Siemens S7-1200 series frequently asked questions about formulation functions
1.Do all CPUs in the S7-1200 series support recipe functions?
The CPU version of the S7-1200 is V4.0 or later, and recipe function instructions are supported.
HOWEVER, THE FUNCTION OF THE FORMULA IN A BROAD SENSE, FROM THE TIA PORTAL V11 SP2, S7-1200 V2.0 FIRMWARE VERSION ...
|
|
What cable lengths are available between the motor and the soft starters 3RW22, 3RW30, 3RW31, 3RW34, 3RW40, 3RW44
3RW22 (no longer available):
With SIKOSTART 3RW22, the maximum permissible cable length between SIKOSTART and the motor is 200m.
3RW30xx-xAAxx 3RW30xx-xABxx, 3RW30xx-xCBxx, 3RW31xx-xCBxx (no longer available):
...
|
|
Siemens 3RV2 circuit breaker application
The 3RV2 circuit breaker is a compact current-limiting motor start-up protection circuit breaker for the opening and closing of three-phase induction motors (up to 55 kW at 400 V AC) and other loads (rated up to 100 A).
The 3RV2 circuit breaker is suitable for any kind of climate ...
|
|
Siemens won the 2021 "Together, Together, Together" award
At the 2021 "Together, Together, Together" award ceremony hosted by the Germany Chamber of Commerce in China, Siemens once again won praise for "leading the way to building a sustainable supply chain". Siemens has previously pledged to reduce emissions in its global supply chain by 20% by 2030 and by 2050 to achieve ...
|
|
Siemens Electric Products China Headquarters was officially upgraded to China and East Asia Headquarters
Siemens announced that from October 1, 2022, its Siemens Electric Products China headquarters in Gusu will be officially upgraded to China and East Asia headquarters, and its responsibilities will be extended to cover the business in East Asia, including Korea and Japan. The upgrade has been fully supported by the Gusu Municipal People's Government ...
|
|
What does the fan of the Siemens 3RW soft starter do?
The function of the 3RW soft starter fan is to speed up the heat dissipation, which can effectively improve the operating frequency of the soft starter. 3RW30 soft starter cannot be equipped with a fan.
3RW402-404 Soft Starter Fan is not a standard equipment ...
|
|
Basic data types supported by Siemens S7-1200
The basic data types supported by the Siemens S7-1200 include the following:
Boolean data is a one-digit binary number, the value of which is 0 or 1, and the constant value of the data is TRUE, FALSE, 0, 1, etc. The byte-type data is an eight-digit binary number, and the value scale is 16-base 00 to 16-base FF, ...
|
|
The Siemens soft starter 3RW44 can self-reset and can fail
Not all faults can achieve self-reset, and the faults that can achieve self-reset are as follows, (the method of self-reset is to set the corresponding parameters in the menu of the LCD display):
1) The motor thermal model is overloaded. The way to achieve self-reset is to select "Settings" -> "Response..." -> "Thermal ...
|
|
Siemens released its third-quarter financial results
Siemens, as a dedicated technology company, delivered significant results in the third quarter of fiscal 2022 (ended June 30, 2022). The macroeconomic environment remains chaotic due to factors such as economic sanctions against Russia, high inflation and the coronavirus pandemic, but Siemens is still in many key malls.
|
|
Common solutions for Siemens G120 inverter F08502 faults
1 Check whether there is EMC interference in the inverter or network cable
To ensure that the inverter is firmly grounded, the grounding resistance of the inverter is generally required to be less than 4 ohms.
Industrial-grade shielded network cables and network cable connectors are used
The shielding layer of the network cable should be firmly grounded, and the shielding of the more ambitious ...
|
|
The Siemens CNC Digital Empowerment Center was officially launched in Nanjing
The Siemens CNC Digital Empowerment Center (hereinafter referred to as MTS DEAX) was officially launched in Nanjing today. From the original skill use center to the experience and empowerment center, MTS DEAX not only comprehensively demonstrates Siemens' cutting-edge machine tool CNC system processing plan covering the whole value chain, but also ...
|
|
Siemens joins hands with Chery to stimulate new momentum for the development of the automotive industry
Chery is a leading manufacturer of self-owned brand cars in China and one of the largest passenger car exporters in China. In recent years, Chery has actively practiced the core strategy of "Digital Chery", and built an intelligent and connected "factory of the future" in Wuhu, Anhui Province, accelerating the transformation from "traditional cars" to "smart cars".
|
|
Siemens S7-200 SMART Common questions about serial communication
1.Does the S7-200 SMART support Modbus ASCII communication mode?
The STEP 7-Micro/WIN SMART software does not provide a library of Modbus ASCII communication modes. If the S7-200 SMART CPU is used for Modbus ASCII communication, it needs to be used by the user to use the free port communication.
|
|
Siemens CEO Philip Boleren delivered a speech at the opening ceremony of the World Artificial Intelligence Conference
The 2021 International Artificial Intelligence Conference (WAIC) was officially opened, and Roland Busch, Chairman of the Board of Directors, President and CEO of Siemens AG, was invited to attend the opening ceremony and deliver a speech.
Bo Leren pointed out that digital transformation is the key to all shopping malls and even social and economic ...
|
|
Siemens PLC has six common fault-prone points
1. The first type of fault point is also the location of the most faults in relays and contactors
For example, in the daily maintenance of the PLC control system of a production line, the largest consumption of electrical spare parts is all kinds of relays or air switches. In addition to the quality of the product itself, it is mainly due to the fact that the on-site environment is more ...
|
|
Siemens supports the transition to sustainable infrastructure with new digital solutions
Siemens unveiled its face at the 2022 Lighting and Construction Electrical Exhibition in Frankfurt, Germany under the theme of "Smart Infrastructure Can Continue Infrastructure". During the exhibition, Siemens Essentials underlined its digital vision as the infrastructure needed to address climate change and global sustainability challenges.
|
|
Siemens' intelligent manufacturing engineering talent certification system was officially released
Siemens recently officially launched the Intelligent Manufacturing Engineering Talent Certification System, and the first batch of 12 campuses were certified. Siemens combines its advanced intelligent manufacturing skills with practical experience in the field of engineering education to organize the central digital talents required for modern industrial systems.
|
|
Siemens acquires Brightly Software to accelerate its development in the field of smart buildings
Siemens Intelligent Infrastructure recently announced that it has signed an agreement to acquire Brightly Software, a SaaS provider of asset and protection management solutions in United States. The acquisition will strengthen Siemens Intelligent Infrastructure's position in the building and infrastructure software segment. Harvest...
|
|
Siemens publishes a white paper on leadership
Siemens today released the Siemens Leadership China White Paper (hereinafter referred to as the "White Paper"), which combines the evolution of leadership theory and its performance in the business environment, comprehensively sorts out the development and upgrading of its own leadership methodology and its application in the course of more than 100 years, and deeply analyzes the development and upgrading of its leadership methodology and its application over the past century.
|
|
Siemens 3RW44 soft start press emergency start why not
The 3RW44 has an emergency start function, but why does the soft start not start when the emergency start button is closed?
Emergency start refers to the unevenness of the motor; thermal model overload; Open circuit of temperature sensor; Short circuit of the temperature sensor; The temperature sensor is overloaded; Exceeding the maximum starting time; Surpass...
|