Hollysys won the 2022 China Intelligent Transportation Association Science and Technology Award"

Create Date: 2024-8-30 12:03:23|Source: HollySys/HollySys

On October 18, 2022, the China Intelligent Transportation Association released the list of winners of the "2022 China Intelligent Transportation Association Science and Technology Award", which includes the Science and Technology Progress Award, the Technology Invention Award, and the Outstanding Innovative Talent Award. Among them, Beijing Hollysys System Engineering Co., Ltd., as the first completion unit, jointly with China Railway Xi'an Bureau Group Co., Ltd. and Xi'an Hollysys System Engineering Co., Ltd., jointly declared the "Research and Application of Key Technologies for Intelligent Maintenance of Railway Signaling Equipment Based on Full Life Cycle Management" project won the "Third Prize of Science and Technology Progress Award of China Intelligent Transportation Association in 2022".
Hollysys won the 2022 China Intelligent Transportation Association Science and Technology Award"
Hollysys won the 2022 China Intelligent Transportation Association Science and Technology Award"
  The Science and Technology Award of China Intelligent Transportation Association implements the policy of respecting labor, respecting knowledge, respecting talents, and respecting creation, encourages unity and cooperation, joint research, encourages independent innovation, promotes scientific research, technological development and economic and social development, accelerates the commercialization and industrialization of scientific and technological achievements, and accelerates the development of China's intelligent transportation industry. It aims to award organizations and individuals who have made outstanding contributions to China's intelligent transportation science and technology innovation, technological invention, achievement promotion and application, high-tech industrialization, and major engineering construction.

Based on the core requirements of the whole life cycle management, Hollysys put forward the topic of "Research and Application of Key Technologies for Railway Signal Equipment Maintenance Based on Full Life Cycle Management", completed the integration of testing equipment, management system software development and auxiliary equipment required for the maintenance base, carried out process planning for the operation requirements and operation objectives of the maintenance base project, and realized the improvement and application of the intelligent maintenance base of railway signal equipment in informatization, intelligence and automation. The overall results of the project have reached the domestic advanced level, among which the switch machine cleaning and surface spraying equipment have reached the domestic leading level in terms of maintenance automation application.

In the future, Hollysys will continue to give full play to its corporate advantages, improve its product ecology, enhance its product technology innovation capabilities, and play a more important role in the development of the railway transportation industry.

More on that
Troubleshooting steps of Hollysys DCS system Troubleshooting steps of Hollysys DCS system

The steps of DCS system troubleshooting include: (1) Check the fault caused by improper use. Common types of operational faults include operator errors, terminal wiring faults, module installation faults, and power supply failures. (2) Troubleshoot the improper operation of the DCS system ...

Hollysys PLC – PLC programming advice Hollysys PLC – PLC programming advice

(1) When the PLC and the host computer (or touch screen) form a monitoring system, there are many times when there are "manual", "automatic" and other control modes on the screen (generally when there is only one multiple). You can use the "MOV" command in the program. For example, when "manual" is selected, the constant 1 MO ...

Hollysys plc - the difference between DCS and PLC Hollysys plc - the difference between DCS and PLC

1. DCS is a "distributed control system", while PLC (programmable controller) is just a control "device", which is the difference between the two. The system can realize the function and coordination of any equipment, and the PLC equipment only realizes the function of this unit. 2. In terms of networking, the DCS network is ...

Hollysys PLC – How to calculate the analog quantity in PLC Hollysys PLC – How to calculate the analog quantity in PLC

1、-10—10V。 When the voltage of -10V-10V is converted to F448-0BB8Hex (-3000-3000) at 6000 resolution; At 12000 resolution, it is converted to E890—1770Hex (-6000—6000). 2、0—10V。 At a voltage of 0-10V, at a resolution of 12000 ...

Hollysys DCS - Introduction to the advantages and disadvantages of DCS Hollysys DCS - Introduction to the advantages and disadvantages of DCS

Merit: 1. High reliability: The DCS system has multiple redundancy, backup and recovery mechanisms, which can ensure the high reliability and stability of the system. 2. Sensitivity: The DCS system can be customized according to different industrial processes to meet different control requirements. 3. Efficiency: D...

Hollysys PLC - How to maintain the PLC control cabinet? Hollysys PLC - How to maintain the PLC control cabinet?

1. Data backup When carrying out maintenance, we must cut off the power, data backup between power outages is an important link, for the data that needs to be archived for a long time, you can back up the historical trend data to the mobile hard disk, and then turn off the Windows-based operating system (Note...

HollySys PLC – 8 common error types of PLC HollySys PLC – 8 common error types of PLC

Various brands of PLCs have a self-diagnosis function, but the trick of PLC repair is to make full use of this function to analyze and then pinpoint the problem. Sorted out the 8 common types of errors that PLC repairmen need to know when the PLC presents abnormal alarms. 1. CPU abnormality ...

Hollysys successfully signed a contract with Luxi Chemical for a 1.2 million tons/year bisphenol A plant project Hollysys successfully signed a contract with Luxi Chemical for a 1.2 million tons/year bisphenol A plant project

Recently, Hollysys successfully signed a contract with Luxi Chemical Group Co., Ltd. (hereinafter referred to as Luxi Chemical) for a 1.2 million tons/year bisphenol A equipment project. The project is a key project in Shandong Province in 2021, which will not only greatly improve the competitiveness of Luxi Chemical polycarbonate in the industry, but also have a significant impact on China's phenol ...

Hollysys PLC - What are the three large quantities in PLC? Hollysys PLC - What are the three large quantities in PLC?

1. The switching quantity is also called the logical quantity, which means that there are only two values, 0 or 1, ON or OFF. It is the most commonly used control, and controlling it is the advantage of PLC, and it is also the most basic application of PLC. The purpose of switching control is to follow the current input combination with the historical input according to the switching quantity.

Hollysys delivered a keynote speech at CAIMRS 2023 and won a number of awards Hollysys delivered a keynote speech at CAIMRS 2023 and won a number of awards

The "2023 China Automation + Digital Industry Annual Conference", "The 19th CAIMRS and Digital Leaders Forum" and the "Annual Award Ceremony" were successfully held in Suzhou. The theme of this summit is "Powerful Digital Intelligence, Junfa New Industry", combined with post-epidemic recovery, digital intelligence, and new industrialization.

Hollysys DCS - DCS common communication faults and solutions Hollysys DCS - DCS common communication faults and solutions

01 Node bus failure The node bus material is usually a coaxial cable, so as long as there is a cable disconnected, the communication of all devices on the bus will be paralyzed, which will cause serious phenomena such as data loss, equipment stoppage and operation interruption, and may eventually directly or indirectly cause huge ...

Steps on how Hollysys DCS works on a computer Steps on how Hollysys DCS works on a computer

1. Confirm that the new computer has relevant interfaces and can be used normally, and Hollysys DCS software can run on the computer operating system 2. Device and Lisi DCS software, dongle, and related drivers (mainly redundant network cards, data hard disks, etc.) 3. Set up ...

Hollysys PLC - Precautions in the operation of PLC (1) Hollysys PLC - Precautions in the operation of PLC (1)

First, the working environment (1) Temperature The PLC requires that the ambient temperature is 0-55oC, and it cannot be placed under the components with large heat generation during installation, and the surrounding ventilation and heat dissipation space should be large enough. (2) Humidity In order to ensure the insulation performance of PLC, the relative humidity of the air ...

Hollysys DCS - the selection, design and debugging of DCS system Hollysys DCS - the selection, design and debugging of DCS system

1. The configuration of the system and controller should focus on reliability and load rate (including redundancy). The communication load rate must be controlled within a reasonable range, and the load rate of the controller must be balanced as much as possible to avoid the occurrence of "high load" problems. 2. The distribution of system control logic should not be too much.

Analysis of common problems of Hollysys DCS system Analysis of common problems of Hollysys DCS system

1. What is a communication protocol? A communication protocol is an agreement between two parties to a communication. The agreement includes uniform provisions on data format, synchronization mode, transmission speed, transmission steps, error detection and correction mode, and control character definition, etc., which must be complied with by both parties to the communication. Therefore...

Hollysys DCS - What are the four contents of DCS spare parts management? Hollysys DCS - What are the four contents of DCS spare parts management?

DCS spare parts In the process of using the DCS control system, its management is more important. The requirements of general DCS spare parts management are summarized in four aspects: storage, inspection, preparation for use, and use. 1. Storage DCS system, spare module storage should meet the requirements ...

Hollysys PLC - nine precautions for the use of PLC Hollysys PLC - nine precautions for the use of PLC

1. PLCZ self-fault judgment In general, PLCs are extremely reliable devices with a very low failure rate. The probability of hardware damage such as the CPU of the PLC or software running errors is almost zero; If the PLC input point is not caused by strong current intrusion, it will hardly be damaged; PLC output relay ...

Hollysys DCS - the main factor of DCS signal interference Hollysys DCS - the main factor of DCS signal interference

Resistive coupling interference In the process of work, many factories ignore the problem of wire aging. When a variety of signal lines are transmitted together, other transmission signals will be affected due to the aging and leakage of the insulation material on the wire, and other transmission signals will be interfered with. ...

Hollysys DCS output module - K-AO02 advantages introduced Hollysys DCS output module - K-AO02 advantages introduced

1. The output accuracy is as high as 0.05%, which greatly improves the operation efficiency of the system. 2. The full-scale output of the channel signal is 0-22.7mA, and the output range is wide; 3. It can be adapted to the enhanced base to achieve channel resistance to 220VAC; 4. It has a perfect channel signal diagnosis function, which can be realized.

Hollysys signed a contract with Lysys for the integrated management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan Hollysys signed a contract with Lysys for the integrated management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan

Recently, Hollysys signed a contract for the comprehensive management platform project of smart tunnel of Linzhou-Changzhi Expressway in Henan Province. Linzhou to Changzhi Expressway is a traffic artery that crosses the Grand Canyon of Taihang Mountain, through Henan and Shanxi, with a total of 7 pairs (14) tunnels.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top