 has three contact forms: 1Z, 2Z and 3Z; Small structure, low power consumption, strong carrying capacity and high reliability; Widely used in the HVAC industry, it is used to control condensers, compressors, air conditioners and other equipment, and is the basic element in the air conditioning industry.

CHINT/CHINT Time Relay NTE8 Series Reset time ≤1s CHINT/CHINT Time Relay NTE8 Series Reset time ≤1s

Introduction: NTE8 series time relay is mainly used as a time control component in the control circuit of AC 50Hz, rated control power supply voltage to 415V and DC rated control power supply voltage to 24V, and the circuit is turned on or off at a predetermined time. ...

CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker CHINT/CHINT Terminal Appliance —NBH8-40□ Household Circuit Breaker

NBH8-40 □ household circuit breaker is mainly used for AC 50Hz, rated voltage to 230V, rated current to 40A line as overload and short circuit protection of power lines, and can also be used for infrequent switching of electrical devices and power lines under normal circumstances. Standard: GB/T 10963 ...

CHINT/CHINT Solid State Relay NJG1 Series Load power factor 0.5 CHINT/CHINT Solid State Relay NJG1 Series Load power factor 0.5

Introduction: NJG1 series solid state relay adopts photoelectric isolation between input and output, one-way thyristor reverse parallel output, zero-crossing conduction, built-in RC absorption loop, MOV protection, epoxy resin potting. Widely used in electric furnace heating constant temperature system, CNC machinery, plastic machinery, food machinery, ...

CHINT/CHINT electromagnetic relay JQX-13F switching current 10A CHINT/CHINT electromagnetic relay JQX-13F switching current 10A

Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator. Give birth...

CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ

Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection. ...

CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220 CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220

Product Overview The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state. NJG2 solid state relay is widely used in electric furnace heating...

CHINT/CHINT CJ40 Series AC Contactor CJ40-250 CHINT/CHINT CJ40 Series AC Contactor CJ40-250

CJ40 series AC contactor (hereinafter referred to as contactor) is mainly used for switching and breaking circuits in power systems with AC 50Hz or 60Hz, rated voltage to 660V or 1140V, and current to 1000A.

CHINT/CHINT Level Relay JYB-714 Series Wire length 1km CHINT/CHINT Level Relay JYB-714 Series Wire length 1km

Introduction: JYB-714 series liquid level relay is suitable for automatic control circuit of liquid level with AC 50Hz and rated control power supply of 380V and below, and is used for automatic level control of civil water towers, high-level water tanks, underground reservoirs and other occasions. ...

CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ

Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator. Give birth...

CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220 CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 15A220

Product Overview The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state. NJG2 solid state relay is widely used in electric furnace heating...

CHINT/CHINT Time Relay JSS48B Delay 1 Conversion CHINT/CHINT Time Relay JSS48B Delay 1 Conversion

Introduction: JSS48B series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a delay element, according to the predetermined time to turn on or off the circuit. ...

CHINT/CHINT Electromagnetic Relay JZX-22F Small Medium Power 250VAC CHINT/CHINT Electromagnetic Relay JZX-22F Small Medium Power 250VAC

Introduction: JZX-22F small medium power electromagnetic relay 2Z, 3Z, 4Z three contact forms; AC/DC specifications are complete, and the installation methods are diverse; A variety of sockets are available, and there are specifications with indicator lights; Similar models: HH52P(-L), MY2(N), JZX-18F(L), HH53P...

CHINT/CHINT Motor Control & Protection Appliance -NR2 Series Thermal Relay CHINT/CHINT Motor Control & Protection Appliance -NR2 Series Thermal Relay

NR2 series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, current (0.1-150)A long-term work or intermittent long-term operation of AC motor overload and phase failure protection. The thermal relay also features temperature compensation, action indication, ...

CHINT/CHINT electromagnetic relay JQX-10F size 35x35x53mm CHINT/CHINT electromagnetic relay JQX-10F size 35x35x53mm

Introduction: JQX-10F small electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; It has a working status indication device; A variety of device sockets are available. Product parameters ...

CHINT/CHINT Time Relay JSS48A Series Time Delay Accuracy≤1% CHINT/CHINT Time Relay JSS48A Series Time Delay Accuracy≤1%

Introduction: JSS48A series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a time control element, according to the predetermined time to turn on or off the circuit. ...

CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ

Introduction: NJB1-YW liquid level relay is suitable for automatic water level control in industrial facilities and equipment, civil water towers, high-level water tanks, underground reservoirs and other occasions. This product is not suitable for level control of flammable and explosive liquids such as oil, chemical liquids, etc. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top