Introduction: NJX2 miniature electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; A variety of device sockets are available; It has mechanical locking, power-on indication and mechanical indication functions for selection.
Product parameters
Contact type: 2Z(C), 3Z(C)
Contact resistance: 100mQ
Contact Material: Silver Alloy
Contact load (resistive): 10A 250VAC/30VDC
Maximum switching voltage: 250VAC/30VDC
Maximum switching current: 10A
Maximum switching power: 2500VA 300W
Electrical Life (Times): 1x10'
Mechanical Life (Times): 1x10'
Insulation Resistance: 100MQ (500VDC)
The medium is pressure-resistant
Between coil contacts, between heterogeneous contacts: 1 500VAC
Between disconnect contacts: 500VAC
Operating time (25°C, rated voltage): ≤20ms
Release time (25°C, rated voltage): S 20ms
Shock (stability): Acceleration 100m/s', pulse duration 11ms
Vibration. : Double amplitude 1mm, (10-55) Hz
Lead-out form: cast-and-pull
Dimensions(mm)
35>35<53 (Standard)
35x35x55 (with mechanical latching)
The company respects the enterprise spirit of "practicality, hard work and responsibility", and creates a good corporate environment with integrity, win-win, and business philosophy, and takes a new management model, perfect technology, thoughtful service, and excellent quality as the foundation for survival. We always adhere to: customer first, serve customers attentively, and insist on impressing customers with their own services. Always adhering to the business philosophy of "integrity, win-win", relying on excellent prices, excellent quality, fast delivery and pre-sales consultation and after-sales service to win the trust of our customers.
This article introduces CHINT/CHINT Small Electromagnetic Relay NJX2 Contact Resistance 100mQ products, if you are interested in CHINT/CHINT Relay, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
CHINT/CHINT Terminal Appliance SHT-X1 Deciter Tripper
Rated insulation voltage (Ui): 500V;
Rated operating current at different rated operating voltages (see Table 1)
Usage Category: AC-12, DC-12
Action characteristics: At 70%-10% of the rated control power supply voltage, the tripper should act reliably to disconnect the circuit breaker. Tripper ...
|
|
CHINT/CHINT electromagnetic relay JQX-10F size 35x35x53mm
Introduction: JQX-10F small electromagnetic relay 2Z, 3Z two contact forms; Contact switching current up to 10A; AC and DC specifications are complete; It has a working status indication device; A variety of device sockets are available.
Product parameters
...
|
|
CHINT/CHINT Thermal Overload Relay NXR Series Auxiliary Contacts 1NO+1NC
Introduction: NXR series thermal overload relay (hereinafter referred to as thermal relay) is suitable for AC 50Hz/60Hz, voltage to 690V, setting current 0.1-630A long-term work or intermittent work of AC motor overload and phase failure protection. Thermal relays also feature temperature compensation, action indication ...
|
|
CHINT/CHINT NJG2 Series Solid State Relay NJG2- SDA032- 10A220
Product Overview
The NJG2 Solid State Relay is a switching device that replaces contact with a semiconductor device. The input and output are photoelectically isolated, and when a control signal is added to the input, the output can be converted from a broken state to a connected state.
NJG2 solid state relay is widely used in electric furnace heating...
|
|
CHINT/CHINT electromagnetic relay JQX-13FA contact resistance 100mΩ
Introduction: JQX-13FA small high-power electromagnetic relay 20A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Level Relay NJB1-YW Reset Resistance 250kΩ
Introduction: NJB1-YW liquid level relay is suitable for automatic water level control in industrial facilities and equipment, civil water towers, high-level water tanks, underground reservoirs and other occasions. This product is not suitable for level control of flammable and explosive liquids such as oil, chemical liquids, etc.
...
|
|
CHINT/CHINT Terminal Appliances NX2 Series Distribution Box
NX2 series surface-mounted plastic distribution box (box) (hereinafter referred to as the box) is suitable for AC 50/60Hz, rated voltage 230V/400V, load current does not exceed 100A single-phase three-wire terminal circuit, as a power distribution and control of electrical equipment, but also for the overload of the line, short ...
|
|
CHINT/CHINT NJG1 series solid state relays
Product Overview
NJG1 series solid state relay adopts photoelectric isolation between input and output, unidirectional thyristor reverse parallel output, zero-crossing conduction, built-in RC absorption loop, MOV protection, epoxy resin glue. Widely used in electric furnace heating constant temperature system, CNC machinery, plastic machinery, food machine ...
|
|
CHINT/CHINT Terminal Appliance —NH8-125 Disconnector
NH8-125 isolating switch is mainly suitable for AC 50Hz, rated voltage to 415V, rated current 125A and below in the power distribution and control circuit, mainly as the terminal combination electrical appliances in the main switch, can also be used for infrequent control of all kinds of low-power electrical appliances and lighting, widely used in industrial and mining enterprises ...
|
|
CHINT/CHINT Level Relay JYB-714 Series Wire length 1km
Introduction: JYB-714 series liquid level relay is suitable for automatic control circuit of liquid level with AC 50Hz and rated control power supply of 380V and below, and is used for automatic level control of civil water towers, high-level water tanks, underground reservoirs and other occasions.
...
|
|
CHINT/CHINT Time Relay JSS48B Delay 1 Conversion
Introduction: JSS48B series time relay is suitable for AC 50Hz, rated control power supply voltage to 380V and DC rated control power supply voltage to 240V as a delay element, according to the predetermined time to turn on or off the circuit.
...
|
|
CHINT/CHINT JZ7 series intermediate relay
JZ7 series intermediate relay (hereinafter referred to as the relay) is mainly used in the control circuit of AC 50Hz (can be used for 60Hz after derivation), rated working voltage to 380V or DC rated working voltage to 220V, used to control various electromagnetic coils, so as to expand the signal or transmit the signal to the ...
|
|
CHINT/CHINT Pulse Relay NJMC1 size 86x 70x18mm
Introduction: NJMC1 pulse relay meets the requirements of GB/T 21711.1 standard; The NJMC1 pulse relay is a mechanical bistable relay that changes the state of the contact by inputting a pulse signal. Therefore, compared with ordinary relays, which have to be continuously energized when the armature is closed, pulse relay appliances ...
|
|
CHINT/CHINT Motor Control & Protection Appliances - NRE8 Series Electronic Overload Relay
NRE8 series electronic overload relay (hereinafter referred to as the relay) is mainly used in the circuit with AC 50/60Hz, rated working voltage below 690V, and the current is within the range of the setting current calibrated by the casing, for three-phase motor overload and phase failure protection.
This relay is an application microcontroller ...
|
|
CHINT NJA1-KG Relay (Intelligent Time Control Switch)
NJA1-KG relay is mainly used as a timing (alarm clock), switch-on or off-control in the control circuit with AC frequency of 50Hz, rated control power supply voltage to 240V and DC rated control power supply voltage to 240V.
|
|
CHINT/CHINT Relay NKG1 Time Control Switch AC220V, 50Hz
The NKG1 time-controlled switch is a control element of the time control unit, which can automatically turn on and off the power of various electrical equipment according to the time set by the user. The control object can be street lights, neon lights, advertising sign lights, production equipment, radio and television equipment, etc., all of which need to be turned on regularly.
|
|
CHINT/CHINT NXMLE series residual current action circuit breaker
The main function of the residual current action circuit breaker series is to provide indirect contact protection against personal electric shock with fatal danger, and to provide protection against electrical fire caused by ground fault current, such as insulation damage. It also provides protection against overload, short circuit and undervoltage of the line, and can also be used as a ...
|
|
CHINT/CHINT Relay Time Control Switch NJA1-L Relay (Intelligent Logic Controller)
NJA1-L relay is mainly used as a logic control element in the control circuit with AC frequency of 50Hz/60Hz, rated control power supply voltage to 240V and DC rated control power supply voltage to 240V or less, and performs relevant actions according to the set program.
Technical parameters: NJA1-L
Forehead...
|
|
CHINT/CHINT electromagnetic relay JQX-13F switching current 10A
Introduction: JQX-13F small high-power electromagnetic relay 10A contact switching capability; AC/DC specifications are complete; Transparent dust cover encapsulation, various installation methods; A variety of sockets are available; Optionally available with status indicator.
Give birth...
|
|
CHINT/CHINT Relay KG316T Time Control Switch
Product Overview
KG316T series time-controlled switch is mainly used in the automatic control circuit of AC 50Hz, rated control power supply voltage to 220V, rated working current to 3A, as a regular switching on and off control of street lights, advertising light boxes and other equipment.
Technical data KG31 6T