Some advantages of the Rittal compact AE enclosure

Create Date: 2024-8-30 12:03:23|Source: Rittal/Rittal

The Rittal compact AE cabinet with its new internal expansion rails

–Supplementary internal expansion for machining

– Can be done in a time-saving manner in the side, bottom and top cover areas

Installation

– Two rows of adjustable TS 8 system holes for installation capacity

Outer space

– TS 8 accessories can be used through the TS 8 system holes

– Automatic potential balancing

– It can also be installed after the mounting plate is installed

– Fixed door position switch and door brake are optional

Wire mounting plate

– For vertically placed cabinets, the combination screw can be tightened

Hitch and lock nut for easy single? Installation

– Galvanized surface for direct connection of components and has the best quality

EMC performance

Replaceable cover plates

– Supplied with steel plates for simple machining

–Automatic potential balancing through integrated contact elements

– For quick cable entry with metal or plastic knock-off

The cover plate of the hole is in the form of an accessory.

Excellent surface protection

The three-layer treatment on the surface provides the best protection against rust.

Three stages to achieve the best quality:

1. Stage: Nano ceramic pretreatment

2. Stage: Electrophoretic primer

3. Stage: Texture - Powder Coating

Three layers of steel plate with surface treatment (Rittal standard), passed

180-hour salt spray test

Only powder-coated steel plates are sprayed, after 180 hours

Salt spray test

Integrated door hole strips

– For general purpose door panel expansion

– For the safe introduction of cables from the door to the cabinet

Replaceable door hinges

– Door hinges can be easily replaced in single-door enclosures

– Machining is required because the drilled holes are integrated and sealed

Occlusion sealing

Practical wall fixing brackets

– For quick and time-saving fixation to the cabinet from the outside

– Drill the "expansion screws" directly into the box from the outside

and from the outside with screws to fix the wall fixtures. therefrom

Transporting the expanded box to the installation site and? Need to play

Open the box and install the wall fixtures directly.

Material:

– Cabinet: steel plate

– Door: steel plate with expanded polyammonia on all sides

Ester plastic seals

Surface:

– Enclosures and doors: impregnated with primer, outer flour

End coating, texture

– Mounting plate: galvanized

Color:

  – RAL 7035

Scope of supply :

– The cabinet is closed on all sides with hinged doors

– The lid plate is at the bottom of the cabinet

– Mounting plate

– Lock: 3 mm double teeth

Pay attention to the scope of supply of specific products.

Authentication:

  – UL

  – cUL

  – CSA

  – TüV

– Lloyd's Register of Shipping in Germany

– Russia Register of Shipping

– Lloyd's Register of Shipping in United Kingdom

  – BV
Some advantages of the Rittal compact AE enclosure

More on that
Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the main technical parameters of the fuse? Answer: A. Rated voltage, B. Rated current, C. Breaking capacity, D. Melting characteristics, E. Overvoltage. What are the main products of low-voltage power distribution equipment? Answer: Low-voltage distribution panels, switch cabinets, switch boards, lighting boxes, power boxes and electrical ...

Rittal enclosures – how to determine the quality of a sheet metal enclosure cabinet Rittal enclosures – how to determine the quality of a sheet metal enclosure cabinet

1. Look at the material, you should choose a sheet metal chassis cabinet, and the steel plate must be thick, you can feel which ones are thick and which ones are thin when you knock them with your fingers. Its rugged enclosure protects the board, power supply and storage devices, and is resistant to voltage, shock, and dust.

Rittal fans – analysis of the reasons why cooling fans do not rotate Rittal fans – analysis of the reasons why cooling fans do not rotate

1. Power failure: The power supply of the fan fails, such as the power cord is disconnected, the power plug is loose, etc., which will cause the current to fail to transmit normally, resulting in the fan stopping and rotating. 2. The temperature is too low: Some heat dissipation windbreakers have a temperature protection function, when the temperature is too low, the fan will automatically ...

Rittal X SF | Helping smart logistics airports set sail safely Rittal X SF | Helping smart logistics airports set sail safely

Hello, your courier has been sent out and will be delivered tomorrow morning. Perfect logistics network, intelligent sorting, digital control ...... The development of modern logistics has made logistics services increasingly efficient and fast, and timely delivery and next-day delivery are no longer slogans.

Rittal cabinets – the role of network cabinets and how to wiring them Rittal cabinets – the role of network cabinets and how to wiring them

What is a Network Cabinet? The network cabinet is a kind of rectangular cabinet composed of two parts: frame and cover, which can install switches, optical fiber adapters, optical fiber distribution frames and other equipment in a cabinet, with electromagnetic isolation, noise isolation, ventilation and heat dissipation, anti-vibration, anti-corrosion, etc.

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

How is an electric current formed? Answer: The free electrons in the conductor move regularly and directionally under the action of the electric field force, and an electric current is formed. What are the indicators of power quality? Answer: Voltage deviation, voltage fluctuation and flicker, voltage sine wave distortion rate, frequency deviation. ...

Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets Rittal enclosures – Q&A on the basics of high- and low-voltage distribution cabinets

What is Arc? Arc is a physical phenomenon generated during the operation of electrical equipment, which is characterized by very strong light and high temperature. Classification of electrical loads? Primary load: those whose power supply interruption will cause personal injury or death; or those that will cause significant losses politically or economically. ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the common decompression starting methods of cage asynchronous motors? Answer: (1) Three-phase resistance decompression start. (2) The reactor starts under reduced pressure. (3) Autotransformer decompression start. (4) Star delta decompression start. (5) Extension ...

Rittal Cables – an introduction to the performance of industrial control cables Rittal Cables – an introduction to the performance of industrial control cables

Thermal function: Due to the existence of thermal expansion and contraction, we should also pay attention to the thermal function of industrial control cables, that is, the temperature resistance level of industrial control cables, the heating and heat dissipation characteristics of cables for power transmission at working temperatures, current carrying capacity, short circuit and overload capabilities, the thermal deformation and thermal impulse resistance of the constituent materials.

How many fault codes does a Rittal cabinet air conditioner have? How many fault codes does a Rittal cabinet air conditioner have?

There are a total of 9 fault codes for Rittal cabinet air conditioners, They are: F1, F2, F3, FF, EH, EP, EL, SF, HC. Among them, F1, F2, and F3 represent improper use or failure of internal components; FF stands for Regulation Circuit Fault; EH stands for High Temperature Fault; E ...

Rittal enclosures – how do you maintain your robot control cabinet? Rittal enclosures – how do you maintain your robot control cabinet?

1. Maintenance content (1) Check the heat dissipation of the controller It is strictly forbidden to cover the controller with plastic or other materials; Leave enough space behind and on the sides of the controller (> 120mm); It is strictly forbidden to position the controller close to the heat source; It is strictly forbidden to put sundries on the top of the controller; Avoid over-the-top ...

Rittal cabinets – what electrical components are included in the electrical cabinet? Rittal cabinets – what electrical components are included in the electrical cabinet?

1 Circuit breaker Low-voltage circuit breakers, also known as automatic air switches, can be switched on and off manually, and can be used to distribute electrical energy, start asynchronous motors infrequently, and protect power lines and motors. In the event of a severe overload, short circuit, or undervoltage fault, the circuit can be automatically shut down. 2 Contactors ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the basic requirements for a high-voltage circuit breaker? A: A. Reliable work; B. Have sufficient circuit breaking capacity C. Have the shortest possible cut-off time; D. Simple structure and low price. What is the purpose of the disconnector? Answer: A. Electrical...

Rittal at the Hannover Messe 2022 in Germany Rittal at the Hannover Messe 2022 in Germany

"In 2022, with all the challenges, especially for small and medium-sized manufacturing companies – we need to think differently: if we want to support our customers and add value in our digital transformation, it's not just a single product innovation that will change. It will combine automation, digital ...

Common faults and solutions for Rittal cabinet air conditioners Common faults and solutions for Rittal cabinet air conditioners

If the indoor temperature is higher than the outdoor one, or the indoor temperature is higher than the set temperature, the air conditioner will not start; Solution: Test the temperature comparison between indoor and outdoor to check whether the indoor temperature is too high. The voltage of the air conditioner is unstable, and the compressor cannot be started normally.

Rittal cabinets – what are the installation specifications for the cabinets? Rittal cabinets – what are the installation specifications for the cabinets?

1. The host, storage equipment, and server cabinets should be partitioned and arranged, and the host, storage equipment, server cabinets, UPS power supplies, precision air conditioners and other equipment should be set aside for maintenance according to product requirements, and the maintenance interval overlaps with adjacent equipment; 2. Enter the equipment in the computer room in stages.

What are the application areas of Rittal cabinets – cabinet air conditioners? What are the application areas of Rittal cabinets – cabinet air conditioners?

Indoor unit: suitable for all kinds of control boxes, distribution boxes and electrical cabinets in machinery, electric power, chemical industry, textile machinery, automation equipment, instrumentation and other industries with high requirements for temperature and humidity. It can also be used to regulate temperature and humidity in small spaces. Outdoor unit: suitable for outdoor general base station, outdoor ...

Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets Rittal cabinets – Q&A on the basics of high and low voltage distribution cabinets

What are the classifications of different electrical experiments according to their roles and requirements? A: It can be divided into insulation test and characteristic test. What are the factors that affect the degree of harm to the human body of electric shock? Answer: The magnitude of the current, the duration of the current, the path of the current, the resistance of the human body, and the ...

Rittal cabinet - distribution cabinet installation method, installation process and precautions Rittal cabinet - distribution cabinet installation method, installation process and precautions

First, the construction process Equipment unpacking inspection→ equipment handling, → cabinet (plate), basic installation, → above the cabinet (plate), bus preparation, → cabinet (plate), secondary circuit wiring, → cabinet (plate) test adjustment, → power transmission operation acceptance Second, the construction process 1. Equipment unpacking inspection, installation ...

Rittal air conditioner alarm code parsing Rittal air conditioner alarm code parsing

1. A01 system message: open the cabinet door Rittal air conditioner Cause: the position of the door opening and closing is incorrect; 2. A02 system message: the temperature in the cabinet is too high: the refrigeration capacity is too low or small; 3. A03 System Message: Filter Monitoring Cause: Dirty Filter Diagnosis ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top