Delixi three-phase circuit breaker classification

Create Date: 2024-8-30 12:03:23|Source: Delixi

Delixi's three-phase circuit breaker is generally divided into three types, namely 3P, 3P+N and 4P.

(1) Differences:

3P: Pure three-phase electrical equipment only uses three wirings, and in the case of no single-phase load, it trips when it is short circuited to ground or phase; Otherwise, when a one-phase N-line load is generated, the N-line circuit breaker acts as a leakage current;

3PN: After the four-wire l1l2l3n passes through the transformer coil, it can use three-phase electricity or single-phase electricity. Regardless of whether the three-phase load is balanced or not, the leakage switch will not operate; As long as there is leakage, that is, when there is a single-phase grounding or a phase-to-phase short circuit;

4P: The four-wire L12L3 passes through the transformer coil in the same way as 3PN, only 4P disconnects the N wire, and 3P retains the N wire.

                               Delixi three-phase circuit breaker classification

(2) Type

Four-pole circuit breakers are divided into four types: A, B, C, and D:

Answer: The N-pole is not equipped with an overcurrent tripper, and the N-pole is always connected together and is not closed or disconnected from the other three poles.

b: There is no overcurrent tripper at the N pole, and the N pole is connected to the other 3 poles.

The C: N pole is equipped with an overcurrent tripper, and the N pole is connected to the other 3 poles.

d: The N pole is equipped with an overcurrent tripper, and the N pole is directly connected and not closed or disconnected from the other three poles.

(3) Application:

In the case of using four poles, it is necessary to indicate which product to choose, because it is the same four poles, but whether an overcurrent releaser is installed on the N line, the function and use are different.

The overcurrent tripper is installed on the N line, which can be used for three-phase four-wire distribution lines dominated by single-phase loads, and can also be used for nonlinear loads that generate a large number of harmonics, such as gas discharge lamps, thyristor dimming, speed regulation lines and other occasions with special requirements. Generally, an N-wire circuit breaker without overcurrent tripper can be used for the equipment circuit.

In fact, although A and D are called quadrupole circuit breakers, their N-poles are always connected and do not close or disconnect with the other three poles. Therefore, this molded case circuit breaker, commonly known as "pseudo-quadrupole", is 3PN, and there is no essential difference between the three-pole molded case circuit breaker. The only thing that is more useful than a three-pole molded case circuit breaker is that in the whole cabinet, the line access may be more convenient. Therefore, this circuit breaker can only be used for three-phase loads, and only for a small number of single-phase loads (if there is a control power supply, a complete 220V system).

More on that
Working principle of linear voltage regulator - Delixi Working principle of linear voltage regulator - Delixi

1. The structure and working principle of the linear voltage regulator: A commonly used low-voltage communication regulated power supply. It consists of three parts: transformer, inductor, and capacitor divider. 2. Single-phase voltage regulator: Single...

Delixi spare parts replacement cycle Delixi spare parts replacement cycle

1. Cooling fan (2-3 years) As long as the inverter is in use, the cooling fan has always been running, so the cooling fan is generally a short-service life accessory, generally after the use of the cooling fan for 2-3 years, the bearings, balls, motors, etc. of the fan are seriously worn, and they need to be replaced.

Delixi solid state relay over AC contactor advantages Delixi solid state relay over AC contactor advantages

Delixi solid state relay and Delixi communication touch device are more used products, so what are the advantages of solid state relay compared to communication touch device, how should we choose when we can choose? 1. First of all, solid...

Brief description of power distribution appliances - Delixi Brief description of power distribution appliances - Delixi

1. The difference between power distribution appliances and control appliances Power distribution appliances: As the name suggests, it is a device that distributes electricity. Electricity, after coming out of the generator, is output by the bus, and can not be directly connected to the power equipment, and the demand is first output into the power station, which is the power distribution equipment, which is ...

Delixi voltage regulator in the case of no load stable work? Delixi voltage regulator in the case of no load stable work?

Most modern LDOs and switching regulators operate reliably under no-load conditions, and some older power devices require a minimum load to ensure stability, because one of the electrodes that needs to be compensated is affected by the payload resistance. For example, the LM1117 requires a load current of at least 1.7 mA (most ...

The component of the main line of the inverter - Delixi The component of the main line of the inverter - Delixi

An inverter is usually a device that replaces a constant voltage and frequency with a constant voltage or frequency for a variable voltage. However, in the application, the inverter will inevitably present shortcomings, and when analyzing the shortcomings of the problem, in order to deal with the shortcomings well and quickly, ...

Delixi relay maintenance method Delixi relay maintenance method

Relay is a kind of electrical appliance that turns on or off the control circuit according to the change of external input signals, such as electrical quantity (voltage, current) or non-electrical quantity (heat, time, speed, etc.), in order to complete the control or maintenance mission.

Delixi EM60 series inverter to factory settings Delixi EM60 series inverter to factory settings

First, the process of inverter rehabilitation factory value 1. Study the manual and find the corresponding function number, or key combination. 2. Confirm that the parameters can be corrected (sometimes the inverter will set the parameter to write the protection function in order to prevent the parameters from being changed randomly, and the password must be guaranteed to enter the correction) ...

Delixi integrated voltage regulator knowledge Delixi integrated voltage regulator knowledge

The role of a voltage regulator is to convert an unstable DC voltage into a stable DC voltage. However, the integrated voltage regulator has a wider and wider range of applications due to its advantages such as small size, good voltage regulation performance and perfect maintenance function. There are two types of integrated voltage regulators: linear power supply regulators and switching power supply regulators.

Voltage regulator power selection and determination - Delixi Voltage regulator power selection and determination - Delixi

1. The output power of the voltage regulator is the maximum power Basically, most of the nominal power of household appliances refers to active power, and the so-called refrigerators, air conditioners and those water pumps used in the home, etc., most of them are also inductive loads that start instantaneous currents.

Judgment and treatment of inverter short-circuit fault characteristics - Delixi Judgment and treatment of inverter short-circuit fault characteristics - Delixi

(1) Fault characteristics a) The first trip may occur during operation, but if it is restarted after resetting, it will often trip as soon as the speed is raised. b) have a large inrush current, but most drives are now able to perform maintenance trips without damage. Due to the ...

Delixi low-voltage AC contactor can not be suction reason Delixi low-voltage AC contactor can not be suction reason

AC contactor can sometimes be used for a long time can not be suction situation, although this is not a common problem of AC contactor, but AC contactor can not be suction will affect the efficiency of the operation and even damage the production equipment, with the equipment for too long, together without outstanding maintenance, are ...

Low dropout linear regulator design power supply precautions - Delixi Low dropout linear regulator design power supply precautions - Delixi

1. Pay attention to the maximum value of output current: this is a very critical parameter, the current used exceeds the maximum output current of LDO, then the voltage is unstable, and the system will fail. LDO limit parameters: The output current is considered according to the 2/3 criterion. The cost of the whole system ...

The circuit breaker is set in accordance with the principle - Delixi circuit breaker The circuit breaker is set in accordance with the principle - Delixi circuit breaker

1. When the main circuit is equipped with a total leakage maintainer, the main barrier switch, the branch barrier switch, the main circuit breaker, the branch circuit breaker or the main fuse, and the shunt fuse should also be installed. When the total leakage maintainer is a leakage circuit breaker with short-circuit, overload, and leakage maintenance functions, it can not be ...

Ways to reduce the number of inverter repairs - Delixi Ways to reduce the number of inverter repairs - Delixi

Inverter is a very ubiquitous equipment in modern workshops, this is a new type of equipment, the price is very noble, and the price of inverter repair is also very expensive, so in the process of using inverter, pay attention to the use of inverter, on the one hand, inverter, delay inverter ...

Delixi inverter load type and selection points Delixi inverter load type and selection points

The correct selection of the inverter is very important for the normal operation of the control system. When selecting an inverter, it is necessary to have a thorough understanding of the load characteristics driven by the inverter. In practice, people often divide production machinery into three types: constant torque load, constant power load and fan and pump load. ...

Delixi power transformer protection role Delixi power transformer protection role

In most large electrical systems, generators and power transformers are the two most expensive pieces of equipment. In addition to the capital cost of purchase, the continuity and reliable operation of these two key equipment systems are also the most critical. For example, the test ...

The difference between Delixi single-phase and three-phase AC voltage regulators The difference between Delixi single-phase and three-phase AC voltage regulators

Delixi's communication regulator is divided into single-phase communication regulator and three-phase communication regulator. Among them, the types of single-phase communication regulators are mainly TND, TND3, AVR, JJW-D, DBW and other types; The types of three-phase communication regulators are mainly SJW, JJW-S, SBW and so on. ...

Problems affecting the normal operation of the inverter - Delixi Problems affecting the normal operation of the inverter - Delixi

  Seriously affect the normal operation of the inverter. The core components of the inverter are IGBT power semiconductor switching components. When they are working properly, they generate a lot of heat. If there is no fan forced cooling, the sensing head will immediately detect (IGBT) overheating (IGBT) and send it ...

CDQ1F series PC-level excitation automatic transfer switch - Delixi CDQ1F series PC-level excitation automatic transfer switch - Delixi

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top