The Siemens 3RM11/3RM13 motor starters have two different protection functions

Create Date: 2024-8-30 12:03:23|Source: Siemens/Siemens

The 3RM11/3RM13 motor starters include two different protection functions.
The Siemens 3RM11/3RM13 motor starters have two different protection functions

One protection function is a safety application, and the other is an explosion protection application (ATEX).

1. Functional Safety:

Here, the purpose of protection is to identify and control dangerous conditions. In terms of safety functions, the 3RM11/3RM13 motor starter acts as an actuator subsystem that monitors its own faults. The architecture of the actuator subsystem can be achieved with HFT=1 (Hardware Fault Margin) and SIL3 according to the IEC62061 standard and PLe and Cat.4 according to ISO 13849-1

2. Explosion Protection (ATEX):

Here, the purpose of protection is to prevent the possibility of a fire in a dangerous area. For the 3RM11/3RM13 motor starters, it can provide overload protection for the motor or transformer. The 3RM11/3RM13 motor starters are available for ATEX Category 2 class. Therefore, the 3RM11/3RM13 overload protection function is single-channel, i.e. HFT=0, and based on the existing diagnostic capabilities, the 3RM11/3RM13 motor starter overload protection function can achieve SIL2

Summary of SIL and PL:

According to the IEC62061 standard, functional safety level = > SIL3, HFT1, SFF > 99%; According to the ISO13849-1 standard, the functional safety level can be achieved up to PLe and Cat.4, and the high index DC ≥ 99

According to the EN50495 standard, explosion protection class (ATEX) = > SIL2, HFT0, ATEX Cat.2
More on that
Overview of the Siemens SINAMICS G120 frequency inverter Overview of the Siemens SINAMICS G120 frequency inverter

Whether pumping, ventilation, compression, movement or process machining: SINAMICS G120 is a universal drive that meets a wide range of requirements. It has clear advantages in general mechanical engineering as well as in the automotive, textile and packaging industries. Its modular design and its range from 0.55 kW to 250 k ...

Can two different FB blocks in OB1 run at the same time in the S7-300PLC? Can two different FB blocks in OB1 run at the same time in the S7-300PLC?

1. It is impossible to be simple at the same time, and at the same time it is relative. The CPU can only run one program at a given time. 2. Understand that S7-300PLC is a cycle scan: ie a. At the beginning of a regular cycle, the CPU performs signals such as input jobs (fill in the input image area data...)

Siemens presents the new Sinamics G220 high-performance inverter Siemens presents the new Sinamics G220 high-performance inverter

On the eve of the Hannover Messe 2023, Siemens launched a new product in the Sinamics series, the Sinamics G220 high-performance frequency inverter. This innovative inverter product uses clean converter technology to reduce harmonics by up to 97% without the need for incoming filters or incoming reactors.   ...

How to erase the password using a memory card How to erase the password using a memory card

If the customer has forgotten the password of the S7-1200 that was previously set, the program and password inside the S7-1200 cannot be erased through "Factory Reset", and the only way to erase the password is to use a memory card. The detailed steps are as follows: Power off the S7-1200 device Insert a ...

What does the fan of the Siemens 3RW soft starter do? What does the fan of the Siemens 3RW soft starter do?

The function of the 3RW soft starter fan is to speed up the heat dissipation, which can effectively improve the operating frequency of the soft starter. 3RW30 soft starter cannot be equipped with a fan. 3RW402-404 Soft Starter Fan is not a standard equipment ...

Siemens and New Hope work together to create new opportunities Siemens and New Hope work together to create new opportunities

At present, digital technology is empowering the transformation and upgrading of traditional agriculture, animal husbandry and food industries. The use of innovative technologies such as artificial intelligence, big data analysis and cloud accounting has brought the modernization and intelligence of industry to a further step.   As a well-known enterprise in China, New Expectation Group Co., Ltd. ( ...

Siemens acquires a minority stake in WiTricity Siemens acquires a minority stake in WiTricity

Siemens invested $25 million to acquire a minority stake in WiTricity, a United States wireless charging technology company. Siemens and WiTricity will work together to promote the innovation of new shopping malls for wireless electric car charging, according to Siemens' calculations, by 2028, only in Europe and North America, which ...

Siemens S7-200 SMART communication protocols and resources Siemens S7-200 SMART communication protocols and resources

Each S7-200 SMART CPU provides an Ethernet port and an RS485 port (port 0), and the standard CPU additionally supports the SB CM01 signal board (port 1), which can be configured as an RS232 communication port or R...

Siemens S7-200 SMART Common questions about serial communication Siemens S7-200 SMART Common questions about serial communication

1.Does the S7-200 SMART support Modbus ASCII communication mode? The STEP 7-Micro/WIN SMART software does not provide a library of Modbus ASCII communication modes. If the S7-200 SMART CPU is used for Modbus ASCII communication, it needs to be used by the user to use the free port communication.

Siemens introduces a new generation of industrial Ethernet switches Siemens introduces a new generation of industrial Ethernet switches

At SPS 2022 in Nuremberg, Siemens introduced the new generation of Scalance XC-/XR-300 series Industrial Ethernet switches. With the increasing number of machines, controls and IT systems connected to the network in industrial production, the network at the production level is also ...

Siemens launches the new SITOP PSU2200 economical rail power supply Siemens launches the new SITOP PSU2200 economical rail power supply

Siemens expands its power supply portfolio with the launch of the new SITOP PSU2200 economical rail power supply. The new product can be divided into three models according to the output current: 3A, 5A and 10A, which can convert AC 220V to DC 24V to meet the fundamental needs of industrial power supply. SITOP PSU2200 ...

The Siemens S7-1200 communicates with the TCP Debugging Assistant The Siemens S7-1200 communicates with the TCP Debugging Assistant

TCP and debug assistant The S7-1200 supports the standard TCP protocol and can communicate with other devices or software as a client and server. By calling TSEND_C, TRCV_C, TCON and other commands, you can communicate with the partner TCP connection is established. Using a network tune on a PC ...

The Mendix low-code development contest is now open The Mendix low-code development contest is now open

Siemens will use Mendix, the industry-leading low-code development channel under Siemens, to meet the practical business needs of enterprises, combine several general scenarios, and deepen the learning of Mendix low-code channels, so that we can understand the essence of the product, stimulate innovation ideas, and open up the road to innovation. ...

The Siemens plant automates the motor industry The Siemens plant automates the motor industry

In recent years, many motor production enterprises have also taken precautions and begun to focus on the intelligent automation of motor production. However, due to the messiness and particularity of the motor production process, in the specific process of motor production, in order to ensure the accuracy of the parts, it is still necessary to rely on traditional manual operation, ...

What is RFC1006 and what does it do? What is RFC1006 and what does it do?

RFCs (Requests for Comments) are technical documents that cover topics such as Ethernet architecture, protocol design, email header design, etc. - Detailed description of RFC 1006 "ISO Transport Service on top of the ...

The Siemens soft starter 3RW44 can self-reset and can fail The Siemens soft starter 3RW44 can self-reset and can fail

Not all faults can achieve self-reset, and the faults that can achieve self-reset are as follows, (the method of self-reset is to set the corresponding parameters in the menu of the LCD display): 1) The motor thermal model is overloaded. The way to achieve self-reset is to select "Settings" -> "Response..." -> "Thermal ...

Siemens S7-1200 CPU motion control and high-speed counter function Siemens S7-1200 CPU motion control and high-speed counter function

1. S7-1200 CPU motion control S7-1200 Body Motion Control Axis Resources: In open-loop control mode, the maximum number of pulse axes is 4 and cannot be expanded. In closed-loop control mode: S7-1200 with firmware version V4.1 and above can be used in ...

Siemens 3RW44 soft start press emergency start why not Siemens 3RW44 soft start press emergency start why not

The 3RW44 has an emergency start function, but why does the soft start not start when the emergency start button is closed? Emergency start refers to the unevenness of the motor; thermal model overload; Open circuit of temperature sensor; Short circuit of the temperature sensor; The temperature sensor is overloaded; Exceeding the maximum starting time; Surpass...

Siemens supports the transition to sustainable infrastructure with new digital solutions Siemens supports the transition to sustainable infrastructure with new digital solutions

Siemens unveiled its face at the 2022 Lighting and Construction Electrical Exhibition in Frankfurt, Germany under the theme of "Smart Infrastructure Can Continue Infrastructure". During the exhibition, Siemens Essentials underlined its digital vision as the infrastructure needed to address climate change and global sustainability challenges.

SIMATIC S7-1200 compact CPU SIMATIC S7-1200 compact CPU

Installation 1. Remove the backplane bus cover 2. Insert the SM onto the standard mounting rail 3. Push the SM to the adjacent module 4. Lock the standard rail mounting clip 5. Push the latch used to connect the bus connector to the left so that the bus pin is connected to the adjacent module ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top