Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

How many types of protection devices are there for transformers?

A: Overcurrent protection, current quick break protection, differential protection and gas protection.

  What are the requirements for relay protection?

Answer: In order to be able to remove faults correctly and quickly, relay protection is required to have sufficient selectivity, rapidity, sensitivity and reliability.
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

More on that
Rittal cables support factory assembly and cabling Rittal cables support factory assembly and cabling

Imagine you walk into a large, well-maintained room with many cabinets and mounting plates waiting to be machined. Several staff members focus on assembly and wiring work. Another thing that will surprise you is the complete absence of paper – no folders crammed with circuit diagrams, and no work orders. This ...

Common faults and solutions for Rittal cabinet air conditioners Common faults and solutions for Rittal cabinet air conditioners

If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start; Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high. The voltage of the air conditioner is unstable, and the compressor cannot be started normally.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What to do if you notice someone electrocuted? Answer: First of all, make the electrocuted person quickly disconnect from the power supply. Its method, for low-voltage electric shock, can be used "pull", "cut", "pick", "pull", "pad" method, pull or cut off the power supply, the operation should pay attention to avoid people rescue people electric shock, should ...

Rittal cabinets – the cause of moisture in electrical cabinets Rittal cabinets – the cause of moisture in electrical cabinets

(1) The cause of moisture in the cabinet 1) Environment shutdown. The ring main unit or the opening and closing station itself is a closed environment, because of the poor ventilation conditions, it is easy to gather moisture and generate condensation, and there are many large buildings today in order to reduce the occupied area, the opening and closing station, the power distribution room is built in the basement. Cause...

A detailed assortment of Rittal products A detailed assortment of Rittal products

Rittal's products are: Rittal control cabinets: small cabinets (polycarbonate cabinets PK, junction boxes KL, compact control boxes EB, bus cabinets BG), compact control cabinets, plastic control cabinets KS, cabinet systems (subdivided into TS 8/SE 8 family), parallel cabinet systems...

Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets Rittal cabinets – the uses and characteristics of commonly used low-voltage distribution cabinets

▲ GGD AC low-voltage distribution cabinet: (1) Use GGD type AC low-voltage distribution cabinet is suitable for substations, power plants, factories and mining enterprises and other power users AC 50Hz, rated working voltage 380V, rated working current 1000-3150A distribution system, as a power ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the main technical parameters of the fuse? Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage. What are the main products of low-voltage power distribution equipment? Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...

Rittal presents a number of green and innovative sanitary cabinets at CBST Rittal presents a number of green and innovative sanitary cabinets at CBST

On April 7, 2023, the 11th CBST China International Beverage Industry Technology Exhibition was grandly held at the Shanghai New International Expo Center.   As a practitioner of the concept of "intelligent manufacturing" in Germany, Rittal brings many green and innovative sanitary cabinet systems and temperature control solutions.

Rittal cabinet fittings Rittal stainless steel rain cover for AE model 2472.000 Rittal cabinet fittings Rittal stainless steel rain cover for AE model 2472.000

Stainless steel rain top cover for AE Product model 2472.000 Outdoor fixtures are safely and reliably protected with a drain channel at the back. Material: Stainless steel 1.4301 (AISI 304). Product Description: Safe and reliable protection for outdoor installations, with ...

Rittal cabinets – what are the characteristics of explosion-proof cabinets compared to ordinary cabinets? Rittal cabinets – what are the characteristics of explosion-proof cabinets compared to ordinary cabinets?

1. It can be installed in places where dangerous gases exist, and it is safe to use the control cabinet in some environments with gas or vapor gas. 2. The shell of the control cabinet is generally made of steel plate welding or cast aluminum alloy die-casting, with high-voltage electrostatic spraying, and the whole is made of flameproof type.

Rittal cabinet air conditioner fault code Rittal cabinet air conditioner fault code

The fault codes for Rittal cabinet air conditioners are: F1, F2, F3, FF, EH, EP, EL, SF, HC. F1, F2, F3 represent improper use or failure of internal components; FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault; EP stands for Actuator Failure; ...

Rittal cables – the basic structure of power cables Rittal cables – the basic structure of power cables

1. Core: The core is the conductive part of the power cable, which is used to transmit electric energy and is the main part of the power cable. 2. Insulation layer: The insulation layer is to electrically isolate the core from the ground and the cores of different phases to ensure the transmission of electric energy.

What are the main problems in the practical application of Rittal cabinet air conditioners on the client? What are the main problems in the practical application of Rittal cabinet air conditioners on the client?

Through continuous big data analysis of 200,000 cabinet air conditioners installed and operated on the market, Rittal found that the main problems in the actual application of air conditioners on the client are as follows: 1. Lack of maintenance, resulting in clogged air conditioner filters, which in turn causes the air conditioner to stop running or ...

Rittal cabinets – maintenance rules for network cabinets Rittal cabinets – maintenance rules for network cabinets

1. Once a month (8 hours at the end of the month), and make a maintenance record. 2. Clean the gears of the whole machine to ensure the cleanliness and normal clearance of the gears. 3. Check the gap between the two gears at the punching device of the processing department and adjust the clearance. 4. Adjust the gap between each ink roller to ensure that ...

Rittal cabinets – maintenance methods for motor control cabinets Rittal cabinets – maintenance methods for motor control cabinets

1. Disconnect the power supply, check whether the rack of the control cabinet has reliable grounding, and make the grounding resistance not greater than 4Ω. 2. There are voltages of different properties on the control cabinet (DC 110V; Communication single-phase 220V; Three-phase communication), the circuit must be distinguished during maintenance to avoid short-circuit accidents.

Common fault codes and handling methods for Rittal cabinet air conditioners Common fault codes and handling methods for Rittal cabinet air conditioners

1. E0: Indoor temperature sensor is faulty. When this fault code appears, you need to check whether the indoor temperature sensor is working properly. 2. E1: Outdoor temperature sensor failure. When this fault code appears, you need to check whether the outdoor temperature sensor is working properly. 3. E2 ...

Rittal at the Hannover Messe 2022 in Germany Rittal at the Hannover Messe 2022 in Germany

"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...

Common faults and troubleshooting methods of oil coolers - Rittal cabinets Common faults and troubleshooting methods of oil coolers - Rittal cabinets

Fault symptom 1: insufficient cooling capacity Cause analysis (1) The room or box is not sealed or the thermal insulation performance is poor (2) The evaporator frost is too thick (3) The efficiency of the compressor deteriorates (4) The expansion valve is too large or too small (5) There are more ...

Rittal enclosures – types of sheet metal enclosures Rittal enclosures – types of sheet metal enclosures

In terms of structure, there are two ways to classify sheet metal cabinets: According to the division of the cabinet frame, it can be divided into the whole plate type and the column and beam combination type; According to the way of cabinet angle connection, it can be divided into four forms: adhesive connection, screw connection, pin connection and welded connection. ...

Air conditioner shows H1 fault code solution – Rittal Air conditioner shows H1 fault code solution – Rittal

1. The air conditioner displays the H1 fault code - the reason When the outdoor temperature is low and the humidity is high, the heat exchanger of the outdoor unit will be frosted after the air conditioner runs for a period of time, then the automatic defrost function will be activated, and the heating operation will be temporarily stopped for 5-10 minutes. Air conditioner heating defrost shows H1 which is normal ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top