Introduction: Rorobot BMC-4H18[H]/S
Features:
The fingertips are open in the positive pressure state, clamped in the negative pressure state, and it is recommended to use it with a soft-touch air drive, and the working air pressure can be adjusted by using the external support fingertip distance D.
When the workpiece is light in weight, or very soft, and it is easy to adhere to and adsorb on the soft claw when blanking, the non-marking material [HAS] should be preferred.
There is a small hook at the bottom of the leg, which can hold the workpiece from the bottom when supporting the annular workpiece inside, so that the workpiece is not easy to slip off, so as to achieve high-speed and stable handling effect.
Product parameters
Recommended load: 15g
Service life: 1,500,000 times
Safe working air pressure: 150kPa
Opening and closing frequency: 6 times/second
Internal support clamping force: 0-0.15N
BMC module weight: 13g
BML module weight: 22g
Our customer-centric service concept: the pursuit of a full range of services is a high-quality, high-standard service, the pursuit of every detail of the service process. It is impossible for interests to blossom into brilliant flowers from lies. Only every process, every action, and every detail of the service can be professional and careful, in order to meet or even exceed customer expectations, so that customers are satisfied and recognize us. Honest, professional, affordable, fast, so let you rest assured." Integrity and professional service, affordable price, and continuous improvement" is our service concept.
This article introduces the BMC-4H18[H]/S products of Rorobot Soft Touch, if you are interested in Rorobot Soft Touch, please also contact our customer service, we are looking forward to your call, hope our technology and service can bring you a better experience.
|
More on that
|
Rorobot B-4H18[H]/S The recommended load is 15g
Introduction: Rorobot B-4H18[H]/S
Features:
The fingertips are open in the positive pressure state, clamped in the negative pressure state, and it is recommended to use it with a soft-touch air drive, and the working air pressure can be adjusted by using the external support fingertip distance D.
The soft claw material is divided into conventional type [H] and non-marking type [ ...
|
|
Soft Touch/Rorobot Finger Module B3V4 Positive pressure stroke 9mm
Introduction: Soft Touch/Rorobot Finger Module B3V4, Features and Applicable Scenarios: Large clamping force, can be used in series (using screw accessory kit PK) and simplifies the trachea arrangement. It is mostly used in the scene where multiple fingers work at the same time and the workpiece is compact, and the workpiece width is generally greater than 50mm.
Product Features ...
|
|
Soft Touch/Rorobot Soft Jaw BMC-3G20[H]/S
Introduction: Rorobot BMC-3G20[H]/S
Features:
The fingertip is open in the positive pressure state, and the vacuum state is clamped, and it is recommended to use it with a soft-touch air driver, and the working air pressure can be adjusted by supporting the fingertip distance G.
Soft-touch materials are divided into conventional type [H] and non-marking ...
|
|
Soft Touch/Rorobot Finger F-C5 Fingertip Travel 27mm
Introduction: Soft Touch/Rorobot Finger F-C5
Features:
The finger material can be selected as regular type, reinforced type [H] and anti-static type [AS].
The reinforced grade [H] has a higher operating pressure range and a gripping force of up to 300% of the fingers of conventional grades.
Defend...
|
|
Soft Touch/Rorobot Driver LCH-U Positive Pressure Flow Rate 165L/min
Introduction: Soft-Touch/Rorobot Actuator LCH-U is a lightweight actuator designed for soft-touch grippers with both positive pressure and vacuum output, and can be used for both multi-channel and asynchronous drives
Product parameters
Enter the air supply
0.4—0.6MPa
Flow rate> 200L/min
Lose...
|
|
Soft Touch/Rorobot Finger F-C7 Negative pressure stroke 29mm
Introduction: Soft Touch/Rorobot Finger F-C7
Features:
The finger material can be selected as regular type, reinforced type [H] and anti-static type [AS].
The reinforced grade [H] has a higher operating pressure range and a gripping force of up to 300% of the fingers of conventional grades.
Defend...
|
|
Soft-Touch/Rorobot Slip Mounting Plate SMP-4L slot width 4.2mm
Introduction: Soft-Touch/Rorobot Skid Shift Mounting Plate SMP-4L
Features:
It is divided into different styles according to the shape and length of the groove
It can be used for assembly between the finger module [FM] and the flange connection module [FCM].
The mounting angle and position of the finger module [FM] can be adjusted freely
...
|
|
Rorobot BMC-4B32[HAS]/S
Introduction: Rorobot Robot BMC-4B32[HAS]/S
Features:
The fingertips are open in the positive pressure state, and the clamping is in the vacuum state, and it is recommended to use the soft-touch air drive, and the working air pressure can be adjusted by clamping the fingertips G and the outer support fingertips D.
Soft claws ...
|
|
Soft Touch/Rorobot Gripper BOM
Introduction: SoftTouch/Rorobot Gripper BOM
Product parameters
Skid Mounting Plate: SMP-02
Profile: P-20300
Connector: CP-04
Flange connection module: FCM-R06
Our customer-centric service concept: a full range of services to pursue ...
|
|
Soft Touch/Rorobot Finger F-C4 Negative Pressure Stroke 9mm
Introduction: Soft Touch/Rorobot Finger F-C4
Features:
The finger material can be selected as regular type, reinforced type [H] and anti-static type [AS].
The reinforced grade [H] has a higher operating pressure range and a gripping force of up to 300% of the fingers of conventional grades.
Defend...
|
|
Soft Touch/Rorobot Finger Module FM-A6V2 Finger length 83mm
Introduction: Rorobot Finger Module FM-A6V2, Features and Applicable Scenarios: Independent Installation, Can be Installed with SMP Sliding Mounting Plate, Finger Spacing and Angle Adjustable, Fixation Method: Can Be Fixed from Four Directions (Optional), Air Intake Mode: Air Intake Connector Can Be Installed from Three Directions (Optional)
...
|
|
Soft Touch/Rorobot Finger Module A3V4 Finger height 28mm
Introduction: Rorobot Finger Module A3V4, Features and Applicable Scenarios: Large clamping force, can be used in series (using screw accessory kit PK) and simplifies the arrangement of the trachea. It is mostly used in the scene where multiple fingers work at the same time and the workpiece is compact, and the workpiece width is generally greater than 50mm.
Product Features ...
|
|
Rorobot BMC-1G364030[H]/M The recommended load is 500g
Introduction:Rorobot Soft Jaw BMC-1G364030[H]/M, is a strengthened version of the single finger soft jaw, the recommended distance between the fingertip and the workpiece is (19-28) mm, the recommended load of the single finger soft jaw is (0-500)G, and the external gripping force is (0-11)N.
Features:
Positive pressure state fingertip hit ...
|
|
Soft Touch/Rorobot Soft Jaw BML-4BG64[P]/S Opening and closing frequency 6 times/second
Introduction:Rorobot BML-4BG64/S, B-4BG64/S is an external gripper type soft jaw, the recommended clamping workpiece size is (28-50) mm, the opening and closing size is (50.4-80) mm, suitable for grabbing steamed cakes, buns, siu mai and jujube cakes and other soft foods, B-4BG64/S is ...
|
|
Soft Touch/Rorobot Finger F-C3 Fingertip travel 10.5mm
Introduction: Soft Touch/Rorobot Finger F-C3
Features:
The finger material can be selected as regular type, reinforced type [H] and anti-static type [AS].
The reinforced grade [H] has a higher operating pressure range and a gripping force of up to 300% of the fingers of conventional grades.
Defend...
|
|
Rorobot BMC-1G071010[LP]/S The recommended load is 12g
Introduction: Rorobot Robot Soft Jaw BMC-1G071010[LP]/S
Features:
The fingertip is open in the positive pressure state, and the vacuum state is clamped, and it is recommended to use it with a soft-touch air drive, and the working air pressure can be adjusted for the distance G between the fingertip and the workpiece.
The soft claw material is divided into ...
|
|
Rorobot BML-20606 [PAS] 30g load is recommended
Introduction:Rorobot Soft Jaw BML-20606,
Features:
The fingertips are open in the positive pressure state, and the vacuum state is clamped, so it is recommended to use it with a soft-touch air drive, and the working air pressure can be adjusted by clamping the fingertip distance G
The soft claw material is divided into conventional type and non-marking type, when ...
|
|
Soft Touch/Rorobot Finger Module B4V5 Module length 82mm
Introduction: Rorobot Finger Module B4V5, Features and Applicable Scenarios: The module is thinner and lighter, and the minimum finger spacing of the mounting module is only 10mm, which is suitable for clamping tiny, thin and light workpieces. It can also be used in series (using the screw kit PK), but compared to the V4, each finger needs to be supplied with air independently.
|
|
SoftTouch/Rorobot Finger Module C7V4 Module height 35mm
Introduction: Soft Touch/Rorobot Finger Module C7V4, Features and Applicable Scenarios: Large Clamping Force, Can Be Used in Series (Use Screw Accessory Kit PK) and Simplify the Trachea Arrangement. It is mostly used in scenarios where multiple fingers work at the same time and the workpiece is compact, and the width of the workpiece is generally greater than 50mm
Features:
...
|
|
Soft Touch/Rorobot Finger Module B5V3 Finger width 18mm
Introduction: Rorobot Finger Module B5V3, Features and Applicable Scenarios: Independent installation, can be installed with SMP sliding mounting plate, finger spacing and angle can be adjusted.
Features:
Features and applicable scenarios: independent installation, can be installed with SMP sliding mounting plate, finger spacing and ...
|
|