Siemens is further expanding the capabilities of the Sinumerik ONE "digital native" CNC system. For this new generation of CNC system launched in 2019, Siemens has made innovations in both software and hardware this year. With Sinumerik V6.20 software, Sinumerik ONE has new technical capabilities that simplify operation, reduce machine wear and tear, and increase productivity. With this update, Siemens is once again demonstrating how the powerful Sinumerik ONE machine CNC can be used to achieve digital transformation in an efficient, agile and modular way.
With the new Y-turning function, the Sinumerik ONE can now be used on machines with Y-axis turning and increases productivity by a factor of 3 with a three-fold increase in feeds. In addition, new tools have been developed to adjust all turning functions and cycles accordingly.
The Advanced Rapid Movement function optimizes the delivery time. Applying this function in cooperation with the machine builder allows the customer to achieve faster transmission between machining operations without changing the part program, increasing the machining speed by about 10 percent.
The new NCK function for Reduced Dynamic Mode reduces wear and improves machine availability. For example, when a shaft overheats, the machine builder can use the NCK function to proactively adjust the machine to a simple operation and proactively recover to full load when the overheating problem is resolved. With the support of the new function, the machine tool can complete the active opening and closing operation in a dynamic form during operation.
On the hardware side, Sinumerik ONE simplifies operation even further: a new keypad and machine control panel (MCP) from 15 to 24 inches are available to match the HMI. At the same time, Simatic Industrial Thin Clients (ITCs) and Industrial PCs will soon be available with higher functionality and resolutions of up to 1920 x 1080 pixels.
The new machine control panel is also integrated into the digital twin of Sinumerik ONE (Create and Run MyVirtual Machine), where the panels look and operate in the virtual world to correspond to the CNC system in the real world. In addition, the digital twin of Sinumerik ONE introduces a number of new features that simplify engineering and preparation for production, such as: pass/3D option to complete the support of the second channel; The support assigns different colors to different tools so that the cutaways can be color-coded according to the tool used; Import the STEP format to better handle cluttered shapes in turning operations.
The function of bump detection has also been further expanded, and it can complete the display of all bump objects and NC program lines in order to quickly investigate and eliminate the cause of bumps.
|
More on that
|
How to remove the IP address with a SIMATIC MC memory card and reset the S7-1200 to factory settings
You can reset your S7-1200 to factory settings using an empty SIMATIC MC memory card.
illustrate
Even if you don't have SIMATIC STEP 7 Basic software and don't know the IP address, you can use the SIMATIC MC memory card to delete the IP address and put the S7-1 ...
|
|
Siemens and Guangdong Shicheng work together to build a native digital factory
The industrial sector is in the midst of a digital revolution, and Siemens is committed to helping our customers transform into truly digital enterprises and make them more competitive on the road to the industrial future.
Founded in 2003, Guangdong Shicheng Plastic Machinery Co., Ltd. is a collection of scientific research and development.
|
|
3RW44 How to start and stop the motor by the button next to the LCD screen
Step 1: In the third item "Standard Control" in the motor control, select "Button"
Step 2: Then in "Control Motor by Button", "Key Control" is selected to activate
Step 3: Then in "Control Motor by Button", "Parameter Group", select the parameter ...
|
|
Siemens 3RW51 soft starter working principle and selection precautions
3RW51 soft starter is a new domestic soft starter product developed and launched by Siemens on the basis of a deep understanding of the soft start application in the market. It can be widely used in fans, pumps, conveyor belts, compressors and other loads that need to be controlled for starting and stopping.
Soft starter ...
|
|
Does the power supply cable between the Siemens soft starter and the motor need to be shielded?
For 3RW soft starters, it is sufficient to use an unshielded main loop cable between the motor and the 3RW soft starter.
The main reasons are as follows:
The frequency of the power supply on the motor terminals is stabilized at 50 or 60 Hz throughout the operation of the soft starter
After the soft start is completed, the main ...
|
|
SIMATIC S7-1200 compact CPU
Installation
1. Remove the backplane bus cover
2. Insert the SM onto the standard mounting rail
3. Push the SM to the adjacent module
4. Lock the standard rail mounting clip
5. Push the latch used to connect the bus connector to the left so that the bus pin is connected to the adjacent module
...
|
|
Siemens will participate in the 5th CIIE
Siemens will be exhibiting at the 5th China International Import Expo (CIIE) with the theme of "Science and Technology, Create Every Day". On the occasion of the 150th anniversary of joining hands with China, Siemens will fully demonstrate the key milestones of its development in China, and will share its ...
|
|
Siemens joins hands with Hisense to explore the home appliance industry
Siemens recently signed a strategic cooperation agreement with Hisense Group Holding Co., Ltd. (Hisense). The two sides will be based on Siemens' preemptive digital business portfolio, as well as the successful practice of digital transformation, to promote Hisense's digital construction together, and explore the development of intelligent production in the home appliance industry.
|
|
HBIS and Siemens have established a comprehensive strategic partnership
The iron and steel industry is the backbone of national modernization and an important industry to support the development of the national economy. Without steel, there would be no high-rise buildings, railways and highways in all directions. The importance of this cannot be overstated.
In recent years, the steel industry has seen overcapacity and ...
|
|
Siemens builds a super digital factory for small pots of tea
In June 2022, with the help of Siemens, the super factory built by Xiaocan Tea with an investment of 1.5 billion yuan in Huangshan, Anhui Province was officially put into operation, providing a modern demonstration model for Chinese tea enterprises and leading the arrival of the "Tea Industry 4.0" era.
As the first tea profession in China to start with "...
|
|
Siemens joins hands with COFCO Great Wall to create a benchmark for intelligent manufacturing in the food and beverage industry
Siemens and COFCO Great Wall Wine Co., Ltd. (COFCO Great Wall) today signed a strategic collaboration agreement at the "Siemens Food & Beverage Career Ecology Summit", which will establish a strategic collaboration relationship in the field of food and beverage professional intelligent production and Internet of Things, and jointly build a strategic cooperation agreement suitable for COFCO Great Wall and even China.
|
|
How do I clear the error status 16 # 8382 when I am connected to a Modbus TCP between SIMATIC S7-1500/S7-1200 and a SENTRON PAC device?
The S7-1500 CPU or S7-1200 CPU uses the "MB_CLIENT" command as a Modbus TCP client via the integrated PROFINET interface. Use the "MB_CLIENT" command to establish a connection between the Modbus TCP client and the Modbus TCP server. Fig. 1 as ...
|
|
Siemens acquires Brightly to improve its building operation capabilities
Siemens Smart Infrastructure (SI), a leader in digital construction, has acquired Brightly Software, a leading software-as-a-service (SaaS) provider of property and maintenance management solutions in the United States. The acquisition elevates the SI to ...
|
|
The Siemens soft starter 3RW44 can self-reset and can fail
Not all faults can achieve self-reset, and the faults that can achieve self-reset are as follows, (the method of self-reset is to set the corresponding parameters in the menu of the LCD display):
1) The motor thermal model is overloaded. The way to achieve self-reset is to select "Settings" -> "Response..." -> "Thermal ...
|
|
How to use a Siemens memory card to wipe the password or do a factory reset
If the customer forgets the password that was previously set to the S7-1200, the program and password inside the S7-1200 cannot be erased by "Factory Reset", so the only way to clear it is to use the memory card. The detailed steps are as follows:
1. Use a memory card, insert it in a computer card reader, ...
|
|
Common problems with the S7-200 SMART high-speed counter
Why does assigning initial and preset values to a high-speed counter not work, or the effect is unexpected?
The high-speed counter can be initialized or changed during operation, such as initial values and preset values. The procedure should be:
Set update options for control bytes. Need...
|
|
Siemens helps Chinese paper bag machine companies compete in the international market
Founded in 1997, Nanjing Zhuo Neng Machinery Equipment Co., Ltd. (Zhuo Neng) is an "expert" in the field of paper bag machines, and with the empowerment of technology with Siemens, this company has achieved a compound annual growth rate of more than 30% in sales in the past three years.
Headquartered in the ancient capital of Jinling, Zhuo Neng is a ...
|
|
Siemens introduces a new generation of industrial Ethernet switches
At SPS 2022 in Nuremberg, Siemens introduced the new generation of Scalance XC-/XR-300 series Industrial Ethernet switches. With the increasing number of machines, controls and IT systems connected to the network in industrial production, the network at the production level is also ...
|
|
Siemens S7-200 SMART Common questions about serial communication
1.Does the S7-200 SMART support Modbus ASCII communication mode?
The STEP 7-Micro/WIN SMART software does not provide a library of Modbus ASCII communication modes. If the S7-200 SMART CPU is used for Modbus ASCII communication, it needs to be used by the user to use the free port communication.
|
|
How to understand the trip level of Siemens 3RW soft starter (Class level)
The trip class (Class class) defines the time frame during which a tripping must be carried out from the cold state when the current of a three-symmetrical load (e.g. a three-phase motor load) is 7.2 times the operating current Ie. Trip time:
Siemens 3RW soft starter is divided into light and heavy load starting motors according to trip level ...
|
|