The structure of Delixi small contactor

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi's communication contactor is widely used in industrial electrical, contactor as a kind of electromagnetic switch, its interior is mainly composed of the main and auxiliary contacts and electromagnetic coils, static cores and other parts of the control line connection and breaking.

  ​                      The structure of Delixi small contactor

The operating principle of Delixi small contactor is to let the contactor coil get the flow of current, the coil will generate many magnetic fields around it, the magnetic field effect it produces, can make the contact open and the contact closed, generally disassemble the plastic shell of the contactor can see its internal basic structural composition. The diagram shows the internal structure of a typical communication contactor. Therefore, the operating principle of the contactor is not very messy with the principle of the electrical switch we usually use.

A short-circuit ring is installed on the static iron core of the communication contactor, which is mainly used to reduce the oscillation and noise generated when the communication contactor is engaged; The solenoid coil is wound by insulated wires, and two magnet wires are led out at both ends and connected to the external line through the terminal block; There are generally multiple groups of contacts of communication contactors, during which they are mostly composed of a group of main contacts (3 normally open contacts) and multiple groups of auxiliary contacts (normally open auxiliary contacts and normally closed auxiliary contacts, the number of contacts is not necessarily) in practical applications.

Delixi small contactor on the operation of the motor will be more and more convenient, bento, it itself with the full active control effect, can actively control the current, all kinds of welding machine, capacitor machine, electric heater and so on will be embedded in this Delixi small contactor.

Delixi small contactor in our life is very widely used, and household appliances have an inseparable connection, Delixi small contactor relay can protect the safety of large current, so in the event of a risk situation will take the initiative to trip, disconnect the current.

More on that
Delixi time control switch adjustment method Delixi time control switch adjustment method

Press the undo function key first, then press and hold the school time function key, then adjust the time and date to the current moment, press the punctual function key again, adjust the time that needs to be closed and open to the specified value, if you need to set multiple groups, then press the punctual function key to set, without multiple groups ...

Delixi CDRA soft starter features Delixi CDRA soft starter features

Delixi CDRA soft engine is a set of soft start, soft stop, light load, energy saving and multi-functional protection in one of the motor control equipment. This is a shock-free and smooth motor during the entire start-up process. According to the type, it can be divided into equipment type and comprehensive. ...

Delixi inverter in the single girder crane electric hoist application case Delixi inverter in the single girder crane electric hoist application case

Single-beam crane throughout the use of electric hoist as a lifting mechanism, with a simple structure, convenient use, widely used in some lifting tonnage small industrial and mining enterprises, domestic hoist crane throughout the use of conical rotor motor, cone motor structure than the general motor messy, ordinary method speed regulation is more difficult ...

Delixi inverter all aspects of the selection of precautions Delixi inverter all aspects of the selection of precautions

The inverter is a device that can control the speed of the motor, and it completes the speed regulation by adjusting the voltage and frequency of the motor. When selecting an inverter, there are several factors to consider, including the power of the motor, the type of load, the operating environment, etc. This article will specifically introduce the selection of frequency converters ...

Advantages of Delixi parameter voltage regulator Advantages of Delixi parameter voltage regulator

1. Its overall induction skills are the best, its design does not use electronic devices, and the environmental adaptability and stability are the highest. When the capacity of most power grids is sufficient, the voltage is relatively stable, but with the improvement of electrification and informatization, the pollution of some power grids, ...

Delixi voltage regulator boot voltmeter does not indicate fault analysis and solutions Delixi voltage regulator boot voltmeter does not indicate fault analysis and solutions

When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem phenomenon and cause analysis 1. The plug is not plugged in firmly, and there is no output voltage 2. The fuse is broken When the Delixi voltage regulator is turned on, the voltmeter does not indicate the problem is solved ...

Resistance quantization circuit exerts resistance to the flow of current – Delixi Resistance quantization circuit exerts resistance to the flow of current – Delixi

We are able to compare the values of resistance and hose diameter (conductance vs. practical diameter). When it comes to metal wires, this analogy works well. Small-diameter wires have a higher resistance than large-diameter wires made of the same metal. The standard unit of resistance is ohms, there are ...

Product features of Delixi equalizer Product features of Delixi equalizer

1. The divider is the sixth generation of intelligent machine using microcomputer chips, and the intelligent program is very high. 2. Single-phase three-phase connection, the divider on the market is scored as A, B, and C three-phase wiring for three-phase electricity, which is not only inconvenient for installation, but also prone to phase sequence errors. 3. Can ...

The reason why the switch socket is hot - Delixi The reason why the switch socket is hot - Delixi

1. The socket quality is low quality First of all, we should check whether the socket is a miscellaneous and inferior product, the copper clamping force in the defective socket is not good, resulting in poor contact between the socket and the plug, and the socket and plug will heat up after a long time of electrical use. So be sure not to buy cheap miscellaneous ...

Circuit breaker control loop to reduce damage method - Delixi Circuit breaker control loop to reduce damage method - Delixi

1 Anatomy of the causes The various causes of the burning of the control loop components of the unmanned station are analyzed and classified as follows: · When the personnel on duty operate, the precautions are not well grasped or the operation is improper; · The organization does not lock and close the operation when it is not stored in energy, and the auxiliary contact of the switch cabinet ...

Delixi E180 universal inverter introduction Delixi E180 universal inverter introduction

Product Introduction With optimized open-loop vector control, V/F control, closed-loop vector control, stable function, function optimization, it is a high-function vector inverter, which can be widely used in speed control accuracy, torque echoing speed...

Delixi three-phase motor electrical control circuit principle Delixi three-phase motor electrical control circuit principle

What is the principle of the electrical control circuit of the three-phase motor? First of all, let's take a look at what is the principle of electrical control of work machinery. The schematic diagram of the electrical control circuit of the working machinery is actually connected with graphic symbols, text symbols and lines to show the connection relationship and circuit of each electrical component.

The operating structure of the high-voltage circuit breaker - Delixi The operating structure of the high-voltage circuit breaker - Delixi

1. Classification of switch operation organization At present, the switches we encounter are generally divided into many types, such as oil-rich type (old model, now you can't see it at all), oil-poor type (some user stations also have it), SF6, vacuum, GIS (combined electrical appliances) and so on. These are all about the arc extinguishing medium of the switch. ...

Delixi solid state relay over AC contactor advantages Delixi solid state relay over AC contactor advantages

Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose? 1. First of all, solid...

Delixi DZ47S wiring method Delixi DZ47S wiring method

The general leakage circuit breaker is used to wire the principle of the upper and lower lines, as long as the phase line and the zero line can be distinguished, between, the zero line is marked with N on the right, and the incoming and outgoing lines are the same. Delixi DZ47LE C40 ...

Introduction to the closed-loop control system of stepper motor Introduction to the closed-loop control system of stepper motor

1. The closed-loop control of the stepper motor was first in the form of encoder For stepper motors with low split ratio, a slotted disc and photoelectric sensor are usually used as a reaction encoder assembly, and the number of notches is equal to the number of steps taken by the motor per revolution, · About high resolution ...

Inverter application skills - Delixi Inverter application skills - Delixi

1. Shielded wires should be used for signal lines and control lines, which is beneficial to avoid disturbance. When the line is long, for example the distance jumps 100m, the conductor cross-section should be enlarged. The signal line and the control line should not be placed in the same cable trench or tray with the power line, so as not to disturb each other, it is best to place it through the pipe, ...

Delixi circuit breaker P number selection points Delixi circuit breaker P number selection points

As far as miniature circuit breakers are concerned, 1P+N, 1P, and 2P are generally used as the on-off control of single-phase electrical appliances, but the functions are different. In order to facilitate the user's selection and difference, the difference of the P number of circuit breakers and the selection method are briefly analyzed. ...

The difference between Delixi single-phase and three-phase AC voltage regulators The difference between Delixi single-phase and three-phase AC voltage regulators

Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on. ...

Delixi voltage regulator problem repair Delixi voltage regulator problem repair

1. The output voltmeter is constantly swinging back and forth, and sparks are generated at the carbon brush 1. The contact pressure between the carbon brush and the coil plane is too small 2. The carbon brush is severely worn 1. Clean the coil and carbon brush with a fine file or sandpaper, and then adjust the carbon brush pressure 2. Replace the carbon brushes with new ones ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top